Temperature coefficients with real panels: what they change in July
Among eight panels commonly installed in SCE's Los Angeles County territory, the power temperature coefficient runs from -0.36%/°C to -0.25%/°C. In our model, the panel with the best coefficient produced 3.2% more per kW than the one with the worst in a West Covina July and 3.6% more in Lancaster, against 2.6% and 2.3% over the whole year. For a 5 kW system in West Covina that is about 218 kWh a year. Installers have been moving to better coefficients: panels better than -0.30%/°C went into 34% of new systems from January to August 2026, against 10% in 2024.
In this guide
Eight panels at three sites#
Swipe to see all columns →
| Panel | Power coefficient, %/°C | July kWh per kW, West Covina | July kWh per kW, Lancaster | Year, West Covina | Year, Valencia | Year, Lancaster |
|---|---|---|---|---|---|---|
| Q.PEAK DUO BLK ML-G10+ 410 | -0.36 | 182.9 | 188.6 | 1,706.9 | 1,810.2 | 1,940.2 |
| TSP-420 | -0.35 | 183.6 | 189.4 | 1,713.1 | 1,816.5 | 1,946.0 |
| LR5-54HABB-400M | -0.34 | 184.1 | 189.9 | 1,717.7 | 1,821.2 | 1,950.6 |
| JAM54S31-405/MR | -0.33 | 184.4 | 190.3 | 1,719.2 | 1,823.0 | 1,952.4 |
| SIL-440QD | -0.29 | 185.2 | 191.5 | 1,721.0 | 1,825.7 | 1,955.2 |
| ELNSM54M-HC-N-450 | -0.29 | 185.1 | 191.5 | 1,719.5 | 1,824.2 | 1,953.8 |
| Q.TRON BLK M-G2.H+ 430 | -0.28 | 187.5 | 193.9 | 1,742.4 | 1,847.9 | 1,976.7 |
| REC460AA Pure-RX | -0.25 | 188.7 | 195.3 | 1,750.5 | 1,856.8 | 1,985.3 |
Output per kW of panel rating, 10 panels facing south at 20°, typical-year weather at ZIP 91790 (West Covina), 91355 (Valencia) and 93535 (Lancaster). Each panel is modeled from its CEC parameters, including its temperature coefficients, with a standard inverter; the differences also include each panel's low-light behavior, not only temperature. Sorted from the most negative coefficient. Source: Cali-Graf engine; CEC module list.
- July widens the gap. Hot cells cost the most power when the sun is strongest, so the spread between panels is larger in July than over the year at every site. - The site matters more than the panel. Lancaster gave the highest output of the three sites in July and over the year for every panel; the coefficient changes the ranking of panels, not of places. - The ranking mostly follows the coefficient. The two panels with the least negative coefficients, REC Pure-RX and Qcells Q.TRON, produced the most per kW at every site, but in the middle of the table other panel properties matter as much: the Elin panel, with a better coefficient than the Silfab, made slightly less.
What installers chose#
Swipe to see all columns →
| Year of permission to operate | Systems with a known panel | Better than −0.30%/°C | −0.30 to −0.35%/°C | −0.35%/°C or worse |
|---|---|---|---|---|
| 2024 | 15,549 | 10% | 44% | 46% |
| 2025 | 15,010 | 16% | 46% | 38% |
| 2026 (Jan–Aug) | 10,683 | 34% | 37% | 29% |
New residential solar systems in SCE's service territory in Los Angeles County by year of permission to operate, by the power temperature coefficient of the panel recorded on each system (the most numerous panel when several are listed), from the CEC module list; 96% of systems had a panel found in the list. Source: California DG Stats; CEC module list.
- Better coefficients are spreading. Panels at -0.35%/°C or worse fell from 46% of systems in 2024 to 29% from January to August 2026, while panels better than -0.30%/°C rose to 34%.
What it means for the proposal#
- Small, but every year. The best panel in the table made 2.3% to 2.6% more in a year than the worst, more in summer; most, but not all, of that comes from the coefficient. - Compare per kW, not per panel. A panel with a better coefficient but a lower rating may still produce less per panel; the per-kW figures above compare like with like. - Use the panel's own coefficient. A production estimate that uses one default coefficient for every panel hides this difference; the Cali-Graf engine uses each panel's CEC data.
Data limits#
The modeled differences between panels include low-light performance and other CEC model parameters, not only the temperature coefficient. All panels are modeled facing south at 20°, with the roof-mount cell temperature model of PVWatts that the engine uses. The standard inverter in the model caps output at the panels' rating divided by 1.2, which trims the better panel's peaks slightly: at the panels themselves, before the inverter, the West Covina gap is 2.9% a year and 3.5% in July. The installed mix depends on matching recorded panel names to the CEC list; unmatched systems are left out.
How much does a panel's temperature coefficient matter in Southern California?
In our model, the best of eight common panels made 3.2% more per kW than the worst in a West Covina July and 2.6% more over the year.
What is a good temperature coefficient for solar panels?
Among panels installed in Los Angeles County, -0.25%/°C was the best in our table and -0.36%/°C the worst; in 2026, 34% of new systems used panels better than -0.30%/°C.
Do panels produce less in July than in spring?
Per hour of sun, yes: hot cells lose power, and the loss is larger for panels with more negative coefficients.
Methodology#
The Cali-Graf engine models each panel hour by hour with the CEC single-diode model from the panel's CEC parameters and its cell temperature, using NSRDB typical-year weather for each ZIP; output is divided by the panels' rated kW. The installed mix uses DG Stats records for SCE, Los Angeles County, residential, new systems with solar, permission to operate from January 1, 2024 to August 31, 2026, with each system's panel matched exactly to the CEC module list. Rounded half up.
Sources#
- California Energy Commission — Solar Equipment Lists, PV modules. https://solarequipment.energy.ca.gov/
- California Distributed Generation Statistics — Interconnected Project Sites data set. https://www.californiadgstats.ca.gov/downloads/
- NLR — National Solar Radiation Database (NSRDB), typical meteorological year. https://nsrdb.nlr.gov/
How to cite this page#
Cali-Graf. “Temperature coefficients with real panels: what they change in July.” cali-graf.com, updated Nov 18, 2026. https://cali-graf.com/guides/temperature-coefficients-with-real-panels-what-they-change-in/