Round-trip efficiency in practice: what the spec sheet leaves out
Battery datasheets quote round-trip efficiency on different bases, so the numbers are not directly comparable. Tesla rates Powerwall 3 at 89% from solar through the battery to the home; Tesla Powerwall 2, Enphase's IQ Battery 5P and 10C and FranklinWH's aPower 2 are rated at 90% from AC in to AC out; Enphase also gives 96% on the DC side; SolarEdge gives a "peak" 94.5%. Tesla and FranklinWH state their figures new, at about 3 kW and 25 °C; Enphase states only the power level, half of rated power, and SolarEdge states no conditions. None of these datasheets states the battery's standby consumption. On the bill, the efficiency matters less than it looks: in our model of a 9,000 kWh-a-year home on SCE's Net Billing Tariff, each point of round-trip efficiency was worth about $7 a year for a 13.5 kWh battery.
In this guide
How each maker states it#
Swipe to see all columns →
| Battery | Stated efficiency | Measured from | Conditions stated |
|---|---|---|---|
| Tesla Powerwall 3 | 89% | Solar to battery to home or grid | Typical solar shifting; 25 °C; 3.3 kW charge and discharge; beginning of life |
| Tesla Powerwall 2 | 90% | AC to battery to AC | 25 °C; 3.3 kW charge and discharge; beginning of life |
| Enphase IQ Battery 5P | 90% AC; 96% DC | AC to battery to AC | At 50% of rated power |
| Enphase IQ Battery 10C | 90% AC; 96% DC | AC to battery to AC | At 50% of rated power |
| FranklinWH aPower 2 | 90% | Grid to battery to load | Beginning of life; 3 kW charge and discharge; 25 °C |
| SolarEdge Home Battery 400V | 94.5% | Peak round trip | Not stated beyond "peak" |
Round-trip efficiency as each datasheet states it, with the footnoted conditions: Tesla Powerwall 3 Datasheet (2025) and Powerwall 2 Datasheet; Enphase IQ Battery 5P (DSH-00010-6.0) and 10C (DSH-00565-2.0) data sheets; FranklinWH aPower 2 datasheet; SolarEdge Home Battery 400V datasheet (DS-000167-NAM).
What the figures leave out#
- The starting point. "Solar to battery to home" includes the inverter's conversion of solar power; "AC to battery to AC" starts from power that has already been converted; "DC round trip" leaves out the battery's own inverter. The same battery has a higher DC figure than AC figure, as Enphase shows with 96% against 90%. - Power level and temperature. Tesla and FranklinWH measured at about 3 kW and 25 °C, Enphase at half of rated power; efficiency at other power levels and temperatures is not stated. - Age. Tesla and FranklinWH give their figures at beginning of life; Enphase and SolarEdge do not say, and none states the efficiency of an aged battery. - Standby use. None of these datasheets gives a standby or idle consumption figure for the battery, although it is a loss on top of the round trip. - "Peak." A peak efficiency is the best point on the curve, not an average over a day.
What a point is worth#
- About $7 a year per point. In our model the battery saved $1,178 a year at 85% round-trip efficiency, $1,216 at 90% and $1,252 at 95%: the ten points were worth $73 a year. - Small next to the reserve. In our battery-modes guide, raising the backup reserve from 20% to 50% cut the yearly saving from $1,208 to $890; efficiency differences between brands move it by tens of dollars.
Data limits#
One modeled home and battery on one tariff in 2027, with the battery charging only from solar and not exporting stored energy; the engine applies the efficiency as a constant, split between charge and discharge, without standby losses, temperature or aging. The datasheets were read as dated above.
What is a good round-trip efficiency for a home battery?
The batteries here are rated at 90% AC to AC, or 89% from solar to home for Powerwall 3; compare figures only on the same basis.
Why is Powerwall 3's efficiency lower than Powerwall 2's?
It is measured from solar, including the conversion from DC panel power to AC; Powerwall 2's figure starts from AC power that has already been converted.
How much does battery efficiency change my savings?
In our model, about $7 a year per point of efficiency for a 13.5 kWh battery on SCE's Net Billing Tariff.
Methodology#
Each efficiency figure and its footnoted conditions were checked word for word in the datasheets named under the table. The Cali-Graf engine billed the home (9,000 kWh a year, 5.49 kW of solar facing south at ZIP 91790, Net Billing Tariff with TOU-D-PRIME at SCE rates of October 1, 2026) for 2027 with a 13.5 kWh battery in time-of-use mode, charging only from solar and not selling stored energy to the grid, changing only the round-trip efficiency from 85% to 95%. Rounded half up.
Sources#
- Tesla — Powerwall 3 Datasheet (2025). https://energylibrary.tesla.com/docs/Public/EnergyStorage/Powerwall/3/Datasheet/en-us/Powerwall-3-Datasheet.pdf
- Tesla — Powerwall 2 Datasheet (North America). https://energylibrary.tesla.com/docs/Public/EnergyStorage/Powerwall/2/Datasheet/en-us/Powerwall-2-Datasheet.pdf
- Enphase — IQ Battery 5P data sheet, DSH-00010-6.0 (May 28, 2024), distributor copy. https://signaturesolar.com/content/documents/Enphase/Battery/IQ%20Battery-5P-DSH-00010-2.0-EN-US-2023-07-26%20(1).pdf
- Enphase — IQ Battery 10C data sheet, DSH-00565-2.0 (February 19, 2025), distributor copy. https://ressupply.com/documents/enphase/IQBATTERY-10C-1P-NA_Data_Sheet.pdf
- FranklinWH — aPower 2 Datasheet. https://www.franklinwh.com/document/apower-2-datasheet
- SolarEdge — SolarEdge Home Battery 400V for North America, datasheet DS-000167-NAM (March 5, 2024).
How to cite this page#
Cali-Graf. “Round-trip efficiency in practice: what the spec sheet leaves out.” cali-graf.com, updated Nov 19, 2026. https://cali-graf.com/guides/round-trip-efficiency-in-practice-what-the-spec-sheet/