Microinverters vs string inverters vs optimizers in 2026, with LA County install share
The inverter market in SCE's Los Angeles County territory turned over in two years. Tesla Powerwall 3, a battery with its own solar inverter, was the only inverter on 44% of new home solar systems from January to August 2026, up from 4% in 2024. SolarEdge, with optimizers on each panel and a central inverter, fell from 50% of new systems in 2020 to 7%. Microinverters peaked at 57% in 2023 and were down to 37% in 2026. Classic string inverters without optimizers stayed a small niche throughout. The shift follows the battery: 81% of new systems in 2026 had one, against 15% in 2023, and Powerwall 3 is solar inverter and battery in one box.
In this guide
Share of new systems by inverter type#
Swipe to see all columns →
| Year of permission to operate | New systems | Microinverters | SolarEdge optimizers | Tesla Powerwall 3 | Other Tesla inverters | Other string or hybrid | More than one type |
|---|---|---|---|---|---|---|---|
| 2020 | 9,424 | 43% | 50% | 0% | 0% | 7% | 0% |
| 2021 | 13,810 | 48% | 44% | 0% | 4% | 5% | 0% |
| 2022 | 22,016 | 52% | 41% | 0% | 5% | 3% | 0% |
| 2023 | 27,746 | 57% | 34% | 0% | 4% | 5% | 0% |
| 2024 | 16,252 | 53% | 32% | 4% | 3% | 6% | 3% |
| 2025 | 15,594 | 42% | 16% | 29% | 2% | 4% | 7% |
| 2026 (Jan–Aug) | 11,096 | 37% | 7% | 44% | 1% | 4% | 8% |
New residential solar systems in SCE's service territory in Los Angeles County by year of permission to operate and the inverter type on record. Microinverters: inverters under 1 kW in the CEC list, or Enphase, APsystems, Hoymiles and SunPower AC modules. Other Tesla inverters: Tesla's string solar inverters, used with Powerwall 2 and Powerwall+. "More than one type": most often Powerwall 3 together with another solar inverter. Additions to existing systems are not included. Source: California DG Stats; CEC inverter list in the Cali-Graf engine.
Why Powerwall 3 took over#
- Battery and inverter in one. In 2026 every Powerwall 3 system had a battery by definition, while 59% of microinverter systems and 72% of SolarEdge systems had one. A design that needs a battery anyway saves the separate solar inverter. - One unit takes most homes' solar. Powerwall 3 takes up to 20 kW DC of panels on 6 inputs and delivers up to 11.5 kW AC; the design details are in our Powerwall 3 design guide. - SolarEdge's battery path is narrower. The SolarEdge Home Battery is DC-coupled and works only with a SolarEdge Home Hub inverter, so a SolarEdge design with a battery is tied to that inverter family.
What each architecture means for design#
- Microinverters. One inverter per panel, so each panel works on its own and clipping is set panel by panel; in our clipping guide, new microinverter systems ran a median DC/AC ratio of 1.25. Enphase batteries are AC-coupled and sized against the microinverters' output. - Optimizers with a central inverter (SolarEdge). Each panel has its own optimizer; the inverter is shared. A battery needs a Home Hub inverter. - Powerwall 3. Panels are wired in strings to its 6 inputs; string length is limited by voltage in the cold and current per input, and rooftop strings need Tesla's Mid-Circuit Interrupters for rapid shutdown. - String inverters without optimizers. Rare in new home systems here.
Data limits#
DG Stats records the inverter models on each interconnection application; the type is assigned from the model, and a few unmatched models are classed by manufacturer. The records show new systems in SCE's Los Angeles County territory only, by year of permission to operate, not by permit date. 2026 covers January to August.
Are microinverters or string inverters more common in Southern California?
In SCE's Los Angeles County territory in 2026, Tesla Powerwall 3, a battery with a string-style solar inverter, was the most common at 44% of new systems, ahead of microinverters at 37% and SolarEdge at 7%.
Why did SolarEdge's share fall?
In the records, SolarEdge went from 50% of new systems in 2020 to 34% in 2023, while microinverters rose to 57% and only 15% of new systems had a battery; then, as batteries spread and Powerwall 3 rose to 44%, it fell to 7% in 2026.
Do I need a battery with microinverters?
No; in 2026, 59% of new microinverter systems in the records had one.
Methodology#
California DG Stats' Interconnected Project Sites (data through August 31, 2026): SCE, Los Angeles County, residential, new systems with solar (not expansions), permission to operate from January 1, 2020 to August 31, 2026. Each inverter on a record was classed: Tesla model 1707000 as Powerwall 3; SolarEdge as optimizers; other Tesla inverters separately; microinverters by a rated output under 1 kW in the CEC inverter list or by manufacturer; the rest as string or hybrid. Shares are rounded half up.
Sources#
- California Distributed Generation Statistics — Interconnected Project Sites data set. https://www.californiadgstats.ca.gov/downloads/
- California Energy Commission — Solar Equipment Lists, grid support inverters. https://solarequipment.energy.ca.gov/
- Tesla — Powerwall 3 Datasheet (2025). https://energylibrary.tesla.com/docs/Public/EnergyStorage/Powerwall/3/Datasheet/en-us/Powerwall-3-Datasheet.pdf
- SolarEdge — SolarEdge Home Battery 400V for North America, datasheet DS-000167-NAM (March 5, 2024).
- Enphase — Planning the Enphase Energy System, technical brief TEB-00004-8.0 (July 2026). https://enphase.com/download/planning-enphase-energy-system-tech-brief
How to cite this page#
Cali-Graf. “Microinverters vs string inverters vs optimizers in 2026, with LA County install share.” cali-graf.com, updated Nov 19, 2026. https://cali-graf.com/guides/microinverters-vs-string-inverters-vs-optimizers-in-2026-with/