DC-coupled vs AC-coupled storage under net billing
On an SCE Net Billing bill, DC coupling is worth about $9 a year over AC coupling for a 13.5 kWh battery in a typical home. Tesla rates Powerwall 3, a DC-coupled battery, at 89% from solar through the battery to the home; measured from the inverter's output, as the solar is in our model, that is 91.3%. The common AC-coupled batteries, Powerwall 2, Enphase IQ Battery 5P and FranklinWH aPower 2, are rated at 90% round trip. In our model of a 9,000 kWh-a-year home with 5.49 kW of solar, the DC-coupled battery saved $1,225 a year and the AC-coupled one $1,216; with battery exports in the best hours the gap was $12. The choice between them turns on the existing solar, the equipment and the price, not on efficiency.
In this guide
The modeled bills#
Swipe to see all columns →
| Battery connection | Round trip for solar energy | Bill with solar and battery | Battery saves a year | Saves with battery exports | kWh bought | kWh exported |
|---|---|---|---|---|---|---|
| DC-coupled (Powerwall 3) | 91.3% | $952 | $1,225 | $1,316 | 2,413 | 2,100 |
| AC-coupled battery, 90% round trip | 90.0% | $962 | $1,216 | $1,304 | 2,439 | 2,076 |
One modeled home on SCE's Net Billing Tariff with TOU-D-PRIME, 2027 at SCE rates of October 1, 2026: 9,000 kWh a year, 5.49 kW of solar facing south at ZIP 91790, a 13.5 kWh battery charging at up to 5 kW from solar only, time-of-use mode with a 20% reserve; the only difference between the rows is the round-trip efficiency. With solar and no battery the bill is $2,177. "With battery exports": the battery may also export in the hours when the export price is above the price of a kWh bought. Source: Cali-Graf engine.
Why the gap is small#
- Only stored solar is affected. Coupling changes the losses on energy that goes through the battery; solar used directly in the home or exported goes through a solar inverter either way. The battery stores a few thousand kWh a year, and a 1.3% difference in efficiency on that is a few dozen kWh: the AC-coupled home bought 26 kWh more a year. - Ten years of the difference is about $95 at today's rates. - Tesla's own case for DC is broader. Tesla says it strongly prefers solar wired straight into Powerwall 3 because it needs less equipment, costs less and is more efficient; in SCE's Los Angeles County territory, 81% of new Powerwall 3 systems since 2024 had no other solar inverter on record.
When coupling does matter#
- Existing solar. A battery added to a home with working solar is AC-coupled by default; replacing the old inverter only to gain DC efficiency would not pay back on these numbers. - Backup limits. AC-coupled solar is limited in the backup circuit, at most 7.68 kW AC per Powerwall in Tesla's rules, and Enphase limits microinverter output relative to the batteries; DC-coupled solar on Powerwall 3 is checked against its own DC input limit instead. In an outage, Tesla says, a Powerwall facing more than 5 kW of excess AC-coupled solar will shift the frequency to cut the solar back and may shut it down completely. - Clipping. A DC-coupled battery can in principle store solar power above the inverter's AC limit; the model does not include this, and in the records 10% of single-Powerwall 3 systems with all solar wired into it had more kW DC of panels than its 11.5 kW AC output, so they could clip on the brightest hours.
Data limits#
The model holds the solar production identical in both rows and changes only the battery's round-trip efficiency; it does not model inverter efficiency differences between brands, standby consumption, or clipping recapture. The 91.3% figure is Tesla's 89% solar-to-battery-to-home efficiency divided by its 97.5% solar-to-home efficiency, a derived figure, not one Tesla publishes; the 90% figures are each maker's AC-to-battery-to-AC ratings at beginning of life. One home, one year, one tariff. In our battery-modes guide the engine applied Tesla's 89% directly, which is why its time-of-use saving is slightly lower.
Is DC-coupled storage more efficient than AC-coupled?
Slightly: about 91.3% against 90% for energy that goes through the battery, in our reading of the datasheets.
How much does DC coupling save on an SCE net billing bill?
About $9 a year for a 13.5 kWh battery in our modeled home, or $12 with battery exports.
Should I replace my solar inverter to DC-couple a new battery?
Not for efficiency alone: the gain is about $95 over ten years in our model.
Methodology#
The Cali-Graf engine bills the home hour by hour for 2027 at SCE rates of October 1, 2026 and the latest export price table, on the Net Billing Tariff with TOU-D-PRIME, with the battery simulated in time-of-use mode (caligraf/battery/simulate.py): 13.5 kWh usable, 5 kW charge from solar only, 11.5 kW discharge, 20% reserve. The DC case uses 91.3% (89% ÷ 97.5% from the Powerwall 3 datasheet); the AC case uses 90% from the Powerwall 2, IQ Battery 5P and aPower 2 datasheets. Rounded half up.
Sources#
- Tesla — Powerwall 3 Datasheet (2025). https://energylibrary.tesla.com/docs/Public/EnergyStorage/Powerwall/3/Datasheet/en-us/Powerwall-3-Datasheet.pdf
- Tesla — Powerwall 2 Datasheet (North America). https://energylibrary.tesla.com/docs/Public/EnergyStorage/Powerwall/2/Datasheet/en-us/Powerwall-2-Datasheet.pdf
- Tesla — Powerwall 3 System Design: AC-Coupled Solar System Sizing. https://energylibrary.tesla.com/docs/Public/EnergyStorage/Powerwall/3/SystemDesign/en-us/GUID-23D242D1-8D65-47B9-9118-57002FFD84D2.html
- Enphase — IQ Battery 5P data sheet, DSH-00010-6.0 (May 28, 2024), distributor copy. https://signaturesolar.com/content/documents/Enphase/Battery/IQ%20Battery-5P-DSH-00010-2.0-EN-US-2023-07-26%20(1).pdf
- FranklinWH — aPower 2 Datasheet. https://www.franklinwh.com/document/apower-2-datasheet
- Southern California Edison — Schedules NBT and TOU-D. https://www.sce.com/regulatory/regulatory-information/tariff-books/rates-pricing-choices
How to cite this page#
Cali-Graf. “DC-coupled vs AC-coupled storage under net billing.” cali-graf.com, updated Nov 18, 2026. https://cali-graf.com/guides/dc-coupled-vs-ac-coupled-storage-under-net-billing/