Cali-GrafCali-Graf
ReferenceBatteriesSCENet billingSettings

Battery operating modes for SCE net billing: self-consumption, TOU and reserve

Cali-Graf · Published Nov 18, 2026 · Data as of Oct 1, 2026

Under SCE's Net Billing Tariff, a battery saves money by keeping midday solar for the evening, when a kWh bought costs the most and a kWh exported earns least. Most of that saving comes simply from using the battery at all. In our model, a 13.5 kWh battery added to a home of 9,000 kWh a year with 5.49 kW of solar saves $1,201 a year in self-consumption mode and $1,208 in time-of-use mode. Letting it export in the few hours when the export price beats the retail price raises that to $1,294. The setting that costs most is the backup reserve: keeping 50% of the battery for outages instead of 20% cuts the saving to $890, and a battery left in backup-only mode saves nothing.

$1,208
Yearly saving of the battery in time-of-use mode
Modeled home with solar, 2027
$1,294
Same, with exports in the best hours
Battery exports allowed
$890
Same, with a 50% backup reserve
Time-of-use mode
In this guide
The modesWhat each setting savesWhat to set upData limitsQuestionsMethodologySourcesHow to cite this page

The modes#

- Self-consumption. The battery charges from solar the home does not use and discharges whenever the home needs more than the solar makes, down to the reserve. - Time-of-use. During the day, until the peak, the battery holds its charge for the evening peak and discharges only what the peak will not need; in and after the peak it covers the home. - Exports in the best hours. In time-of-use mode the battery can also send energy to the grid in the hours when the export price, with the ACC Plus adder, is above the price of a kWh bought, keeping enough for the home's remaining peak hours. On SCE's latest export price table those hours fall mainly on late-summer evenings. - Backup only. The battery stays full for outages and does not change the bill.

Model the battery settings for the customer
Cali-Graf bills the home hour by hour with the battery in each mode and builds the customer proposal.
Open Cali-Graf

What each setting saves#

Battery modeBill with solar and batteryBattery saves a yearkWh boughtkWh exported
Backup only$2,177$05,7485,741
Self-consumption$976$1,2012,4592,057
Time-of-use$969$1,2082,4592,057
Time-of-use, no reserve$808$1,3691,8411,366
Time-of-use, battery exports in the best hours$883$1,2942,5882,186
Time-of-use, 50% reserve$1,287$8903,5963,331

One modeled home of 9,000 kWh a year (NLR ResStock profiles of SCE baseline region 9) with 5.49 kW of south-facing solar at ZIP 91790 and a Tesla Powerwall 3 (13.5 kWh, 20% backup reserve unless stated), billed for 2027 on the Net Billing Tariff and TOU-D-PRIME at SCE's rates of October 1, 2026. "Battery saves" is against the same home with solar and no battery, $2,177 a year. Source: Cali-Graf engine.

Download this table (CSV)

- Self-consumption against time-of-use. The two modes come out close: on TOU-D-PRIME, most of the value is in covering the 4 to 9 p.m. peak, and both modes do that. Over the year both modes buy and export the same energy, 2,459 kWh and 2,057 kWh; only the hours differ. - Exports. Exporting from the battery adds less than a tenth to the saving, because the hours that pay are few. In the model the battery sold 129 kWh a year, all in August and September. - The reserve. The reserve matters more than the mode: every kWh held for outages is a kWh not covering the evening peak. With no reserve, the same battery saves $1,369 a year, and nothing is held for outages.

What to set up#

- Default to time-of-use. Use time-of-use or self-consumption with the lowest reserve the customer is comfortable with. - Hours to export. Turn on exports from the battery only where the equipment and the interconnection allow it. - Backup-only mode. Explain that a battery in backup-only mode is insurance, not savings.

Data limits#

The model assumes the battery knows each day's load and solar; real battery apps forecast them and do somewhat worse. Results are for one modeled home and one battery; a home that uses more in the evening saves more. The model charges the battery only from solar, never from the grid. Whether a battery may export depends on the system's interconnection configuration, which is not modeled here. Battery wear is not included.

What is the best battery mode for SCE net billing?

In our model, time-of-use and self-consumption save about the same, $1,208 and $1,201 a year; letting the battery export in the best evening hours adds a little more, $1,294 in all.

Does a higher backup reserve cost money?

Yes: in the model, a 50% reserve cut the yearly saving from $1,208 to $890, because the reserved energy is not used to cover the evening peak.

Does a battery in backup mode lower the bill?

No: a battery that only stays charged for outages does not change the bill.

Methodology#

The Cali-Graf engine bills the same modeled home for 2027 hour by hour on the Net Billing Tariff and TOU-D-PRIME, at SCE's rates of October 1, 2026 and the latest export price table, with the battery dispatched each hour by the selected mode (the engine's battery simulator) and losses at the battery's round-trip efficiency. Amounts are rounded half up.

Sources#

  1. Southern California Edison — Schedule NBT and Schedule TOU-D (TOU-D-PRIME). https://www.sce.com/regulatory/regulatory-information/tariff-books/rates-pricing-choices
  2. Tesla — Powerwall 3 datasheet. https://www.tesla.com/powerwall
  3. NLR — ResStock 2025 Release 1. https://registry.opendata.aws/nrel-pds-building-stock/

How to cite this page#

Cali-Graf. “Battery operating modes for SCE net billing: self-consumption, TOU and reserve.” cali-graf.com, updated Nov 18, 2026. https://cali-graf.com/guides/battery-modes-sce-net-billing/