Cali-GrafCali-Graf
GuideBatteriesBackupOutagesSizing

Battery backup sizing: loads, kWh and a realistic outage day

Cali-Graf · Published Nov 18, 2026 · Data as of Nov 18, 2026

The simple rule, battery kWh divided by average load, flatters a home battery in the months when outages hurt most. A 9,000 kWh-a-year home averages 1.03 kW, so a 13.5 kWh battery "should" last about 13 hours. Hour by hour, in our model, a full battery runs that home through an outage starting at 6 p.m. for a median 5 hours in August, when evening air conditioning drives the load, against 15 hours in January. Solar refills it only in the cooler months: with 5.49 kW of panels the battery lasted three days on 18% of December evenings and on none in August. And if the battery is already down to its 20% reserve when the outage comes, only 2.7 kWh is left: one or two hours.

5
Hours a full 13.5 kWh battery runs the home, August evening outage
Median, no solar
15
Same in January
Median, no solar
2.7
Energy left at the default 20% reserve
When the outage comes after the evening peak
In this guide
Hours of backup, by monthWhat the numbers say for sizingData limitsQuestionsMethodologySourcesHow to cite this page

Hours of backup, by month#

Outage starting at 6 p.m. inFull battery, no solar: hoursFull battery with solar: hours (72 = 3 days or more)Evenings lasting 3 days with solarBattery at 20% reserve, with solar: hours
January153610%2
February15364%2
March167274%2
April121313%2
May133732%2
June780%1
July550%1
August550%1
September660%1
October880%1
November15330%1
December163718%2

Median hours a 13.5 kWh battery (Tesla Powerwall 3) runs the whole home in an outage starting at 6 p.m. on each day of the month, counted up to 72 hours. The home: the average hourly use of NLR ResStock homes of SCE's inland valleys, 9,000 kWh a year. With solar: 5.49 kW south-facing at ZIP 91790; during the outage solar serves the home first and charges the battery with the rest, up to the battery's charge rate. Reserve: the battery starts at its 20% backup reserve. Source: Cali-Graf engine.

Download this table (CSV)

Size the battery on the customer's own hours
Cali-Graf uses the home's hourly load and the roof's solar to size storage and build the proposal.
Open Cali-Graf

What the numbers say for sizing#

- Size for the summer evening, not the average. In June to October the load from 6 to 10 p.m. is 1.8 to 2.5 times the average, and a single 13.5 kWh battery covers a whole home for less than a working day. - Cut the loads, not only add batteries. A partial backup panel that leaves out air conditioning, an EV charger and a pool pump keeps the battery for the loads that matter in an outage. - Solar refill is a winter-and-spring benefit. In the cooler months the battery lasts through the first night, the panels refill it, and a whole-home outage can be ridden out for days. In summer the battery runs out first: a full one lasts about 5 hours from 6 p.m., and the house is then without power for about 9 hours until the panels cover the load again. The panels are not the limit: in July the home used about 50% of their output directly, and the midday surplus, 15.5 kWh a day, is more than the battery holds. Whether a battery that has run empty restarts on solar depends on the equipment; the model stops at the first hour it cannot cover. - The reserve is the only guaranteed backup. In time-of-use mode the battery in our model still held a median 82% to 100% of its charge at 6 p.m. and 39% to 76% at 9 p.m., but it runs down to the reserve overnight and can start a cloudy evening there. Customers who care most about backup should raise the reserve, at a cost on the bill (in our guide to battery modes on SCE net billing, a 50% reserve cut the battery's yearly saving from $1,208 to $890).

Data limits#

The home is an average of modeled homes, so its hour-to-hour peaks are smoother than a real home's; a real home with a large air conditioner will empty the battery sooner. The model assumes the battery can carry every hour's load and keeps no power for starting motors; it does not model a backup panel or loads turned off by the customer. Solar output is a typical year, not a stormy day. Outages that start at other hours give different results.

How long will a Powerwall-size battery run my house?

In our model of a typical Los Angeles County home, a full battery lasted a median 5 hours in an August evening outage and 15 hours in January; the summer figure is short because of evening air conditioning.

Will solar recharge my battery during an outage?

Yes, if the system is set up for backup, but in summer a full battery runs out before sunrise; in the model, a full battery with 5.49 kW of solar lasted three days on 18% of December evenings and on none in August.

Does the backup reserve matter?

Yes: it is the only energy always kept for an outage; once the battery has covered the evening and the night, it is all that is left. At the default 20% reserve, a 13.5 kWh battery holds 2.7 kWh, one or two hours for this home.

Methodology#

The Cali-Graf engine's hourly load (the average of 30 NLR ResStock homes of SCE baseline region 9, scaled to 9,000 kWh) and its solar model (south at 20°, NSRDB typical-year weather at ZIP 91790) give each hour of the year; for an outage starting at 6 p.m. local time on each day, the battery covers the load until it is empty, recharging from solar output above the load at up to its charge rate, with round-trip losses split between charge and discharge. Medians are over the days of each month.

Sources#

  1. Tesla — Powerwall 3 datasheet. https://www.tesla.com/powerwall
  2. NLR — ResStock 2025 Release 1 and NSRDB. https://registry.opendata.aws/nrel-pds-building-stock/

How to cite this page#

Cali-Graf. “Battery backup sizing: loads, kWh and a realistic outage day.” cali-graf.com, updated Nov 18, 2026. https://cali-graf.com/guides/battery-backup-sizing-outage-day/