Average home solar system size by city in Los Angeles County's SCE territory, 2025
The typical new home solar system that SCE connected in Los Angeles County in 2025 was 6.2 kW AC — about 6.8 kW in the DC panel rating that quotes use. Half of the 15,594 systems fell between 4.0 and 8.7 kW AC. By city, the median ran from 3.3 kW in Gardena to 11.1 kW in Calabasas. A battery makes the biggest difference: systems with one had a median of 6.8 kW AC, the 3,369 without one 3.3 kW.
In this guide
System size by city#
Swipe to see all columns →
| City | Median kW AC | ≈ kW DC | Middle half | With battery | Median with battery | Systems, 2025 |
|---|---|---|---|---|---|---|
| Agoura Hills | 9.4 | 10.3 | 6.9–12.6 | 90% | 9.4 | 132 |
| Alhambra | 4.9 | 5.4 | 3.2–6.8 | 60% | 5.9 | 113 |
| Arcadia | 5.8 | 6.4 | 3.3–9.8 | 56% | 8.5 | 306 |
| Baldwin Park | 4.6 | 5.1 | 3.2–6.7 | 73% | 5.5 | 102 |
| Bellflower | 6.2 | 6.8 | 4.3–8.0 | 79% | 6.6 | 121 |
| Calabasas | 11.1 | 12.1 | 8.5–14.0 | 88% | 11.1 | 112 |
| Canyon Country | 7.8 | 8.6 | 6.0–10.4 | 94% | 7.8 | 246 |
| Carson | 5.5 | 6.0 | 3.9–7.4 | 80% | 5.7 | 322 |
| Castaic | 6.7 | 7.3 | 4.0–9.7 | 87% | 6.9 | 214 |
| Cerritos | 7.5 | 8.2 | 5.6–9.4 | 90% | 7.6 | 136 |
| Claremont | 7.3 | 8.0 | 5.3–9.5 | 89% | 7.3 | 146 |
| Compton | 3.8 | 4.1 | 3.0–5.4 | 53% | 5.0 | 240 |
| Covina | 6.3 | 7.0 | 3.9–8.8 | 75% | 7.3 | 277 |
| Diamond Bar | 8.3 | 9.1 | 6.0–10.9 | 86% | 8.0 | 138 |
| Downey | 7.0 | 7.6 | 4.7–9.2 | 88% | 7.1 | 173 |
| El Monte | 3.4 | 3.7 | 2.9–5.5 | 42% | 5.9 | 225 |
| Gardena | 3.3 | 3.6 | 2.2–5.6 | 52% | 5.1 | 143 |
| Glendora | 7.3 | 8.0 | 4.9–10.0 | 85% | 7.8 | 169 |
| Hacienda Heights | 6.6 | 7.2 | 4.5–9.3 | 76% | 7.0 | 162 |
| Hawthorne | 5.4 | 5.9 | 4.2–6.9 | 90% | 5.6 | 106 |
| Inglewood | 5.2 | 5.7 | 3.7–7.3 | 82% | 6.0 | 119 |
| La Canada | 9.5 | 10.5 | 7.0–12.3 | 88% | 9.8 | 114 |
| La Mirada | 6.2 | 6.8 | 4.8–8.0 | 87% | 6.4 | 147 |
| La Puente | 6.4 | 7.0 | 4.7–8.1 | 84% | 6.6 | 219 |
| La Verne | 7.7 | 8.4 | 5.6–10.4 | 81% | 8.3 | 147 |
| Lakewood | 6.2 | 6.8 | 4.5–7.9 | 88% | 6.3 | 229 |
| Lancaster | 5.2 | 5.7 | 3.0–8.0 | 83% | 6.0 | 1,657 |
| Long Beach | 6.2 | 6.8 | 4.4–8.1 | 84% | 6.5 | 833 |
| Los Angeles | 4.9 | 5.4 | 3.4–7.1 | 72% | 6.0 | 265 |
| Malibu | 7.7 | 8.4 | 4.8–11.5 | 78% | 7.8 | 117 |
| Manhattan Beach | 6.4 | 7.1 | 3.9–9.1 | 67% | 7.5 | 132 |
| Monrovia | 5.5 | 6.1 | 3.3–8.4 | 68% | 7.2 | 149 |
| Montebello | 3.9 | 4.3 | 2.9–6.7 | 61% | 5.2 | 119 |
| Monterey Park | 5.9 | 6.5 | 4.0–7.7 | 79% | 6.3 | 118 |
| Norwalk | 5.6 | 6.1 | 4.1–7.1 | 94% | 5.7 | 245 |
| Palmdale | 6.8 | 7.5 | 4.9–9.1 | 88% | 7.1 | 1,108 |
| Pico Rivera | 6.0 | 6.6 | 3.9–7.9 | 79% | 6.5 | 165 |
| Pomona | 5.2 | 5.8 | 3.2–7.4 | 68% | 6.3 | 472 |
| Rancho Palos Verdes | 7.9 | 8.6 | 5.9–10.7 | 89% | 7.9 | 177 |
| Redondo Beach | 5.0 | 5.5 | 3.3–7.5 | 63% | 6.5 | 179 |
| Rosemead | 3.8 | 4.1 | 2.9–5.9 | 54% | 5.7 | 162 |
| Rowland Heights | 7.0 | 7.7 | 5.2–8.7 | 85% | 7.2 | 117 |
| San Dimas | 7.3 | 8.1 | 4.9–10.3 | 80% | 8.2 | 113 |
| San Gabriel | 6.3 | 7.0 | 4.4–8.9 | 75% | 7.2 | 158 |
| Santa Clarita | 6.1 | 6.7 | 4.9–9.3 | 93% | 6.3 | 685 |
| Santa Monica | 6.0 | 6.6 | 4.4–7.9 | 59% | 6.9 | 110 |
| Saugus | 8.3 | 9.1 | 6.4–10.3 | 94% | 8.3 | 136 |
| Temple City | 4.7 | 5.2 | 2.9–8.2 | 62% | 7.2 | 104 |
| Torrance | 5.9 | 6.5 | 4.1–7.5 | 91% | 5.9 | 296 |
| Valencia | 7.3 | 8.0 | 4.4–9.0 | 58% | 8.1 | 374 |
| Walnut | 4.2 | 4.6 | 3.3–8.1 | 47% | 8.1 | 223 |
| West Covina | 6.7 | 7.4 | 4.0–9.1 | 73% | 7.7 | 268 |
| Westlake Village | 9.6 | 10.5 | 6.7–14.1 | 92% | 9.4 | 123 |
| Whittier | 5.9 | 6.5 | 4.0–7.7 | 75% | 6.5 | 426 |
New residential solar systems connected by SCE in 2025 in the 54 cities with at least 100 of them, by the city written on the interconnection record. Median and middle half (25th to 75th percentile) of System Size AC, the CEC-AC rating. ≈ kW DC — the median multiplied by 1.10, the typical ratio of panel DC rating to CEC-AC rating in this territory (see below). With battery — share of the city's systems with storage capacity listed; median with battery — the median size of those systems. Source: California DG Stats, data through Aug 31, 2026.
Download this table (CSV) · Download every city on the records (CSV)
The medians differ by more than three to one across the territory. 10 cities had a median below 5 kW AC and 6 had one above 8 kW. Part of the gap is batteries: Gardena, at the bottom, had a battery on 52% of its systems, Calabasas on 88%. But the gap holds among battery systems alone, from 5.0 kW AC in Compton to 11.1 kW in Calabasas. The data does not record house size or electricity use, so it shows how big systems are in each city, not why.
Cities are as written on the records. Santa Clarita, Valencia, Saugus and Canyon Country appear separately although they are parts of one city, and “Los Angeles” is the mailing city on records inside SCE's territory — in 2025 most often ZIP codes 90056, 90063 and 90022 (Ladera Heights and East Los Angeles areas), followed by South Los Angeles ZIP codes such as 90047, 90044, 90001 and 90061. The full list of 119 city names is in the download.
Reading a quote in kW DC against these numbers#
SCE reports a system's size as its CEC-AC rating: the number of panels times each panel's PTC rating times the inverter's efficiency, which the application calculates for listed equipment. Quotes and panel spec sheets use the DC rating at standard test conditions, which is higher. To compare, multiply the AC figures here by about 1.1: on 9,781 systems connected in 2025 whose panel model and count match the California Energy Commission module list, the DC rating was a median 1.10 times the CEC-AC rating, and half of them fell between 1.09 and 1.11. A median system of 6.2 kW AC is therefore about 6.8 kW DC.
With and without a battery#
Swipe to see all columns →
| New systems, 2025 | Median kW AC | ≈ kW DC | Middle half | Systems |
|---|---|---|---|---|
| All new systems | 6.2 | 6.8 | 4.0–8.7 | 15,594 |
| With battery | 6.8 | 7.5 | 4.9–9.2 | 12,225 |
| Without battery | 3.3 | 3.6 | 2.9–5.3 | 3,369 |
| Owned by the homeowner | 6.0 | 6.6 | 3.4–8.7 | 8,095 |
| Leased or PPA | 6.3 | 6.9 | 4.5–8.8 | 7,499 |
New residential solar systems connected by SCE in Los Angeles County in 2025. With battery — storage capacity listed on the record. Owned and leased or PPA — the Third Party Owned field; systems without an answer are in neither row. Source: California DG Stats, data through Aug 31, 2026.
Systems with a battery were twice the size of those without one in 2025, and 66% of the systems without a battery were under 4 kW AC. Ownership made little difference: owned systems had a median of 6.0 kW AC, leased and PPA systems 6.3 kW.
Part of the solar-only group is likely new-home solar. DG Stats has no field for new construction, but since 2020 California's building standards have required solar on new homes, sized to the home's expected annual electricity use, and 106 of the 2025 systems without a battery name Lennar Homes as the owner. To check a quote for a solar-and-battery retrofit, compare it with the with-battery figures.
Size over time#
Swipe to see all columns →
| Year | New systems | Median kW AC | Middle half | With battery | Without battery | Share with battery |
|---|---|---|---|---|---|---|
| 2019 | 9,394 | 5.4 | 3.8–7.3 | 6.5 | 5.2 | 10% |
| 2020 | 9,424 | 5.5 | 3.8–7.5 | 6.9 | 5.3 | 12% |
| 2021 | 13,810 | 6.1 | 4.2–8.1 | 7.5 | 5.8 | 15% |
| 2022 | 22,016 | 6.3 | 4.5–8.5 | 7.8 | 6.2 | 13% |
| 2023 | 27,746 | 6.6 | 4.7–8.7 | 7.5 | 6.5 | 15% |
| 2024 | 16,252 | 5.5 | 3.7–7.9 | 6.3 | 4.3 | 55% |
| 2025 | 15,594 | 6.2 | 4.0–8.7 | 6.8 | 3.3 | 78% |
| 2026 (Jan–Aug) | 11,096 | 6.1 | 4.0–9.1 | 6.9 | 3.3 | 81% |
New residential solar systems connected by SCE in Los Angeles County by year of Permission to Operate; NEM expansion records left out. 2026 covers Jan 1 – Aug 31. Source: California DG Stats, data through Aug 31, 2026.
The median grew from 5.4 kW AC in 2019 to 6.6 kW in 2023, fell to 5.5 kW in 2024 and recovered to 6.2 kW in 2025; January–August 2026 is at 6.1 kW. The 2024 drop coincides with the switch to the Net Billing Tariff, which applies to interconnection applications submitted on or after April 15, 2023: 6% of new systems connected in 2023 were on it and 71% in 2024. In the same years the battery share rose from 15% of new systems in 2023 to 55% in 2024 and 78% in 2025, while the median system without a battery fell from 6.5 kW AC to 4.3 kW and then 3.3 kW. Systems with a battery went from 7.5 kW in 2023 to 6.3 kW in 2024 and 6.8 kW in 2025.
Size a system for a real home#
A city median is a starting point, not a design. Size a system from the home's own usage and roof with the solar production calculator, then model the battery under the Net Billing Tariff in the Cali-Graf app. For how many systems in this territory carry a battery, see the battery attach rate page.
Data limits#
The data covers SCE's service territory only; the City of Los Angeles, Burbank, Glendale, Pasadena and other municipal utilities are not in DG Stats. Sizes are the CEC-AC rating reported to SCE. SCE's DC field is not used: the DG Stats Data Key says SCE does not review or validate DC sizes, and on many records it repeats the AC value. The DC conversion comes from systems whose panel count and model match the CEC module list and give a DC rating between 1.0 and 1.35 times the AC rating — 63% of 2025 systems. NEM expansion records, which add capacity to an existing system, are left out: 524 in 2025. The mean, 6.9 kW AC in 2025, sits above the median because a few large systems pull it up — 19 residential systems were above 30 kW AC. SCE does not validate the city on a record. DG Stats updates existing records quarterly, so recent months can still change.
What is the average home solar system size in Los Angeles County?
In SCE's part of the county, the median new residential system connected in 2025 was 6.2 kW AC, about 6.8 kW DC; the mean was 6.9 kW AC. Systems with a battery had a median of 6.8 kW AC.
Is this kW DC or kW AC?
AC — the CEC-AC rating that SCE records. Multiply by about 1.1 for the DC rating in a quote; the table's ≈ kW DC column does this for each city.
Why are systems without a battery so small?
In 2025 they were a minority — 3,369 of 15,594 — and the group includes solar that California requires on new homes, sized to the home's expected annual use. The data does not mark new construction, so the two cannot be separated.
Does this include the City of Los Angeles?
No. The City of Los Angeles is served by LADWP, which does not report to DG Stats. “Los Angeles” in the table is the mailing city on records inside SCE's territory.
Methodology#
The population is every record in the California DG Stats Interconnected Project Sites data set for SCE (data through Aug 31, 2026; files dated Oct 9, 2026) with Service County “Los Angeles”, Customer Sector “Residential” and a Technology Type that includes photovoltaic, counted by the year of App Approved Date, the date SCE issued Permission to Operate. Records whose Interconnection Program contains “Expansion” are left out, as are records without a positive System Size AC. Size is System Size AC. Medians and middle halves are the 50th, 25th and 75th percentiles (inclusive method). Cities are the Service City text in capitals, trimmed; the page table lists cities with at least 100 systems in 2025, and the download lists every city, with medians where a city has at least 10 systems. The DC/AC ratio uses 2025 systems where every Generator Model entry, other than a battery, matches one wattage on the California Energy Commission PV Module List (data as of Oct 1, 2026), comparing letters, digits and plus signs, with and without bracketed text and an AC-module suffix; DC = Generator Quantity × Nameplate Pmax, summed; systems are kept when DC is 1.0 to 1.35 times AC.
Sources#
- California Distributed Generation Statistics — Interconnected Project Sites data set, data through Aug 31, 2026. https://www.californiadgstats.ca.gov/downloads/
- California DG Stats — Interconnected Project Sites Data Key (Nov 4, 2026): System Size Fields (SCE System Size AC = CEC AC Nameplate Rating; System Size DC not reviewed or validated) and Service City. https://www.californiadgstats.ca.gov/downloads/
- California Energy Commission — Solar Equipment Lists: PV Module List (Nameplate Pmax), data as of Oct 1, 2026. https://www.energy.ca.gov/programs-and-topics/programs/solar-equipment-lists
- California Energy Commission — 2019 Building Energy Efficiency Standards, Frequently Asked Questions: solar photovoltaic systems required for new homes, sized to the home's expected annual electric needs. https://www.energy.ca.gov/sites/default/files/2020-03/Title_24_2019_Building_Standards_FAQ_ada.pdf
- California Public Utilities Commission — Net Billing Tariff: applies to interconnection applications submitted on or after April 15, 2023. https://www.cpuc.ca.gov/industries-and-topics/electrical-energy/demand-side-management/customer-generation/nem-revisit/net-billing-tariff
How to cite this page#
Cali-Graf. “Average home solar system size by city in Los Angeles County's SCE territory, 2025.” cali-graf.com, updated Nov 10, 2026. https://cali-graf.com/guides/average-solar-system-size-los-angeles-county-sce/