Cali-GrafCali-Graf
CalculatorElectrificationEVHeat pumpsSCE

Electrification load: adding an EV and a heat pump to a solar design

Cali-Graf · Published Nov 18, 2026 · Data as of Oct 1, 2026

An electric vehicle adds a predictable load whose cost depends on when it charges. A heat pump in Los Angeles County adds little electricity, and in many homes saves some, unless the home had no air conditioning. In NLR's ResStock model, Los Angeles County single-family homes with an EV charge a median 1,922 kWh a year. On a modeled SCE home with solar sized before the car, that load adds $582 a year if the car charges at night, but only $143 if it charges at midday, when the solar would otherwise be exported for a few cents. Replacing a gas furnace and a central air conditioner with a heat pump lowered yearly use by a median 465 kWh, because the new unit cools more efficiently. In a home that had no air conditioning, the heat pump adds cooling and a median 4,212 kWh a year.

1,922
Median yearly EV charging, LA County single-family homes with an EV
ResStock model
$0.07
Cost per kWh of midday EV charging with solar
Against night charging in the table
4,212
Extra yearly use when a heat pump brings cooling to a home without AC
Median, gas-heated homes
In this guide
An electric vehicleA heat pumpData limitsQuestionsMethodologySourcesHow to cite this page

An electric vehicle#

EV chargedAdded to the bill without solarAdded with solar sized before the EVAdded with solar resized for the EV
ResStock timing$779$607$466
Night, 9 p.m. to 6 a.m.$703$582$444
Midday, 10 a.m. to 3 p.m.$648$143−$3

One modeled home of 9,000 kWh a year (the average hourly shape of 30 NLR ResStock homes of SCE baseline region 9) plus a car charging 1,922 kWh a year, the same every day. ResStock timing: the share of charging by hour of the day of ResStock's Los Angeles County homes with an EV. Bills for 2027 at SCE's rates of October 1, 2026: without solar on TOU-D-4-9PM; with solar on the Net Billing Tariff and TOU-D-PRIME. Solar sized before the EV: 5.49 kW south-facing at ZIP 91790; resized: 6.66 kW, for the home and the car. Charging hours are standard time; in summer, on the clock, each window starts and ends an hour later (night 10 p.m. to 7 a.m., midday 11 a.m. to 4 p.m.). Source: Cali-Graf engine; NLR ResStock 2025 Release 1.

Download this table (CSV)

A kWh of charging at night cost the home with solar $0.30: it is bought from SCE at off-peak prices. A kWh charged at midday cost $0.07: most of it comes from solar that would otherwise have been exported for a few cents. ResStock's own charging times, 30% of them in the late afternoon and evening, cost $0.32 per kWh. A system resized for the car takes the night-charging cost down to $444 a year; with midday charging, the resized system covers the car entirely.

Among the 403 modeled homes with an EV, the middle half charge between 813 and 3,095 kWh a year; a design should use the customer's own driving where it is known.

Add the car and the heat pump to the design
Cali-Graf bills the home hour by hour with the new loads, before and after solar, and builds the customer proposal.
Open Cali-Graf

A heat pump#

Cooling beforeShare of these homesChange in kWh a yearHeatingCoolingSolar for the added kWh, kW
Central air conditioning68%−465+297−3950.0
Room air conditioners7%+2,065+355+1,2951.3
No air conditioning26%+4,212+384+3,2692.6

Los Angeles County single-family homes heated by natural gas, in ResStock's scenario that replaces the heating and cooling with a ducted air-source heat pump: the median change in yearly electricity by the cooling the home had before, and the median change in heating and cooling electricity. The total also includes fans and pumps, so heating and cooling do not add up to it. Solar for the added kWh at 1,638 kWh per kW a year, south-facing at ZIP 91790. Source: NLR ResStock 2025 Release 1, upgrade 4.

Download this table (CSV)

Los Angeles County winters are mild: across the 4,953 gas-heated homes in the scenario, heating added a median 323 kWh of electricity a year and replaced 38 therms of gas. What drives the change is cooling. In the 68% of homes that had central air conditioning, the heat pump replaces an older, less efficient unit, and yearly use goes down. In the 26% that had none, the heat pump brings cooling for the first time, and yearly use rises by about as much as 2.6 kW of solar makes. The highest winter day's peak rose by a median 0.25 kW.

Data limits#

The EV example uses one average home and the same charging every day; real cars charge more on some days than others, and a car that is away at midday cannot charge from solar. The heat pump figures are ResStock's model of one heat pump type on its homes and 2018 weather, as medians across homes; they are not measured results, and a home that adds cooling may use it more or less than the model assumes. Bills include no city tax or Climate Credit. The SCE plan for the EV case is TOU-D-PRIME with solar, the plan of Net Billing homes; SCE also has a separately metered EV option, not modeled here.

How much electricity does an electric vehicle add to a home in Los Angeles County?

In NLR's ResStock model, a median 1,922 kWh a year for the county's single-family homes with an EV; the middle half charge 813 to 3,095 kWh.

Should an EV charge at night or at midday with solar under net billing?

At midday, when the car is home: in the model, a kWh charged at midday cost $0.07, against $0.30 at night, because midday charging uses solar that would otherwise be exported for a few cents.

Does a heat pump increase electricity use in Los Angeles?

It depends on the cooling it replaces. Replacing a gas furnace and a central air conditioner, the median home used 465 kWh a year less; in a home without air conditioning, it used 4,212 kWh more, because the heat pump also cools.

Methodology#

EV: the yearly EV charging of ResStock 2025 Release 1's Los Angeles County single-family homes with an EV (upgrade 0), and the hour-of-day share of their modeled charging. The bill example: the Cali-Graf engine, given a year of hourly load (the average shape of 30 ResStock homes of SCE baseline region 9, scaled to 9,000 kWh) with the charging added, bills 2027 at SCE's rates of October 1, 2026, without and with solar, SCE generation, no city tax. Heat pump: ResStock 2025 Release 1, upgrade 4 ("Typical Cold Climate Ducted Air Source Heat Pump"), against the homes as they are, for Los Angeles County single-family homes heated by natural gas where the upgrade applies; medians of each home's change. Amounts are rounded half up.

Sources#

  1. NLR — ResStock 2025 Release 1, metadata and annual results, California, upgrades 0 and 4. https://registry.opendata.aws/nrel-pds-building-stock/
  2. Southern California Edison — Schedule TOU-D and Schedule NBT. https://www.sce.com/regulatory/regulatory-information/tariff-books/rates-pricing-choices

How to cite this page#

Cali-Graf. “Electrification load: adding an EV and a heat pump to a solar design.” cali-graf.com, updated Nov 18, 2026. https://cali-graf.com/guides/adding-ev-heat-pump-to-solar-design/