72 cells. Power classes 265–400 W in the CEC list; datasheet covers 370–395 W.

CEC listed · Feb 11, 2020UL 170310-yr product + 25-yr performance warranty
Power class
  • Power (STC)370 WCEC nameplate
  • Efficiency≥18.6%datasheet minimum
  • %/°C Pmax−0.39CEC test: −0.370
  • Degradation / yr0.68%after year 1 (warranty)

Power classes

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation · ZNShine Solar datasheet · 27 models
ModelPmaxVoc, VIsc, AVmp, VImp, AEfficiencyPTC
ZXM6-72-265/M265 W44.148.2235.807.40≈13.3%232 W
ZXM6-72-270/M270 W44.398.3336.007.50≈13.6%237 W
ZXM6-72-275/M275 W44.648.4436.207.60≈13.8%241 W
ZXM6-72-280/M280 W45.018.5236.507.67≈14.1%246 W
ZXM6-72-285/M285 W45.388.5636.607.78≈14.3%250 W
ZXM6-72-290/M290 W45.778.5936.807.88≈14.6%255 W
ZXM6-72-295/M295 W46.008.6237.007.97≈14.8%259 W
ZXM6-72-300/M300 W46.198.6637.208.06≈15.1%264 W
ZXM6-72-305/M305 W46.268.7337.508.13≈15.3%268 W
ZXM6-72-310/M310 W46.368.8237.728.22≈15.6%278 W
ZXM6-72-315/M315 W46.458.9137.868.32≈15.8%283 W
ZXM6-72-320/M320 W46.548.9937.968.43≈16.1%287 W
ZXM6-72-325/M325 W46.639.0938.068.54≈16.3%292 W
ZXM6-72-330/M330 W46.729.1938.158.65≈16.6%296 W
ZXM6-72-340/M340 W46.309.4238.128.92≈17.1%316 W
ZXM6-72-345/M345 W46.509.5138.349.00≈17.4%321 W
ZXM6-72-350/M350 W46.659.6138.469.10≈17.6%326 W
ZXM6-72-355/M355 W47.609.6638.909.13≈17.9%328 W
ZXM6-72-360/M360 W47.709.8039.109.21≈18.1%333 W
ZXM6-72-365/M365 W48.009.8439.309.29≈18.4%338 W
ZXM6-72-370/M370 W48.209.9139.509.37≥18.6%342 W
ZXM6-72-375/M375 W48.409.9839.709.45≥18.9%347 W
ZXM6-72-380/M380 W48.6010.0339.909.53≥19.1%352 W
ZXM6-72-385/M385 W48.8010.0940.109.61≥19.4%357 W
ZXM6-72-390/M390 W49.0010.1640.309.68≥19.6%361 W
ZXM6-72-395/M395 W49.2010.2240.509.76≥19.9%366 W
ZXM6-72-400/M400 W49.4010.2840.709.83≈20.1%371 W
≈ efficiency = Pmax ÷ panel area 1.988 m² (datasheet size) for classes outside the datasheet.

Build & dimensions

ZNShine Solar datasheet · Cali-Graf calculation · CEC PV Module List (Oct 7, 2026)

Heat & cold behaviour

ZNShine Solar datasheet · CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation
DatasheetCEC listing test
Pmax coefficient γ−0.39 %/°C−0.370 %/°C
Voc coefficient β−0.29 %/°C−0.272 %/°C
Isc coefficient α+0.05 %/°C+0.043 %/°C
Vmp coefficient≈ −0.44 %/°C—
Operating cell temperatureNMOT 45 ± 2 °CNOCT 45.5 °C
Vmp coefficient ≈ γ − α (datasheet); used only for the hot-roof voltage estimate.

At normal operating conditions (NMOT, 800 W/m²) — datasheet

ClassPmax, WVoc, VIsc, AVmp, VImp, A
370 W273.744.608.0136.507.51
375 W277.844.808.0636.607.59
380 W281.144.908.1036.907.62
385 W284.845.108.1537.107.67
390 W288.345.308.2137.307.72
395 W292.145.508.2637.507.78

Away from lab conditions — CEC listing test points

ClassPmax at NOCTVmp × Imp at NOCTPmax at 200 W/m²Low-light efficiency vs STC
265 W187.8 W32.03 V × 5.86 A51 W96%
270 W191.4 W32.21 V × 5.94 A52 W96%
275 W195.1 W32.39 V × 6.02 A53 W96%
280 W198.5 W32.66 V × 6.08 A53.9 W96%
285 W201.9 W32.74 V × 6.17 A54.8 W96%
290 W205.6 W32.92 V × 6.25 A55.8 W96%
295 W209.1 W33.1 V × 6.32 A56.8 W96%
300 W212.6 W33.28 V × 6.39 A57.7 W96%
305 W216.2 W33.55 V × 6.44 A58.7 W96%
310 W219.8 W33.75 V × 6.51 A59.7 W96%
315 W223.3 W33.87 V × 6.59 A60.6 W96%
320 W226.9 W33.96 V × 6.68 A61.6 W96%
325 W230.5 W34.05 V × 6.77 A62.6 W96%
330 W234 W34.13 V × 6.86 A63.5 W96%
340 W255.2 W36.12 V × 7.07 A66.8 W98%
345 W258.9 W36.32 V × 7.13 A67.8 W98%
350 W262.6 W36.44 V × 7.21 A68.7 W98%
355 W263.6 W35.71 V × 7.38 A70.5 W99%
360 W267.3 W35.89 V × 7.45 A71.5 W99%
365 W271 W36.07 V × 7.51 A72.5 W99%
370 W274.7 W36.26 V × 7.58 A73.5 W99%
375 W278.5 W36.44 V × 7.64 A74.5 W99%
380 W282.2 W36.62 V × 7.71 A75.5 W99%
385 W286 W36.81 V × 7.77 A76.5 W99%
390 W289.6 W36.99 V × 7.83 A77.4 W99%
395 W293.4 W37.17 V × 7.89 A78.4 W99%
400 W297 W37.36 V × 7.95 A79.4 W99%
Pmax = Vmp × Imp from the CEC listing; low-light efficiency = Pmax at 200 W/m² ÷ (20% of STC Pmax).

Electrical & strength ratings

Warranty & degradation

ZNShine Solar datasheet

Independent reliability testing

Kiwa PVEL Scorecard
8
PVEL Scorecards
ZNShine Solar named Top Performer, 2016–2026
This exact series is not listed in published PVEL Top Performer tables. Results below are for the manufacturer.

Inverter compatibility & string sizing

ZNShine Solar datasheet · Cali-Graf calculation · NLR PVWatts v8 · CEC PV Module List (Oct 7, 2026) · inverter datasheets · NLR SAM inverter library · CEC Grid Support Inverter List (Oct 7, 2026)
51.4 V
Voc when cold
per panel
31 V
Vmp when hot
per panel
11
Max panels / string
max DC 600 V
2
Min panels / string
MPPT from 60 V
Defaults come from NLR TMY weather (coldest hour, hottest modeled cell). Code calculations (NEC 690.7) use the ASHRAE extreme annual minimum, which is usually colder — enter it above.

String inverters most named in SoCal permits

InverterMax DC inputMPPTWindow sourcePanels per string
Tesla 1538000-xx-y600 V60–480 Vdatasheet2–11
Solis (Ginlong) S6-EH1P10K-H-US600 V80–520 Vdatasheet3–11
Solis (Ginlong) Solis-1P7.6K-4G-US600 V100–500 Vdatasheet4–11
Qcells Q.VOLT H7.6SX498 V234–498 VCEC test window8–9

Microinverters (one per panel)

MicroinverterRecommended module powerMax DC inputMPPTVoc cold / Vmp hotCheckDC/AC
Enphase IQ8PLUS-72-2-US235–440 W60 V29–45 V51.4 / 31 V✓ Within range1.28
Enphase IQ8X-80-M-US320–540 W79.5 V43–60 V51.4 / 31 V✗ Not a match: module voltage below MPPT range0.97
APsystems (Alt Power System) DS3-L265–570 W60 V28–45 V51.4 / 31 V✓ Within range0.47
Enphase IQ8M-72-2-US260–460 W60 V30–45 V51.4 / 31 V✓ Within range1.14
Enphase IQ8A-72-2-US295–500 W60 V32–45 V51.4 / 31 V⚠ Works; below MPPT at peak heat1.06
Voltage check against the microinverter datasheets — confirm the pairing on the manufacturer’s module compatibility list. Rows appear only when the panel’s power is inside the microinverter’s recommended module power range.
SolarEdge and other optimizer-based systems size strings by the optimizer rules — use the manufacturer’s designer. Reference inverters: most named in SoCal permits since Oct 2024.

Expected production in Southern California

NLR PVWatts v8 · Cali-Graf calculation
CitykWh / kW / yrkWh / panel / yrkWh / system / yrSun, kWh/m²/day
Los Angeles1,67662011,7826.08
Palmdale1,83567912,9006.69
Chula Vista1,69662811,9236.11
Huntington Beach1,64360811,5505.89
Riverside1,69662811,9236.21
Santa Clarita1,72463812,1206.28
769Jan770Feb988Mar1,091Apr1,078May1,145Jun1,206Jul1,220Aug1,067Sep941Oct809Nov700DeckWh per month · Los Angeles
Estimate for comparison, not a quote: shading, roof orientation and local losses change real output. Roof mount, 20° tilt, south, 14% system losses.

Compare with similar 370 W panels

CEC PV Module List (Oct 7, 2026) · Kiwa PVEL Scorecard · Canadian Solar datasheet · building permits
PanelPmaxEfficiencyγ Pmax (CEC)Voc, VIsc, APVEL (product / brand)SoCal permits (series)
ZNShine Solar ZXM6-72-370/M370 W≥18.6%−0.37048.29.91brand 8×—
LONGi LR4-60HPB-370M370 W≈20.9%−0.33941.211.5product 2021, 2022193
Canadian Solar CS3N-375MS {Blk}375 W≈19%−0.34243.511.2product 202346
REC Group REC370AA370 W≈21.9%−0.25844.110.55brand 9× (2016–2025)30
Same fields from the same sources for every row; ≈ efficiency is calculated from the listed area. Comparable series: other brands, same product group, power range covering this class.

Questions & answers

How efficient is the ZNShine Solar ZXM6-72-370/M?

The ZNShine Solar datasheet guarantees at least 18.6% module efficiency for the 370 W class (up to 19.9% for 395 W). 370 W over 1.99 m² equals about 186 W per square meter.

How much energy does one panel produce in Los Angeles or Palmdale?

PVWatts v8 with typical-year weather gives about 620 kWh per year per 370 W panel in Los Angeles and about 679 kWh in Palmdale (20° roof, facing south, 14% system losses).

How much power does it lose on a hot roof?

With γ = −0.39 %/°C, at a 77 °C cell temperature (hottest modeled hour in Palmdale) output is about 20.2% below the STC rating.

How many panels fit on one string?

With the Tesla 1538000-xx-y (max DC 600 V, MPPT from 60 V, datasheet) in Los Angeles the calculator gives 2–11 panels per string (Voc at 2 °C = 51.4 V, Vmp at 74 °C cell = 31 V). Final design must follow the inverter manual and NEC 690.7.

Does it work with Enphase IQ8PLUS-72-2-US microinverters?

Voltage check against the Enphase datasheet: Voc when cold 51.4 V vs max input 60 V; Vmp when hot 31 V vs MPPT low 29 V; recommended module power 235–440 W. Confirm on the microinverter maker’s compatibility list.

What does the warranty cover?

10 years on the product and 25 years on performance (manufacturer datasheet).

How big and heavy is it?

78.1 × 39.4 × 1.38 in (1,984 × 1,002 × 35 mm), 48.5 lb (22 kg).

Has this panel been reliability-tested?

This exact series is not in published PVEL Top Performer tables; ZNShine Solar was named a Top Performer in 8 Scorecards (2016–2026).

Sources

  1. California Energy Commission — Solar Equipment Lists, PV Module List, Inverter List (snapshot Oct 7, 2026).
  2. ZNShine Solar — manufacturer datasheet “ZXM6-72 Series Znshinesolar 5BB Monocrystalline PV Module”.
  3. Canadian Solar — manufacturer datasheet “HiKu Mono PERC CS3N-400|405|410|415|420|425MS MORE POWER”.
  4. Kiwa PVEL — PV Module Reliability Scorecard, Top Performer lists 2016–2026.
  5. NLR (formerly NREL) — System Advisor Model CEC inverter library (version 2026.7.3).
  6. NLR (formerly NREL) — PVWatts v8, NSRDB PSM v3 typical-year weather for Los Angeles, Palmdale, Chula Vista, Huntington Beach, Riverside, Santa Clarita.
  7. Inverter datasheets — APsystems (Alt Power System), Enphase, Solis (Ginlong), Tesla (manufacturer documents).
  8. Building permits — Southern California permit portals. Equipment matched from permit descriptions.
  9. Cali-Graf calculations — formulas and inputs are shown next to each calculated value (efficiency from area, temperature-corrected voltages, string sizing, energy estimates).