Solar panelZNShine Solar

ZNShine Solar ZXM6-60-305/M

60 cells. Power classes 225–330 W in the CEC list.

CEC listed · Feb 11, 2020UL 1703
Power class
  • Power (STC)305 WCEC nameplate
  • Efficiency≈18.5%calculated from area
  • %/°C Pmax−0.356CEC listing test
  • PTC / STC92.1%PTC 281 W (CEC)

Power classes

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation · 20 models
ModelPmaxVoc, VIsc, AVmp, VImp, AEfficiencyPTCCEC listed
ZXM6-60-225/M225 W37.008.0729.707.58≈13.7%198 W—
ZXM6-60-230/M230 W37.108.2229.907.70≈14.1%202 W—
ZXM6-60-235/M235 W37.808.2530.207.78≈14.4%207 W—
ZXM6-60-240/M240 W37.908.4030.307.92≈14.7%211 W—
ZXM6-60-245/M245 W38.108.5930.408.07≈15.0%216 W—
ZXM6-60-250/M250 W38.208.7130.508.20≈15.3%220 W—
ZXM6-60-255/M255 W38.308.8330.608.34≈15.6%225 W—
ZXM6-60-260/M260 W38.408.9530.728.46≈15.9%233 W—
ZXM6-60-265/M265 W38.509.0730.848.59≈16.2%238 W—
ZXM6-60-270/M270 W38.609.1730.978.72≈16.5%242 W—
ZXM6-60-285/M285 W38.599.5931.858.95≈17.4%264 WFeb 11, 2020
ZXM6-60-290/M290 W38.869.6632.169.02≈17.7%269 WFeb 11, 2020
ZXM6-60-295/M295 W39.509.6532.309.14≈17.9%271 WFeb 11, 2020
ZXM6-60-300/M300 W39.709.7532.509.24≈18.2%276 WFeb 11, 2020
ZXM6-60-305/M305 W39.909.8532.709.33≈18.5%281 WFeb 11, 2020
ZXM6-60-310/M310 W40.109.9532.909.43≈18.8%286 WFeb 11, 2020
ZXM6-60-315/M315 W40.3010.0533.109.52≈19.1%290 WFeb 11, 2020
ZXM6-60-320/M320 W40.5010.1533.309.61≈19.4%295 WFeb 11, 2020
ZXM6-60-325/M325 W40.7010.2533.509.71≈19.7%300 WOct 21, 2020
ZXM6-60-330/M330 W40.9010.3533.709.80≈20.0%305 WOct 21, 2020
≈ efficiency = Pmax ÷ CEC-listed area 1.64 m².

Build & dimensions

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation

Heat & cold behaviour

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation
CEC listing test
Pmax coefficient γ−0.356 %/°C
Voc coefficient β−0.269 %/°C
Isc coefficient α+0.043 %/°C
Operating cell temperatureNOCT 47.4 °C
Vmp coefficient ≈ γ − α (CEC); used only for the hot-roof voltage estimate.

Away from lab conditions — CEC listing test points

ClassPmax at NOCTVmp × Imp at NOCTPmax at 200 W/m²Low-light efficiency vs STC
225 W159.6 W26.57 V × 6.01 A43.3 W96%
230 W163.2 W26.75 V × 6.1 A44.3 W96%
235 W166.6 W27.02 V × 6.17 A45.2 W96%
240 W170.2 W27.11 V × 6.28 A46.2 W96%
245 W173.9 W27.2 V × 6.4 A47.2 W96%
250 W177.3 W27.29 V × 6.5 A48.1 W96%
255 W180.9 W27.38 V × 6.61 A49.1 W96%
260 W184.3 W27.48 V × 6.7 A50 W96%
265 W187.8 W27.59 V × 6.81 A51 W96%
270 W191.5 W27.71 V × 6.91 A52 W96%
285 W212.2 W29.76 V × 7.13 A55.7 W98%
290 W215.9 W30.05 V × 7.18 A56.7 W98%
295 W222.8 W30.26 V × 7.36 A59.7 W101%
300 W226.6 W30.45 V × 7.44 A60.7 W101%
305 W230.2 W30.64 V × 7.51 A61.7 W101%
310 W234.1 W30.82 V × 7.6 A62.7 W101%
315 W237.8 W31.01 V × 7.67 A63.7 W101%
320 W241.5 W31.2 V × 7.74 A64.7 W101%
325 W245.5 W31.39 V × 7.82 A65.8 W101%
330 W249.2 W31.57 V × 7.89 A66.8 W101%
Pmax = Vmp × Imp from the CEC listing; low-light efficiency = Pmax at 200 W/m² ÷ (20% of STC Pmax).

Independent reliability testing

Kiwa PVEL Scorecard
8
PVEL Scorecards
ZNShine Solar named Top Performer, 2016–2026
This exact series is not listed in published PVEL Top Performer tables. Results below are for the manufacturer.

Inverter compatibility & string sizing

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation · NLR PVWatts v8 · inverter datasheets · NLR SAM inverter library · CEC Grid Support Inverter List (Oct 7, 2026)
42.4 V
Voc when cold
per panel
26.3 V
Vmp when hot
per panel
14
Max panels / string
max DC 600 V
3
Min panels / string
MPPT from 60 V
Defaults come from NLR TMY weather (coldest hour, hottest modeled cell). Code calculations (NEC 690.7) use the ASHRAE extreme annual minimum, which is usually colder — enter it above. β is the CEC-measured coefficient; NEC 690.7 calculations use the datasheet value.

String inverters most named in SoCal permits

InverterMax DC inputMPPTWindow sourcePanels per string
Tesla 1538000-xx-y600 V60–480 Vdatasheet3–14
Solis (Ginlong) S6-EH1P10K-H-US600 V80–520 Vdatasheet4–14
Solis (Ginlong) Solis-1P7.6K-4G-US600 V100–500 Vdatasheet4–14
Qcells Q.VOLT H7.6SX498 V234–498 VCEC test window9–11

Microinverters (one per panel)

MicroinverterRecommended module powerMax DC inputMPPTVoc cold / Vmp hotCheckDC/AC
Enphase IQ8PLUS-72-2-US235–440 W60 V29–45 V42.4 / 26.3 V⚠ Works; below MPPT at peak heat1.05
APsystems (Alt Power System) DS3-L265–570 W60 V28–45 V42.4 / 26.3 V⚠ Works; below MPPT at peak heat0.39
Enphase IQ8M-72-2-US260–460 W60 V30–45 V42.4 / 26.3 V⚠ Works; below MPPT at peak heat0.94
Enphase IQ8A-72-2-US295–500 W60 V32–45 V42.4 / 26.3 V⚠ Works; below MPPT at peak heat0.87
Voltage check against the microinverter datasheets — confirm the pairing on the manufacturer’s module compatibility list. Rows appear only when the panel’s power is inside the microinverter’s recommended module power range.
SolarEdge and other optimizer-based systems size strings by the optimizer rules — use the manufacturer’s designer. Reference inverters: most named in SoCal permits since Oct 2024.

Expected production in Southern California

NLR PVWatts v8 · Cali-Graf calculation
CitykWh / kW / yrkWh / panel / yrkWh / system / yrSun, kWh/m²/day
Los Angeles1,67651111,7576.08
Palmdale1,83556012,8736.69
Chula Vista1,69651711,8976.11
Huntington Beach1,64350111,5265.89
Riverside1,69651711,8976.21
Santa Clarita1,72452612,0946.28
767Jan768Feb986Mar1,089Apr1,075May1,143Jun1,204Jul1,218Aug1,065Sep939Oct807Nov699DeckWh per month · Los Angeles
Estimate for comparison, not a quote: shading, roof orientation and local losses change real output. Roof mount, 20° tilt, south, 14% system losses.

Compare with similar 305 W panels

CEC PV Module List (Oct 7, 2026) · JinkoSolar datasheets · Kiwa PVEL Scorecard · building permits
PanelPmaxEfficiencyγ Pmax (CEC)Voc, VIsc, APVEL (product / brand)SoCal permits (series)
ZNShine Solar ZXM6-60-305/M305 W≈18.5%−0.35639.99.85brand 8×—
JinkoSolar JKM310M-60HBL310 W≈18.4%−0.40740.59.92brand 12× (2014–2026)45
REC Group REC305NP305 W≈18.8%−0.35139.99.93brand 9× (2016–2025)4
Sinotec USA STS-310M3B-60310 W≈18.8%−0.37540.310.04—3
Same fields from the same sources for every row; ≈ efficiency is calculated from the listed area. Comparable series: other brands, same product group, power range covering this class.

Questions & answers

How efficient is the ZNShine Solar ZXM6-60-305/M?

Calculated from the panel area (1.64 m²): about 18.5% for the 305 W class. 305 W over 1.64 m² equals about 186 W per square meter.

How much energy does one panel produce in Los Angeles or Palmdale?

PVWatts v8 with typical-year weather gives about 511 kWh per year per 305 W panel in Los Angeles and about 560 kWh in Palmdale (20° roof, facing south, 14% system losses).

How much power does it lose on a hot roof?

With γ = −0.356 %/°C, at a 77 °C cell temperature (hottest modeled hour in Palmdale) output is about 18.4% below the STC rating.

How many panels fit on one string?

With the Tesla 1538000-xx-y (max DC 600 V, MPPT from 60 V, datasheet) in Los Angeles the calculator gives 3–14 panels per string (Voc at 2 °C = 42.4 V, Vmp at 74 °C cell = 26.3 V). Final design must follow the inverter manual and NEC 690.7.

Has this panel been reliability-tested?

This exact series is not in published PVEL Top Performer tables; ZNShine Solar was named a Top Performer in 8 Scorecards (2016–2026).

Sources

  1. California Energy Commission — Solar Equipment Lists, PV Module List, Inverter List (snapshot Oct 7, 2026).
  2. JinkoSolar — datasheet THE MOST DEPENDABLE SOLAR BRAND.
  3. JinkoSolar — manufacturer datasheet “Eagle HC 60M G2 315-335 Watt MONO PERC HALF CELL MODULE”.
  4. Kiwa PVEL — PV Module Reliability Scorecard, Top Performer lists 2016–2026.
  5. NLR (formerly NREL) — System Advisor Model CEC inverter library (version 2026.7.3).
  6. NLR (formerly NREL) — PVWatts v8, NSRDB PSM v3 typical-year weather for Los Angeles, Palmdale, Chula Vista, Huntington Beach, Riverside, Santa Clarita.
  7. Inverter datasheets — APsystems (Alt Power System), Enphase, Solis (Ginlong), Tesla (manufacturer documents).
  8. Building permits — Southern California permit portals. Equipment matched from permit descriptions.
  9. Cali-Graf calculations — formulas and inputs are shown next to each calculated value (efficiency from area, temperature-corrected voltages, string sizing, energy estimates).