Solar panelZhongshan Ruike New Energy

Zhongshan Ruike New Energy RK-105-2

146 cells. Power classes 75–105 W in the CEC list.

CEC listed · Jun 21, 2021UL 61730
Power class
  • Power (STC)105 WCEC nameplate
  • Efficiency≈14.6%calculated from area
  • %/°C Pmax−0.285CEC listing test
  • PTC / STC94.4%PTC 99 W (CEC)

Power classes

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation · 2 models
ModelPmaxVoc, VIsc, AVmp, VImp, AEfficiencyPTCCEC listed
RK-75-275 W58.502.1042.101.80≈10.4%70 WJun 21, 2021
RK-105-2105 W59.102.6045.802.40≈14.6%99 WJun 21, 2021
≈ efficiency = Pmax ÷ CEC-listed area 0.72 m².

Heat & cold behaviour

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation
CEC listing test
Pmax coefficient γ−0.285 %/°C
Voc coefficient β−0.316 %/°C
Isc coefficient α+0.064 %/°C
Operating cell temperatureNOCT 43.6 °C
Vmp coefficient ≈ γ − α (CEC); used only for the hot-roof voltage estimate.

Away from lab conditions — CEC listing test points

ClassPmax at NOCTVmp × Imp at NOCTPmax at 200 W/m²Low-light efficiency vs STC
75 W62.7 W42.08 V × 1.49 A——
105 W77.8 W41.85 V × 1.86 A19.8 W95%
Pmax = Vmp × Imp from the CEC listing; low-light efficiency = Pmax at 200 W/m² ÷ (20% of STC Pmax).

Inverter compatibility & string sizing

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation · NLR PVWatts v8
63.4 V
Voc when cold
per panel
38 V
Vmp when hot
per panel
Defaults come from NLR TMY weather (coldest hour, hottest modeled cell). Code calculations (NEC 690.7) use the ASHRAE extreme annual minimum, which is usually colder — enter it above. β is the CEC-measured coefficient; NEC 690.7 calculations use the datasheet value.
Microinverter tables are not shown for panels under 200 W.
SolarEdge and other optimizer-based systems size strings by the optimizer rules — use the manufacturer’s designer. Reference inverters: most named in SoCal permits since Oct 2024.

Expected production in Southern California

NLR PVWatts v8 · Cali-Graf calculation
CitykWh / kW / yrkWh / panel / yrkWh / system / yrSun, kWh/m²/day
Los Angeles1,6761765,2796.08
Palmdale1,8351935,7806.69
Chula Vista1,6961785,3426.11
Huntington Beach1,6431735,1755.89
Riverside1,6961785,3426.21
Santa Clarita1,7241815,4316.28
345Jan345Feb443Mar489Apr483May513Jun541Jul547Aug478Sep422Oct363Nov314DeckWh per month · Los Angeles
Estimate for comparison, not a quote: shading, roof orientation and local losses change real output. Roof mount, 20° tilt, south, 14% system losses.

Questions & answers

How efficient is the Zhongshan Ruike New Energy RK-105-2?

Calculated from the panel area (0.72 m²): about 14.6% for the 105 W class. 105 W over 0.72 m² equals about 146 W per square meter.

How much energy does one panel produce in Los Angeles or Palmdale?

PVWatts v8 with typical-year weather gives about 176 kWh per year per 105 W panel in Los Angeles and about 193 kWh in Palmdale (20° roof, facing south, 14% system losses).

How much power does it lose on a hot roof?

With γ = −0.285 %/°C, at a 77 °C cell temperature (hottest modeled hour in Palmdale) output is about 14.8% below the STC rating.