Cali-GrafCali-Graf
Solar panelZhejiang Sunpro Power Technology

Zhejiang Sunpro Power Technology SP540-144M10T

144 half-cut cells. Power classes 520–565 W in the CEC list.

CEC listed · Sep 23, 2024UL 61730
Power class
  • Power (STC)540 WCEC nameplate
  • Efficiency≈21.4%calculated from area
  • %/°C Pmax−0.341CEC listing test
  • PTC / STC93.9%PTC 507 W (CEC)

Power classes

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation · 10 models
ModelPmaxVoc, VIsc, AVmp, VImp, AEfficiencyPTCCEC listed
SP520-144M10T520 W48.9413.5341.0212.68≈20.6%488 WSep 23, 2024
SP525-144M10T525 W49.1113.6141.2112.74≈20.8%493 WSep 23, 2024
SP530-144M10T530 W49.2613.6941.3912.81≈21.0%498 WSep 23, 2024
SP535-144M10T535 W49.4213.7641.5412.88≈21.2%502 WSep 23, 2024
SP540-144M10T540 W49.5813.8441.6912.96≈21.4%507 WSep 23, 2024
SP545-144M10T545 W49.7413.9241.8313.03≈21.6%512 WSep 23, 2024
SP550-144M10T550 W49.9014.0041.9613.11≈21.8%517 WSep 23, 2024
SP555-144M10T555 W50.0614.0842.0913.19≈22.0%522 WSep 23, 2024
SP560-144M10T560 W50.2214.1642.2313.27≈22.2%527 WSep 23, 2024
SP565-144M10T565 W50.3814.2442.3613.34≈22.4%531 WSep 23, 2024
≈ efficiency = Pmax ÷ CEC-listed area 2.52 m².

Build & dimensions

CEC PV Module List (Oct 7, 2026)

Heat & cold behaviour

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation
CEC listing test
Pmax coefficient γ−0.341 %/°C
Voc coefficient β−0.281 %/°C
Isc coefficient α+0.053 %/°C
Operating cell temperatureNOCT 43.9 °C
Vmp coefficient ≈ γ − α (CEC); used only for the hot-roof voltage estimate.

Away from lab conditions — CEC listing test points

ClassPmax at NOCTVmp × Imp at NOCTPmax at 200 W/m²Low-light efficiency vs STC
520 W384.2 W37.79 V × 10.17 A103.9 W100%
525 W387.9 W37.97 V × 10.22 A104.9 W100%
530 W391.7 W38.13 V × 10.27 A105.9 W100%
535 W395.3 W38.27 V × 10.33 A106.9 W100%
540 W399.1 W38.41 V × 10.39 A107.9 W100%
545 W402.6 W38.54 V × 10.45 A108.9 W100%
550 W406.4 W38.66 V × 10.51 A109.9 W100%
555 W410.1 W38.78 V × 10.58 A110.9 W100%
560 W414 W38.91 V × 10.64 A111.9 W100%
565 W417.5 W39.02 V × 10.7 A112.9 W100%
Pmax = Vmp × Imp from the CEC listing; low-light efficiency = Pmax at 200 W/m² ÷ (20% of STC Pmax).

Inverter compatibility & string sizing

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation · NLR PVWatts v8 · inverter datasheets · NLR SAM inverter library · CEC Grid Support Inverter List (Oct 7, 2026)
52.8 V
Voc when cold
per panel
33.6 V
Vmp when hot
per panel
11
Max panels / string
max DC 600 V
2
Min panels / string
MPPT from 60 V
Defaults come from NLR TMY weather (coldest hour, hottest modeled cell). Code calculations (NEC 690.7) use the ASHRAE extreme annual minimum, which is usually colder — enter it above. β is the CEC-measured coefficient; NEC 690.7 calculations use the datasheet value.

String inverters most named in SoCal permits

InverterMax DC inputMPPTWindow sourcePanels per string
Tesla 1538000-xx-y600 V60–480 Vdatasheet2–11
Solis (Ginlong) S6-EH1P10K-H-US600 V80–520 Vdatasheet3–11
Solis (Ginlong) Solis-1P7.6K-4G-US600 V100–500 Vdatasheet3–11
Qcells Q.VOLT H7.6SX498 V234–498 VCEC test window7–9

Microinverters (one per panel)

MicroinverterRecommended module powerMax DC inputMPPTVoc cold / Vmp hotCheckDC/AC
Enphase IQ8X-80-M-US320–540 W79.5 V43–60 V52.8 / 33.6 V✗ Not a match: module voltage below MPPT range1.42
APsystems (Alt Power System) DS3-L265–570 W60 V28–45 V52.8 / 33.6 V✓ Within range0.69
Voltage check against the microinverter datasheets — confirm the pairing on the manufacturer’s module compatibility list. Rows appear only when the panel’s power is inside the microinverter’s recommended module power range.
SolarEdge and other optimizer-based systems size strings by the optimizer rules — use the manufacturer’s designer. Reference inverters: most named in SoCal permits since Oct 2024.

Expected production in Southern California

NLR PVWatts v8 · Cali-Graf calculation
CitykWh / kW / yrkWh / panel / yrkWh / system / yrSun, kWh/m²/day
Los Angeles1,67690511,7666.08
Palmdale1,83599112,8826.69
Chula Vista1,69691611,9066.11
Huntington Beach1,64388711,5345.89
Riverside1,69691611,9066.21
Santa Clarita1,72493112,1026.28
768Jan769Feb986Mar1,090Apr1,076May1,144Jun1,205Jul1,219Aug1,066Sep940Oct808Nov699DeckWh per month · Los Angeles
Estimate for comparison, not a quote: shading, roof orientation and local losses change real output. Roof mount, 20° tilt, south, 14% system losses.

Compare with similar 540 W panels

CEC PV Module List (Oct 7, 2026) · Kiwa PVEL Scorecard · datasheets · building permits
PanelPmaxEfficiencyγ Pmax (CEC)Voc, VIsc, APVEL (product / brand)SoCal permits (series)
Zhejiang Sunpro Power Technology SP540-144M10T540 W≈21.4%−0.34149.5813.84——
JA Solar JAM72D30-540/MB540 W≈21.4%−0.33049.613.86product 2023, 20243
Canadian Solar CS6W-540MB-AG540 W≈21%−0.32449.213.9product 20241
LONGi LR5-72HBD-540M540 W≥21.1%−0.35449.513.85product 20261
Same fields from the same sources for every row; ≈ efficiency is calculated from the listed area. Comparable series: other brands, same product group, power range covering this class.

Questions & answers

How efficient is the Zhejiang Sunpro Power Technology SP540-144M10T?

Calculated from the panel area (2.52 m²): about 21.4% for the 540 W class. 540 W over 2.52 m² equals about 214 W per square meter.

How much energy does one panel produce in Los Angeles or Palmdale?

PVWatts v8 with typical-year weather gives about 905 kWh per year per 540 W panel in Los Angeles and about 991 kWh in Palmdale (20° roof, facing south, 14% system losses).

How much power does it lose on a hot roof?

With γ = −0.341 %/°C, at a 77 °C cell temperature (hottest modeled hour in Palmdale) output is about 17.7% below the STC rating.

How many panels fit on one string?

With the Tesla 1538000-xx-y (max DC 600 V, MPPT from 60 V, datasheet) in Los Angeles the calculator gives 2–11 panels per string (Voc at 2 °C = 52.8 V, Vmp at 74 °C cell = 33.6 V). Final design must follow the inverter manual and NEC 690.7.

Does it work with APsystems (Alt Power System) DS3-L microinverters?

Voltage check against the APsystems (Alt Power System) datasheet: Voc when cold 52.8 V vs max input 60 V; Vmp when hot 33.6 V vs MPPT low 28 V; recommended module power 265–570 W. Confirm on the microinverter maker’s compatibility list.

Sources

  1. California Energy Commission — Solar Equipment Lists, PV Module List, Inverter List (snapshot Oct 7, 2026).
  2. Canadian Solar — datasheet BiHiKu6 BIFACIAL MONO PERC CS6W-520|525|530|535|540|545|550MB-AG.
  3. LONGi — manufacturer datasheet “LR5-72HBD Suitable for distributed projects Advanced module technology delivers superior”.
  4. Kiwa PVEL — PV Module Reliability Scorecard, Top Performer lists.
  5. NLR (formerly NREL) — System Advisor Model CEC inverter library (version 2026.7.3).
  6. NLR (formerly NREL) — PVWatts v8, NSRDB PSM v3 typical-year weather for Los Angeles, Palmdale, Chula Vista, Huntington Beach, Riverside, Santa Clarita.
  7. Inverter datasheets — APsystems (Alt Power System), Enphase, Solis (Ginlong), Tesla (manufacturer documents).
  8. Building permits — Southern California permit portals. Equipment matched from permit descriptions.
  9. Cali-Graf calculations — formulas and inputs are shown next to each calculated value (efficiency from area, temperature-corrected voltages, string sizing, energy estimates).