Solar panelZhejiang Sunpro Power Technology

Zhejiang Sunpro Power Technology SPDG475-N120M10

120 half-cut cells, bifacial, glass (dual-glass module). Power classes 455–500 W in the CEC list.

CEC listed · Sep 11, 2024UL 61730Bifacial
Power class
  • Power (STC)475 WCEC nameplate
  • Efficiency≈22.5%calculated from area
  • %/°C Pmax−0.295CEC listing test
  • PTC / STC95%PTC 451 W (CEC)

Power classes

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation · 10 models
ModelPmaxVoc, VIsc, AVmp, VImp, AEfficiencyPTCCEC listed
SPDG455-N120M10455 W42.1013.8334.7613.09≈21.6%432 WSep 11, 2024
SPDG460-N120M10460 W42.2413.9434.8813.19≈21.8%437 WSep 11, 2024
SPDG465-N120M10465 W42.3814.0334.9913.29≈22.0%442 WSep 11, 2024
SPDG470-N120M10470 W42.5214.1235.1113.39≈22.3%446 WSep 11, 2024
SPDG475-N120M10475 W42.6614.2035.2413.48≈22.5%451 WSep 11, 2024
SPDG480-N120M10480 W42.8014.2935.3813.57≈22.7%456 WSep 11, 2024
SPDG485-N120M10485 W42.9414.3835.5213.66≈23.0%461 WSep 11, 2024
SPDG490-N120M10490 W43.0614.4735.6613.75≈23.2%466 WSep 11, 2024
SPDG495-N120M10495 W43.2114.5635.8013.83≈23.5%471 WMay 1, 2026
SPDG500-N120M10500 W43.3614.6535.9413.92≈23.7%476 WMay 1, 2026
≈ efficiency = Pmax ÷ CEC-listed area 2.11 m².

Build & dimensions

CEC PV Module List (Oct 7, 2026)

Heat & cold behaviour

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation
CEC listing test
Pmax coefficient γ−0.295 %/°C
Voc coefficient β−0.251 %/°C
Isc coefficient α+0.043 %/°C
Operating cell temperatureNOCT 43.4 °C
Vmp coefficient ≈ γ − α (CEC); used only for the hot-roof voltage estimate.

Away from lab conditions — CEC listing test points

ClassPmax at NOCTVmp × Imp at NOCTPmax at 200 W/m²Low-light efficiency vs STC
455 W332.3 W32.46 V × 10.24 A88.4 W97%
460 W336 W32.57 V × 10.32 A89.4 W97%
465 W339.6 W32.68 V × 10.39 A90.3 W97%
470 W343.4 W32.79 V × 10.47 A91.3 W97%
475 W346.9 W32.91 V × 10.54 A92.3 W97%
480 W350.6 W33.04 V × 10.61 A93.3 W97%
485 W354.4 W33.17 V × 10.68 A94.3 W97%
490 W358.1 W33.3 V × 10.75 A95.3 W97%
495 W361.6 W33.43 V × 10.82 A96.2 W97%
500 W365.4 W33.56 V × 10.89 A97.2 W97%
Pmax = Vmp × Imp from the CEC listing; low-light efficiency = Pmax at 200 W/m² ÷ (20% of STC Pmax).

Certifications

CEC PV Module List (Oct 7, 2026) · Clean Energy Council (Australia)
UL 61730IEC 61215:2021 / IEC 61730:2023

Inverter compatibility & string sizing

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation · NLR PVWatts v8 · inverter datasheets · NLR SAM inverter library · CEC Grid Support Inverter List (Oct 7, 2026)
45.1 V
Voc when cold
per panel
29.4 V
Vmp when hot
per panel
13
Max panels / string
max DC 600 V
3
Min panels / string
MPPT from 60 V
Defaults come from NLR TMY weather (coldest hour, hottest modeled cell). Code calculations (NEC 690.7) use the ASHRAE extreme annual minimum, which is usually colder — enter it above. β is the CEC-measured coefficient; NEC 690.7 calculations use the datasheet value.

String inverters most named in SoCal permits

InverterMax DC inputMPPTWindow sourcePanels per string
Tesla 1538000-xx-y600 V60–480 Vdatasheet3–13
Solis (Ginlong) S6-EH1P10K-H-US600 V80–520 Vdatasheet3–13
Solis (Ginlong) Solis-1P7.6K-4G-US600 V100–500 Vdatasheet4–13
Qcells Q.VOLT H7.6SX498 V234–498 VCEC test window8–11

Microinverters (one per panel)

MicroinverterRecommended module powerMax DC inputMPPTVoc cold / Vmp hotCheckDC/AC
Enphase IQ8X-80-M-US320–540 W79.5 V43–60 V45.1 / 29.4 V✗ Not a match: module voltage below MPPT range1.25
APsystems (Alt Power System) DS3-L265–570 W60 V28–45 V45.1 / 29.4 V✓ Within range0.61
Enphase IQ8A-72-2-US295–500 W60 V32–45 V45.1 / 29.4 V⚠ Works; below MPPT at peak heat1.36
Voltage check against the microinverter datasheets — confirm the pairing on the manufacturer’s module compatibility list. Rows appear only when the panel’s power is inside the microinverter’s recommended module power range.
SolarEdge and other optimizer-based systems size strings by the optimizer rules — use the manufacturer’s designer. Reference inverters: most named in SoCal permits since Oct 2024.

Expected production in Southern California

NLR PVWatts v8 · Cali-Graf calculation
CitykWh / kW / yrkWh / panel / yrkWh / system / yrSun, kWh/m²/day
Los Angeles1,67679611,9426.08
Palmdale1,83587213,0746.69
Chula Vista1,69680612,0846.11
Huntington Beach1,64378011,7065.89
Riverside1,69680612,0846.21
Santa Clarita1,72481912,2846.28
779Jan780Feb1,001Mar1,106Apr1,092May1,161Jun1,223Jul1,237Aug1,082Sep954Oct820Nov710DeckWh per month · Los Angeles
Estimate for comparison, not a quote: shading, roof orientation and local losses change real output. Roof mount, 20° tilt, south, 14% system losses.

Compare with similar 475 W panels

CEC PV Module List (Oct 7, 2026) · Kiwa PVEL Scorecard · datasheets · building permits
PanelPmaxEfficiencyγ Pmax (CEC)Voc, VIsc, APVEL (product / brand)SoCal permits (series)
Zhejiang Sunpro Power Technology SPDG475-N120M10475 W≈22.5%−0.29542.6614.2——
REC Group REC475AA Pure-RX475 W≈23.5%−0.24865.79brand 9× (2016–2025)33
SEG Solar SEG-455-BTD-BG455 W≈23.3%−0.26239.7614.11product 2023, 2024, 2025, 20268
Qcells Q.PEAK DUO XL-G10.d 475475 W≥20.5%−0.34053.5811.24product 20236
Same fields from the same sources for every row; ≈ efficiency is calculated from the listed area. Comparable series: other brands, same product group, power range covering this class.

Questions & answers

How efficient is the Zhejiang Sunpro Power Technology SPDG475-N120M10?

Calculated from the panel area (2.11 m²): about 22.5% for the 475 W class. 475 W over 2.11 m² equals about 225 W per square meter.

How much energy does one panel produce in Los Angeles or Palmdale?

PVWatts v8 with typical-year weather gives about 796 kWh per year per 475 W panel in Los Angeles and about 872 kWh in Palmdale (20° roof, facing south, 14% system losses).

How much power does it lose on a hot roof?

With γ = −0.295 %/°C, at a 77 °C cell temperature (hottest modeled hour in Palmdale) output is about 15.3% below the STC rating.

How many panels fit on one string?

With the Tesla 1538000-xx-y (max DC 600 V, MPPT from 60 V, datasheet) in Los Angeles the calculator gives 3–13 panels per string (Voc at 2 °C = 45.1 V, Vmp at 74 °C cell = 29.4 V). Final design must follow the inverter manual and NEC 690.7.

Does it work with APsystems (Alt Power System) DS3-L microinverters?

Voltage check against the APsystems (Alt Power System) datasheet: Voc when cold 45.1 V vs max input 60 V; Vmp when hot 29.4 V vs MPPT low 28 V; recommended module power 265–570 W. Confirm on the microinverter maker’s compatibility list.

Is it bifacial?

Yes. Rear gain depends on mounting height and ground reflectance.

Sources

  1. California Energy Commission — Solar Equipment Lists, PV Module List, Inverter List (snapshot Oct 7, 2026).
  2. SEG Solar — manufacturer datasheet “XXXTFHTPMBSDPN YUKON/Series )BMG$FMM/5ZQF501$PO”.
  3. Qcells — manufacturer datasheet “Q.PEAK DUO XL-G10.d ENDURING HIGH PERFORMANCE”.
  4. Kiwa PVEL — PV Module Reliability Scorecard, Top Performer lists.
  5. NLR (formerly NREL) — System Advisor Model CEC inverter library (version 2026.7.3).
  6. Clean Energy Council (Australia) — Approved PV modules list (as of Oct 8, 2026).
  7. NLR (formerly NREL) — PVWatts v8, NSRDB PSM v3 typical-year weather for Los Angeles, Palmdale, Chula Vista, Huntington Beach, Riverside, Santa Clarita.
  8. Inverter datasheets — APsystems (Alt Power System), Enphase, Solis (Ginlong), Tesla (manufacturer documents).
  9. Building permits — Southern California permit portals. Equipment matched from permit descriptions.
  10. Cali-Graf calculations — formulas and inputs are shown next to each calculated value (efficiency from area, temperature-corrected voltages, string sizing, energy estimates).