Cali-GrafCali-Graf
Solar panelZhejiang Sunpro Power Technology

Zhejiang Sunpro Power Technology SPDG540-144M10

144 half-cut cells. Power classes 520–565 W in the CEC list.

CEC listed · Sep 11, 2024UL 61730
Power class
  • Power (STC)540 WCEC nameplate
  • Efficiency≈21.4%calculated from area
  • %/°C Pmax−0.346CEC listing test
  • PTC / STC94.1%PTC 508 W (CEC)

Power classes

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation · 10 models
ModelPmaxVoc, VIsc, AVmp, VImp, AEfficiencyPTCCEC listed
SPDG520-144M10520 W48.9413.5341.0212.68≈20.6%489 WSep 11, 2024
SPDG525-144M10525 W49.1113.6141.2112.74≈20.8%494 WSep 11, 2024
SPDG530-144M10530 W49.2613.6941.3912.81≈21.0%498 WSep 11, 2024
SPDG535-144M10535 W49.4213.7641.5412.88≈21.2%503 WSep 11, 2024
SPDG540-144M10540 W49.5813.8441.6912.96≈21.4%508 WSep 11, 2024
SPDG545-144M10545 W49.7413.9241.8313.03≈21.6%513 WSep 11, 2024
SPDG550-144M10550 W49.9014.0041.9613.11≈21.8%518 WSep 11, 2024
SPDG555-144M10555 W50.0614.0842.0913.19≈22.0%522 WSep 11, 2024
SPDG560-144M10560 W50.2214.1642.2313.27≈22.2%527 WSep 11, 2024
SPDG565-144M10565 W50.3814.2442.3613.34≈22.4%532 WSep 11, 2024
≈ efficiency = Pmax ÷ CEC-listed area 2.52 m².

Build & dimensions

CEC PV Module List (Oct 7, 2026)

Heat & cold behaviour

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation
CEC listing test
Pmax coefficient γ−0.346 %/°C
Voc coefficient β−0.274 %/°C
Isc coefficient α+0.050 %/°C
Operating cell temperatureNOCT 43.2 °C
Vmp coefficient ≈ γ − α (CEC); used only for the hot-roof voltage estimate.

Away from lab conditions — CEC listing test points

ClassPmax at NOCTVmp × Imp at NOCTPmax at 200 W/m²Low-light efficiency vs STC
520 W383.9 W37.82 V × 10.15 A105.2 W101%
525 W387.5 W38 V × 10.2 A106.2 W101%
530 W391.3 W38.16 V × 10.25 A107.2 W101%
535 W394.9 W38.3 V × 10.31 A108.2 W101%
540 W398.8 W38.44 V × 10.37 A109.3 W101%
545 W402.3 W38.57 V × 10.43 A110.2 W101%
550 W406 W38.69 V × 10.49 A111.3 W101%
555 W409.7 W38.81 V × 10.56 A112.3 W101%
560 W413.6 W38.94 V × 10.62 A113.3 W101%
565 W417 W39.06 V × 10.68 A114.3 W101%
Pmax = Vmp × Imp from the CEC listing; low-light efficiency = Pmax at 200 W/m² ÷ (20% of STC Pmax).

Inverter compatibility & string sizing

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation · NLR PVWatts v8 · inverter datasheets · NLR SAM inverter library · CEC Grid Support Inverter List (Oct 7, 2026)
52.7 V
Voc when cold
per panel
33.6 V
Vmp when hot
per panel
11
Max panels / string
max DC 600 V
2
Min panels / string
MPPT from 60 V
Defaults come from NLR TMY weather (coldest hour, hottest modeled cell). Code calculations (NEC 690.7) use the ASHRAE extreme annual minimum, which is usually colder — enter it above. β is the CEC-measured coefficient; NEC 690.7 calculations use the datasheet value.

String inverters most named in SoCal permits

InverterMax DC inputMPPTWindow sourcePanels per string
Tesla 1538000-xx-y600 V60–480 Vdatasheet2–11
Solis (Ginlong) S6-EH1P10K-H-US600 V80–520 Vdatasheet3–11
Solis (Ginlong) Solis-1P7.6K-4G-US600 V100–500 Vdatasheet3–11
Qcells Q.VOLT H7.6SX498 V234–498 VCEC test window7–9

Microinverters (one per panel)

MicroinverterRecommended module powerMax DC inputMPPTVoc cold / Vmp hotCheckDC/AC
Enphase IQ8X-80-M-US320–540 W79.5 V43–60 V52.7 / 33.6 V✗ Not a match: module voltage below MPPT range1.42
APsystems (Alt Power System) DS3-L265–570 W60 V28–45 V52.7 / 33.6 V✓ Within range0.69
Voltage check against the microinverter datasheets — confirm the pairing on the manufacturer’s module compatibility list. Rows appear only when the panel’s power is inside the microinverter’s recommended module power range.
SolarEdge and other optimizer-based systems size strings by the optimizer rules — use the manufacturer’s designer. Reference inverters: most named in SoCal permits since Oct 2024.

Expected production in Southern California

NLR PVWatts v8 · Cali-Graf calculation
CitykWh / kW / yrkWh / panel / yrkWh / system / yrSun, kWh/m²/day
Los Angeles1,67690511,7666.08
Palmdale1,83599112,8826.69
Chula Vista1,69691611,9066.11
Huntington Beach1,64388711,5345.89
Riverside1,69691611,9066.21
Santa Clarita1,72493112,1026.28
768Jan769Feb986Mar1,090Apr1,076May1,144Jun1,205Jul1,219Aug1,066Sep940Oct808Nov699DeckWh per month · Los Angeles
Estimate for comparison, not a quote: shading, roof orientation and local losses change real output. Roof mount, 20° tilt, south, 14% system losses.

Compare with similar 540 W panels

CEC PV Module List (Oct 7, 2026) · Kiwa PVEL Scorecard · datasheets · building permits
PanelPmaxEfficiencyγ Pmax (CEC)Voc, VIsc, APVEL (product / brand)SoCal permits (series)
Zhejiang Sunpro Power Technology SPDG540-144M10540 W≈21.4%−0.34649.5813.84——
JA Solar JAM72D30-540/MB540 W≈21.4%−0.33049.613.86product 2023, 20243
Canadian Solar CS6W-540MB-AG540 W≈21%−0.32449.213.9product 20241
LONGi LR5-72HBD-540M540 W≥21.1%−0.35449.513.85product 20261
Same fields from the same sources for every row; ≈ efficiency is calculated from the listed area. Comparable series: other brands, same product group, power range covering this class.

Questions & answers

How efficient is the Zhejiang Sunpro Power Technology SPDG540-144M10?

Calculated from the panel area (2.52 m²): about 21.4% for the 540 W class. 540 W over 2.52 m² equals about 214 W per square meter.

How much energy does one panel produce in Los Angeles or Palmdale?

PVWatts v8 with typical-year weather gives about 905 kWh per year per 540 W panel in Los Angeles and about 991 kWh in Palmdale (20° roof, facing south, 14% system losses).

How much power does it lose on a hot roof?

With γ = −0.346 %/°C, at a 77 °C cell temperature (hottest modeled hour in Palmdale) output is about 17.9% below the STC rating.

How many panels fit on one string?

With the Tesla 1538000-xx-y (max DC 600 V, MPPT from 60 V, datasheet) in Los Angeles the calculator gives 2–11 panels per string (Voc at 2 °C = 52.7 V, Vmp at 74 °C cell = 33.6 V). Final design must follow the inverter manual and NEC 690.7.

Does it work with APsystems (Alt Power System) DS3-L microinverters?

Voltage check against the APsystems (Alt Power System) datasheet: Voc when cold 52.7 V vs max input 60 V; Vmp when hot 33.6 V vs MPPT low 28 V; recommended module power 265–570 W. Confirm on the microinverter maker’s compatibility list.

Sources

  1. California Energy Commission — Solar Equipment Lists, PV Module List, Inverter List (snapshot Oct 7, 2026).
  2. Canadian Solar — datasheet BiHiKu6 BIFACIAL MONO PERC CS6W-520|525|530|535|540|545|550MB-AG.
  3. LONGi — manufacturer datasheet “LR5-72HBD Suitable for distributed projects Advanced module technology delivers superior”.
  4. Kiwa PVEL — PV Module Reliability Scorecard, Top Performer lists.
  5. NLR (formerly NREL) — System Advisor Model CEC inverter library (version 2026.7.3).
  6. NLR (formerly NREL) — PVWatts v8, NSRDB PSM v3 typical-year weather for Los Angeles, Palmdale, Chula Vista, Huntington Beach, Riverside, Santa Clarita.
  7. Inverter datasheets — APsystems (Alt Power System), Enphase, Solis (Ginlong), Tesla (manufacturer documents).
  8. Building permits — Southern California permit portals. Equipment matched from permit descriptions.