Cali-GrafCali-Graf
Solar panelWaaree

Waaree Bi-57 530

144 half-cut cells, PERC, bifacial, transparent. Power classes 520–545 W in the CEC list; datasheet covers 520–550 W.

CEC listed · Nov 1, 2022UL 61730Bifacial12-yr product + 27-yr performance warrantyPERC
Power class
  • Power (STC)530 WCEC nameplate
  • Efficiency≥20.6%datasheet minimum
  • %/°C Pmax−0.34CEC test: −0.332
  • Performance warranty27 yrdatasheet

Power classes

CEC PV Module List (Oct 7, 2026) · Waaree datasheet · 6 models
ModelPmaxVoc, VIsc, AVmp, VImp, AEfficiencyPTCCEC listed
Bi-57-520520 W49.0113.5541.1412.65≥20.2%488 WNov 1, 2022
Bi-57-525525 W49.1613.6341.2912.73≥20.4%492 WNov 1, 2022
Bi-57-530530 W49.3113.6941.4512.80≥20.6%497 WNov 1, 2022
Bi-57-535535 W49.4613.7641.6012.88≥20.8%502 WNov 1, 2022
Bi-57-540540 W49.6113.8341.7512.95≥21.0%507 WNov 1, 2022
Bi-57-545545 W49.7613.9041.9013.02≥21.2%512 WNov 1, 2022

Build & dimensions

Waaree datasheet · Cali-Graf calculation · CEC PV Module List (Oct 7, 2026)

Heat & cold behaviour

Waaree datasheet · CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation
DatasheetCEC listing test
Pmax coefficient γ−0.34 %/°C−0.332 %/°C
Voc coefficient β−0.25 %/°C−0.249 %/°C
Isc coefficient α+0.05 %/°C+0.032 %/°C
Vmp coefficient≈ −0.39 %/°C—
Operating cell temperatureNMOT 43 ± 2 °CNOCT 44.6 °C
Vmp coefficient ≈ γ − α (datasheet); used only for the hot-roof voltage estimate.

At normal operating conditions (NOCT, 800 W/m²) — datasheet

ClassPmax, WVoc, VIsc, AVmp, VImp, A
520 W391.946.0010.9437.7010.34
525 W395.646.1011.0037.9010.40
530 W399.246.2011.0538.0010.45
535 W403.146.4011.1138.2010.51
540 W406.746.5011.1638.4010.56
545 W410.446.7011.2238.5010.62

Away from lab conditions — CEC listing test points

ClassPmax at NOCTVmp × Imp at NOCTPmax at 200 W/m²Low-light efficiency vs STC
520 W383.2 W37.54 V × 10.21 A99.6 W96%
525 W387.1 W37.68 V × 10.27 A100.6 W96%
530 W390.7 W37.83 V × 10.33 A101.6 W96%
535 W394.6 W37.96 V × 10.39 A102.6 W96%
540 W398.1 W38.1 V × 10.45 A103.5 W96%
545 W401.7 W38.24 V × 10.51 A104.5 W96%
Pmax = Vmp × Imp from the CEC listing; low-light efficiency = Pmax at 200 W/m² ÷ (20% of STC Pmax).

Electrical & strength ratings

Certifications

CEC PV Module List (Oct 7, 2026) · Waaree datasheet
UL 61730ISO 14001ISO 45001ISO 9001

Warranty & degradation

Waaree datasheet

Independent reliability testing

Kiwa PVEL Scorecard · RETC PV Module Index
5
PVEL Scorecards
Waaree named Top Performer, 2022–2026
2025, 2026
RETC Overall Highest Achiever
Waaree, manufacturer level
This exact series is not listed in published PVEL Top Performer tables. Results below are for the manufacturer.

RETC PV Module Index — Waaree

YearRecognition
2024Test Category High Achiever
2025Overall Highest Achiever
2026Overall Highest Achiever; High achievement in performance; High achievement in reliability; Performance discipline high achiever (Temperature coefficient, Iam, Letid); Quality discipline high achiever (BOM verification); Reliability discipline high achiever (Damp heat, Pid, Tc)

Inverter compatibility & string sizing

Waaree datasheet · Cali-Graf calculation · NLR PVWatts v8 · CEC PV Module List (Oct 7, 2026) · inverter datasheets · NLR SAM inverter library · CEC Grid Support Inverter List (Oct 7, 2026)
52.1 V
Voc when cold
per panel
33.5 V
Vmp when hot
per panel
11
Max panels / string
max DC 600 V
2
Min panels / string
MPPT from 60 V
Defaults come from NLR TMY weather (coldest hour, hottest modeled cell). Code calculations (NEC 690.7) use the ASHRAE extreme annual minimum, which is usually colder — enter it above.

String inverters most named in SoCal permits

InverterMax DC inputMPPTWindow sourcePanels per string
Tesla 1538000-xx-y600 V60–480 Vdatasheet2–11
Solis (Ginlong) S6-EH1P10K-H-US600 V80–520 Vdatasheet3–11
Solis (Ginlong) Solis-1P7.6K-4G-US600 V100–500 Vdatasheet3–11
Qcells Q.VOLT H7.6SX498 V234–498 VCEC test window7–9

Microinverters (one per panel)

MicroinverterRecommended module powerMax DC inputMPPTVoc cold / Vmp hotCheckDC/AC
Enphase IQ8X-80-M-US320–540 W79.5 V43–60 V52.1 / 33.5 V✗ Not a match: module voltage below MPPT range1.39
APsystems (Alt Power System) DS3-L265–570 W60 V28–45 V52.1 / 33.5 V✓ Within range0.68
Voltage check against the microinverter datasheets — confirm the pairing on the manufacturer’s module compatibility list. Rows appear only when the panel’s power is inside the microinverter’s recommended module power range.
SolarEdge and other optimizer-based systems size strings by the optimizer rules — use the manufacturer’s designer. Reference inverters: most named in SoCal permits since Oct 2024.

Expected production in Southern California

NLR PVWatts v8 · Cali-Graf calculation
CitykWh / kW / yrkWh / panel / yrkWh / system / yrSun, kWh/m²/day
Los Angeles1,67688811,5486.08
Palmdale1,83597312,6436.69
Chula Vista1,69689911,6856.11
Huntington Beach1,64387111,3205.89
Riverside1,69689911,6856.21
Santa Clarita1,72491411,8786.28
754Jan754Feb968Mar1,069Apr1,056May1,122Jun1,182Jul1,196Aug1,046Sep923Oct793Nov686DeckWh per month · Los Angeles
Estimate for comparison, not a quote: shading, roof orientation and local losses change real output. Roof mount, 20° tilt, south, 14% system losses.

Compare with similar 530 W panels

CEC PV Module List (Oct 7, 2026) · datasheets · Kiwa PVEL Scorecard · building permits
PanelPmaxEfficiencyγ Pmax (CEC)Voc, VIsc, ASizePVEL (product / brand)SoCal permits (series)
Waaree Bi-57 530530 W≥20.6%−0.33249.3113.6989.4 × 44.6 inbrand 5×—
SEG Solar SEG-525-BTD-BG525 W≈26.9%−0.29041.116.267.8 × 44.6 inproduct 2023, 2024, 2025, 20268
JA Solar JAM72D30-530/MB530 W≈21%−0.33049.313.72—product 2023, 20243
Canadian Solar CS6W-530MB-AG530 W≈20.6%−0.32448.813.889.2 × 44.6 inproduct 20241
Same fields from the same sources for every row; ≈ efficiency is calculated from the listed area. Comparable series: other brands, same product group, power range covering this class.

Documents

manufacturer documents

About Waaree

CEC PV Module List (Oct 7, 2026) · Kiwa PVEL Scorecard · RETC PV Module Index · building permits

Other series by SoCal permits

WSMDi · 3BiN-21BiN-01BiN-02BiN-03BiN-05

Questions & answers

How efficient is the Waaree Bi-57 530?

The Waaree datasheet guarantees at least 20.6% module efficiency for the 530 W class (up to 21.2% for 545 W). 530 W over 2.57 m² equals about 206 W per square meter.

How much energy does one panel produce in Los Angeles or Palmdale?

PVWatts v8 with typical-year weather gives about 888 kWh per year per 530 W panel in Los Angeles and about 973 kWh in Palmdale (20° roof, facing south, 14% system losses).

How much power does it lose on a hot roof?

With γ = −0.34 %/°C, at a 77 °C cell temperature (hottest modeled hour in Palmdale) output is about 17.6% below the STC rating.

How many panels fit on one string?

With the Tesla 1538000-xx-y (max DC 600 V, MPPT from 60 V, datasheet) in Los Angeles the calculator gives 2–11 panels per string (Voc at 2 °C = 52.1 V, Vmp at 74 °C cell = 33.5 V). Final design must follow the inverter manual and NEC 690.7.

Does it work with APsystems (Alt Power System) DS3-L microinverters?

Voltage check against the APsystems (Alt Power System) datasheet: Voc when cold 52.1 V vs max input 60 V; Vmp when hot 33.5 V vs MPPT low 28 V; recommended module power 265–570 W. Confirm on the microinverter maker’s compatibility list.

What does the warranty cover?

12 years on the product and 27 years on performance (manufacturer datasheet).

How big and heavy is it?

89.4 × 44.6 × 1.38 in (2,272 × 1,133 × 35 mm), 60.6 lb (27.5 kg).

Is it bifacial?

Yes. Rear gain depends on mounting height and ground reflectance.

Sources

  1. California Energy Commission — Solar Equipment Lists, PV Module List, Inverter List (snapshot Oct 7, 2026).
  2. Waaree — datasheet AHNAY SERIES Bi-57-520-550 WEL-E&PD-520-550-144-MPB-HC-10.
  3. SEG Solar — manufacturer datasheet “XXXTFHTPMBSDPN YUKON/Series )BMG$FMM/5ZQF501$PO”.
  4. Canadian Solar — datasheet BiHiKu6 BIFACIAL MONO PERC CS6W-520|525|530|535|540|545|550MB-AG.
  5. Waaree — document library on the manufacturer’s website (links above).
  6. Kiwa PVEL — PV Module Reliability Scorecard, Top Performer lists 2022–2026.
  7. RETC — PV Module Index reports 2024–2026.
  8. NLR (formerly NREL) — System Advisor Model CEC module and inverter libraries (version 2026.7.3).
  9. NLR (formerly NREL) — PVWatts v8, NSRDB PSM v3 typical-year weather for Los Angeles, Palmdale, Chula Vista, Huntington Beach, Riverside, Santa Clarita.
  10. Inverter datasheets — APsystems (Alt Power System), Enphase, Solis (Ginlong), Tesla (manufacturer documents).
  11. Building permits — Southern California permit portals. Equipment matched from permit descriptions.
  12. Cali-Graf calculations — formulas and inputs are shown next to each calculated value (efficiency from area, temperature-corrected voltages, string sizing, energy estimates).