Cali-GrafCali-Graf
Solar panelVSUN (Vietnam Sunergy)

VSUN (Vietnam Sunergy) VSUN680N-132BMH-DG

132 half-cut cells, bifacial, glass (dual-glass module). Power classes 520–710 W in the CEC list.

CEC listed · Apr 11, 2025UL 61730BifacialPVEL Top Performer 2024
Power class
  • Power (STC)680 WCEC nameplate
  • Efficiency≈21.9%calculated from area
  • %/°C Pmax−0.304CEC listing test
  • PTC / STC94.3%PTC 641 W (CEC)

Power classes

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation · 13 models
ModelPmaxVoc, VIsc, AVmp, VImp, AEfficiencyPTCCEC listed
VSUN520N-132BMH-DG520 W47.1913.6839.8813.04≈21.9%492 WJul 1, 2025
VSUN525N-132BMH-DG525 W47.4113.7440.1113.09≈22.1%497 WJul 1, 2025
VSUN530N-132BMH-DG530 W47.6313.8040.3413.14≈22.3%502 WJul 1, 2025
VSUN535N-132BMH-DG535 W47.8513.8640.5713.19≈22.5%507 WJul 1, 2025
VSUN540N-132BMH-DG540 W48.0913.9140.7913.24≈22.7%512 WJul 1, 2025
VSUN545N-132BMH-DG545 W48.3013.9741.0113.29≈23.0%517 WJul 1, 2025
VSUN680N-132BMH-DG680 W47.4018.1839.6017.16≈21.9%641 WApr 11, 2025
VSUN685N-132BMH-DG685 W47.7018.2139.8017.19≈22.1%646 WApr 11, 2025
VSUN690N-132BMH-DG690 W47.9018.2540.1017.23≈22.2%651 WApr 11, 2025
VSUN695N-132BMH-DG695 W48.3018.2840.3017.25≈22.4%656 WApr 11, 2025
VSUN700N-132BMH-DG700 W48.5018.3240.5017.29≈22.5%661 WApr 11, 2025
VSUN705N-132BMH-DG705 W48.7018.3740.7017.33≈22.7%666 WApr 11, 2025
VSUN710N-132BMH-DG710 W48.9018.4240.9017.36≈22.9%670 WApr 11, 2025
≈ efficiency = Pmax ÷ CEC-listed area 2.37 m².

Build & dimensions

CEC PV Module List (Oct 7, 2026)

Heat & cold behaviour

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation
CEC listing test
Pmax coefficient γ−0.304 %/°C
Voc coefficient β−0.236 %/°C
Isc coefficient α+0.035 %/°C
Operating cell temperatureNOCT 45.1 °C
Vmp coefficient ≈ γ − α (CEC); used only for the hot-roof voltage estimate.

Away from lab conditions — CEC listing test points

ClassPmax at NOCTVmp × Imp at NOCTPmax at 200 W/m²Low-light efficiency vs STC
520 W394 W38.48 V × 10.24 A100.6 W97%
525 W397.7 W38.7 V × 10.28 A101.6 W97%
530 W401.6 W38.92 V × 10.32 A102.6 W97%
535 W405.4 W39.15 V × 10.36 A103.5 W97%
540 W409.1 W39.36 V × 10.4 A104.5 W97%
545 W412.9 W39.57 V × 10.43 A105.5 W97%
680 W504.7 W37.87 V × 13.33 A130.4 W96%
685 W508.1 W38.06 V × 13.35 A131.3 W96%
690 W513.1 W38.35 V × 13.38 A132.6 W96%
695 W516.3 W38.54 V × 13.4 A133.4 W96%
700 W520 W38.73 V × 13.43 A134.4 W96%
705 W523.8 W38.92 V × 13.46 A135.4 W96%
710 W527.3 W39.12 V × 13.48 A136.3 W96%
Pmax = Vmp × Imp from the CEC listing; low-light efficiency = Pmax at 200 W/m² ÷ (20% of STC Pmax).

Independent reliability testing

Kiwa PVEL Scorecard · RETC PV Module Index
2024
PVEL Top Performer
this series
3
Tests passed as Top Performer
DH, LID+LETID, PID
6
PVEL Scorecards
VSUN (Vietnam Sunergy) named Top Performer, 2021–2026
2025, 2026
RETC Overall Highest Achiever
VSUN (Vietnam Sunergy), manufacturer level

PVEL Top Performer tests

YearProductTests
2024VSUNxxxN-132BMH-DGDHLID+LETIDPID
2024VSUNxxxN-132BMH (closely related product name)LID+LETID

Tested bill of materials

Details describe the tested sample, not every module of the series.

RETC PV Module Index — VSUN (Vietnam Sunergy)

YearRecognition
2024Test Category High Achiever
2025Overall Highest Achiever
2026Overall Highest Achiever; High achievement in performance; High achievement in reliability; Performance discipline high achiever (Lid, PAN file, Temperature coefficient, Iam, Letid); Quality discipline high achiever (BOM verification); Reliability discipline high achiever (Damp heat, Pid, Sdml, Tc, Uvid)

Inverter compatibility & string sizing

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation · NLR PVWatts v8 · inverter datasheets · NLR SAM inverter library · CEC Grid Support Inverter List (Oct 7, 2026)
50 V
Voc when cold
per panel
33 V
Vmp when hot
per panel
12
Max panels / string
max DC 600 V
2
Min panels / string
MPPT from 60 V
Defaults come from NLR TMY weather (coldest hour, hottest modeled cell). Code calculations (NEC 690.7) use the ASHRAE extreme annual minimum, which is usually colder — enter it above. β is the CEC-measured coefficient; NEC 690.7 calculations use the datasheet value.

String inverters most named in SoCal permits

InverterMax DC inputMPPTWindow sourcePanels per string
Tesla 1538000-xx-y600 V60–480 Vdatasheet2–12
Solis (Ginlong) S6-EH1P10K-H-US600 V80–520 Vdatasheet3–12
Solis (Ginlong) Solis-1P7.6K-4G-US600 V100–500 Vdatasheet4–12
Qcells Q.VOLT H7.6SX498 V234–498 VCEC test window8–9

Microinverters (one per panel)

No microinverter in the reference set lists this power class in its recommended module power range.
Voltage check against the microinverter datasheets — confirm the pairing on the manufacturer’s module compatibility list. Rows appear only when the panel’s power is inside the microinverter’s recommended module power range.
SolarEdge and other optimizer-based systems size strings by the optimizer rules — use the manufacturer’s designer. Reference inverters: most named in SoCal permits since Oct 2024.

Expected production in Southern California

NLR PVWatts v8 · Cali-Graf calculation
CitykWh / kW / yrkWh / panel / yrkWh / system / yrSun, kWh/m²/day
Los Angeles1,6761,14011,3976.08
Palmdale1,8351,24812,4786.69
Chula Vista1,6961,15311,5336.11
Huntington Beach1,6431,11711,1725.89
Riverside1,6961,15311,5336.21
Santa Clarita1,7241,17211,7236.28
744Jan745Feb955Mar1,055Apr1,042May1,108Jun1,167Jul1,180Aug1,032Sep911Oct783Nov677DeckWh per month · Los Angeles
Estimate for comparison, not a quote: shading, roof orientation and local losses change real output. Roof mount, 20° tilt, south, 14% system losses.

Compare with similar 680 W panels

CEC PV Module List (Oct 7, 2026) · datasheets · Kiwa PVEL Scorecard
PanelPmaxEfficiencyγ Pmax (CEC)Voc, VIsc, APVEL (product / brand)
VSUN (Vietnam Sunergy) VSUN680N-132BMH-DG680 W≈21.9%−0.30447.418.18product 2024
Canadian Solar CS7N-680TB-AG680 W≈21.9%−0.28547.118.29product 2024
Waaree BiN-03-680680 W≥21.9%−0.30247.5518.16brand 5× (2022–2026)
Same fields from the same sources for every row; ≈ efficiency is calculated from the listed area. Comparable series: other brands, same product group, power range covering this class.

About VSUN (Vietnam Sunergy)

CEC PV Module List (Oct 7, 2026) · Kiwa PVEL Scorecard · RETC PV Module Index · building permits

Other series by SoCal permits

VSUNxxxN-108BMH-BB · 4VSUNxxxN-108MH-BB · 3VSUNxxxN-144MH · 1VSUNxxx-108BMH · 1VSUNxxx-108M-BB · 1VSUNxxxN-108BMH

Questions & answers

How efficient is the VSUN (Vietnam Sunergy) VSUN680N-132BMH-DG?

Calculated from the panel area (3.11 m²): about 21.9% for the 680 W class. 680 W over 3.11 m² equals about 219 W per square meter.

How much energy does one panel produce in Los Angeles or Palmdale?

PVWatts v8 with typical-year weather gives about 1,140 kWh per year per 680 W panel in Los Angeles and about 1,248 kWh in Palmdale (20° roof, facing south, 14% system losses).

How much power does it lose on a hot roof?

With γ = −0.304 %/°C, at a 77 °C cell temperature (hottest modeled hour in Palmdale) output is about 15.7% below the STC rating.

How many panels fit on one string?

With the Tesla 1538000-xx-y (max DC 600 V, MPPT from 60 V, datasheet) in Los Angeles the calculator gives 2–12 panels per string (Voc at 2 °C = 50 V, Vmp at 74 °C cell = 33 V). Final design must follow the inverter manual and NEC 690.7.

Is it bifacial?

Yes. Rear gain depends on mounting height and ground reflectance.

Has this panel been reliability-tested?

VSUNxxxN-132BMH-DG was a PVEL Top Performer in 2024 (DH, LID+LETID, PID).

Sources

  1. California Energy Commission — Solar Equipment Lists, PV Module List, Inverter List (snapshot Oct 7, 2026).
  2. Canadian Solar — datasheet New N-type Bifacial Module TOPBiHiKu7 CS7N-725|730|735|740|745|750TB-AG.
  3. Waaree — datasheet ELITE SERIES BiN-03.
  4. Kiwa PVEL — PV Module Reliability Scorecard, Top Performer lists 2021–2026.
  5. RETC — PV Module Index reports 2024–2026.
  6. NLR (formerly NREL) — System Advisor Model CEC module and inverter libraries (version 2026.7.3).
  7. NLR (formerly NREL) — PVWatts v8, NSRDB PSM v3 typical-year weather for Los Angeles, Palmdale, Chula Vista, Huntington Beach, Riverside, Santa Clarita.
  8. Inverter datasheets — Solis (Ginlong), Tesla (manufacturer documents).
  9. Building permits — Southern California permit portals. Equipment matched from permit descriptions.
  10. Cali-Graf calculations — formulas and inputs are shown next to each calculated value (efficiency from area, temperature-corrected voltages, string sizing, energy estimates).