VSUN (Vietnam Sunergy) VSUN475N-120MH

120 cells. Power classes 460–490 W in the CEC list.

CEC listed · Aug 21, 2024UL 61730
Power class
  • Power (STC)475 WCEC nameplate
  • Efficiency≈22.0%calculated from area
  • %/°C Pmax−0.345CEC listing test
  • PTC / STC93.3%PTC 443 W (CEC)

Power classes

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation · 7 models
ModelPmaxVoc, VIsc, AVmp, VImp, AEfficiencyPTCCEC listed
VSUN460N-120MH460 W41.9713.6335.5512.94≈21.3%429 WAug 21, 2024
VSUN465N-120MH465 W42.2513.6835.8112.99≈21.5%434 WAug 21, 2024
VSUN470N-120MH470 W42.5113.7336.0213.05≈21.8%439 WAug 21, 2024
VSUN475N-120MH475 W42.7813.7836.2413.11≈22.0%443 WAug 21, 2024
VSUN480N-120MH480 W43.0513.8336.4913.16≈22.2%448 WAug 21, 2024
VSUN485N-120MH485 W43.3013.8836.7213.21≈22.5%453 WAug 21, 2024
VSUN490N-120MH490 W43.5413.9436.9413.27≈22.7%458 WAug 21, 2024
≈ efficiency = Pmax ÷ CEC-listed area 2.16 m².

Build & dimensions

CEC PV Module List (Oct 7, 2026)

Heat & cold behaviour

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation
CEC listing test
Pmax coefficient γ−0.345 %/°C
Voc coefficient β−0.277 %/°C
Isc coefficient α+0.040 %/°C
Operating cell temperatureNOCT 45.8 °C
Vmp coefficient ≈ γ − α (CEC); used only for the hot-roof voltage estimate.

Away from lab conditions — CEC listing test points

ClassPmax at NOCTVmp × Imp at NOCTPmax at 200 W/m²Low-light efficiency vs STC
460 W344.7 W32.35 V × 10.66 A89.6 W97%
465 W348.6 W32.58 V × 10.7 A90.6 W97%
470 W352.3 W32.77 V × 10.75 A91.6 W97%
475 W356 W32.97 V × 10.8 A92.6 W97%
480 W359.9 W33.2 V × 10.84 A93.6 W97%
485 W363.5 W33.41 V × 10.88 A94.5 W97%
490 W367.3 W33.61 V × 10.93 A95.5 W97%
Pmax = Vmp × Imp from the CEC listing; low-light efficiency = Pmax at 200 W/m² ÷ (20% of STC Pmax).

Independent reliability testing

Kiwa PVEL Scorecard · RETC PV Module Index
2024
PVEL Top Performer
closely related product name
1
Tests passed as Top Performer
LID+LETID
6
PVEL Scorecards
VSUN (Vietnam Sunergy) named Top Performer, 2021–2026
2025, 2026
RETC Overall Highest Achiever
VSUN (Vietnam Sunergy), manufacturer level

PVEL Top Performer tests

YearProductTests
2024VSUNxxxN-120MH-BB (closely related product name)LID+LETID

Tested bill of materials

Details describe the tested sample, not every module of the series.

RETC PV Module Index — VSUN (Vietnam Sunergy)

YearRecognition
2024Test Category High Achiever
2025Overall Highest Achiever
2026Overall Highest Achiever; High achievement in performance; High achievement in reliability; Performance discipline high achiever (Lid, PAN file, Temperature coefficient, Iam, Letid); Quality discipline high achiever (BOM verification); Reliability discipline high achiever (Damp heat, Pid, Sdml, Tc, Uvid)

Inverter compatibility & string sizing

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation · NLR PVWatts v8 · inverter datasheets · NLR SAM inverter library · CEC Grid Support Inverter List (Oct 7, 2026)
45.5 V
Voc when cold
per panel
29.4 V
Vmp when hot
per panel
13
Max panels / string
max DC 600 V
3
Min panels / string
MPPT from 60 V
Defaults come from NLR TMY weather (coldest hour, hottest modeled cell). Code calculations (NEC 690.7) use the ASHRAE extreme annual minimum, which is usually colder — enter it above. β is the CEC-measured coefficient; NEC 690.7 calculations use the datasheet value.

String inverters most named in SoCal permits

InverterMax DC inputMPPTWindow sourcePanels per string
Tesla 1538000-xx-y600 V60–480 Vdatasheet3–13
Solis (Ginlong) S6-EH1P10K-H-US600 V80–520 Vdatasheet3–13
Solis (Ginlong) Solis-1P7.6K-4G-US600 V100–500 Vdatasheet4–13
Qcells Q.VOLT H7.6SX498 V234–498 VCEC test window8–10

Microinverters (one per panel)

MicroinverterRecommended module powerMax DC inputMPPTVoc cold / Vmp hotCheckDC/AC
Enphase IQ8X-80-M-US320–540 W79.5 V43–60 V45.5 / 29.4 V✗ Not a match: module voltage below MPPT range1.25
APsystems (Alt Power System) DS3-L265–570 W60 V28–45 V45.5 / 29.4 V✓ Within range0.61
Enphase IQ8A-72-2-US295–500 W60 V32–45 V45.5 / 29.4 V⚠ Works; below MPPT at peak heat1.36
Voltage check against the microinverter datasheets — confirm the pairing on the manufacturer’s module compatibility list. Rows appear only when the panel’s power is inside the microinverter’s recommended module power range.
SolarEdge and other optimizer-based systems size strings by the optimizer rules — use the manufacturer’s designer. Reference inverters: most named in SoCal permits since Oct 2024.

Expected production in Southern California

NLR PVWatts v8 · Cali-Graf calculation
CitykWh / kW / yrkWh / panel / yrkWh / system / yrSun, kWh/m²/day
Los Angeles1,67679611,9426.08
Palmdale1,83587213,0746.69
Chula Vista1,69680612,0846.11
Huntington Beach1,64378011,7065.89
Riverside1,69680612,0846.21
Santa Clarita1,72481912,2846.28
779Jan780Feb1,001Mar1,106Apr1,092May1,161Jun1,223Jul1,237Aug1,082Sep954Oct820Nov710DeckWh per month · Los Angeles
Estimate for comparison, not a quote: shading, roof orientation and local losses change real output. Roof mount, 20° tilt, south, 14% system losses.

Compare with similar 475 W panels

CEC PV Module List (Oct 7, 2026) · Kiwa PVEL Scorecard · datasheets · building permits
PanelPmaxEfficiencyγ Pmax (CEC)Voc, VIsc, APVEL (product / brand)SoCal permits (series)
VSUN (Vietnam Sunergy) VSUN475N-120MH475 W≈22%−0.34542.7813.78brand 6×—
REC Group REC475AA Pure-RX475 W≈23.5%−0.24865.79brand 9× (2016–2025)33
SEG Solar SEG-455-BTD-BG455 W≈23.3%−0.26239.7614.11product 2023, 2024, 2025, 20268
Qcells Q.PEAK DUO XL-G10.d 475475 W≥20.5%−0.34053.5811.24product 20236
Same fields from the same sources for every row; ≈ efficiency is calculated from the listed area. Comparable series: other brands, same product group, power range covering this class.

About VSUN (Vietnam Sunergy)

CEC PV Module List (Oct 7, 2026) · Kiwa PVEL Scorecard · RETC PV Module Index · building permits

Other series by SoCal permits

VSUNxxxN-108BMH-BB · 4VSUNxxxN-108MH-BB · 3VSUNxxxN-144MH · 1VSUNxxx-108BMH · 1VSUNxxx-108M-BB · 1VSUNxxxN-108BMH

Questions & answers

How efficient is the VSUN (Vietnam Sunergy) VSUN475N-120MH?

Calculated from the panel area (2.16 m²): about 22% for the 475 W class. 475 W over 2.16 m² equals about 220 W per square meter.

How much energy does one panel produce in Los Angeles or Palmdale?

PVWatts v8 with typical-year weather gives about 796 kWh per year per 475 W panel in Los Angeles and about 872 kWh in Palmdale (20° roof, facing south, 14% system losses).

How much power does it lose on a hot roof?

With γ = −0.345 %/°C, at a 77 °C cell temperature (hottest modeled hour in Palmdale) output is about 17.8% below the STC rating.

How many panels fit on one string?

With the Tesla 1538000-xx-y (max DC 600 V, MPPT from 60 V, datasheet) in Los Angeles the calculator gives 3–13 panels per string (Voc at 2 °C = 45.5 V, Vmp at 74 °C cell = 29.4 V). Final design must follow the inverter manual and NEC 690.7.

Does it work with APsystems (Alt Power System) DS3-L microinverters?

Voltage check against the APsystems (Alt Power System) datasheet: Voc when cold 45.5 V vs max input 60 V; Vmp when hot 29.4 V vs MPPT low 28 V; recommended module power 265–570 W. Confirm on the microinverter maker’s compatibility list.

Has this panel been reliability-tested?

VSUNxxxN-120MH-BB was a PVEL Top Performer in 2024 (LID+LETID) — a closely related product name.

Sources

  1. California Energy Commission — Solar Equipment Lists, PV Module List, Inverter List (snapshot Oct 7, 2026).
  2. SEG Solar — manufacturer datasheet “XXXTFHTPMBSDPN YUKON/Series )BMG$FMM/5ZQF501$PO”.
  3. Qcells — manufacturer datasheet “Q.PEAK DUO XL-G10.d ENDURING HIGH PERFORMANCE”.
  4. Kiwa PVEL — PV Module Reliability Scorecard, Top Performer lists 2021–2026.
  5. RETC — PV Module Index reports 2024–2026.
  6. NLR (formerly NREL) — System Advisor Model CEC inverter library (version 2026.7.3).
  7. NLR (formerly NREL) — PVWatts v8, NSRDB PSM v3 typical-year weather for Los Angeles, Palmdale, Chula Vista, Huntington Beach, Riverside, Santa Clarita.
  8. Inverter datasheets — APsystems (Alt Power System), Enphase, Solis (Ginlong), Tesla (manufacturer documents).
  9. Building permits — Southern California permit portals. Equipment matched from permit descriptions.
  10. Cali-Graf calculations — formulas and inputs are shown next to each calculated value (efficiency from area, temperature-corrected voltages, string sizing, energy estimates).