156 half-cut cells, bifacial. Power classes 465–495 W in the CEC list.
| Model | Pmax | Voc, V | Isc, A | Vmp, V | Imp, A | Efficiency | PTC | CEC listed |
|---|---|---|---|---|---|---|---|---|
| VSUN465-156BMH | 465 W | 52.50 | 11.22 | 43.70 | 10.64 | ≈19.5% | 432 W | Jan 3, 2022 |
| VSUN470-156BMH | 470 W | 52.70 | 11.29 | 43.90 | 10.71 | ≈19.7% | 436 W | Jan 3, 2022 |
| VSUN475-156BMH | 475 W | 52.90 | 11.35 | 44.10 | 10.77 | ≈19.9% | 441 W | Jan 3, 2022 |
| VSUN480-156BMH | 480 W | 53.10 | 11.42 | 44.30 | 10.84 | ≈20.1% | 446 W | Jan 3, 2022 |
| VSUN485-156BMH | 485 W | 53.30 | 11.48 | 44.50 | 10.90 | ≈20.3% | 451 W | Jan 3, 2022 |
| VSUN490-156BMH | 490 W | 53.50 | 11.55 | 44.70 | 10.97 | ≈20.5% | 456 W | Jan 3, 2022 |
| VSUN495-156BMH | 495 W | 53.70 | 11.62 | 44.90 | 11.03 | ≈20.7% | 460 W | Jan 3, 2022 |
| CEC listing test | |
|---|---|
| Pmax coefficient γ | −0.347 %/°C |
| Voc coefficient β | −0.284 %/°C |
| Isc coefficient α | +0.057 %/°C |
| Operating cell temperature | NOCT 46.2 °C |
| Class | Pmax at NOCT | Vmp × Imp at NOCT | Pmax at 200 W/m² | Low-light efficiency vs STC |
|---|---|---|---|---|
| 465 W | 352.5 W | 41.64 V × 8.46 A | 93.7 W | 101% |
| 470 W | 356.4 W | 41.83 V × 8.52 A | 94.7 W | 101% |
| 475 W | 360.1 W | 42.02 V × 8.57 A | 95.7 W | 101% |
| 480 W | 364.1 W | 42.22 V × 8.62 A | 96.7 W | 101% |
| 485 W | 367.7 W | 42.41 V × 8.67 A | 97.7 W | 101% |
| 490 W | 371.7 W | 42.6 V × 8.73 A | 98.8 W | 101% |
| 495 W | 375.5 W | 42.79 V × 8.77 A | 99.7 W | 101% |
| Year | Recognition |
|---|---|
| 2024 | Test Category High Achiever |
| 2025 | Overall Highest Achiever |
| 2026 | Overall Highest Achiever; High achievement in performance; High achievement in reliability; Performance discipline high achiever (Lid, PAN file, Temperature coefficient, Iam, Letid); Quality discipline high achiever (BOM verification); Reliability discipline high achiever (Damp heat, Pid, Sdml, Tc, Uvid) |
| Inverter | Max DC input | MPPT | Window source | Panels per string |
|---|---|---|---|---|
| Tesla 1538000-xx-y | 600 V | 60–480 V | datasheet | 2–10 |
| Solis (Ginlong) S6-EH1P10K-H-US | 600 V | 80–520 V | datasheet | 3–10 |
| Solis (Ginlong) Solis-1P7.6K-4G-US | 600 V | 100–500 V | datasheet | 3–10 |
| Qcells Q.VOLT H7.6SX | 498 V | 234–498 V | CEC test window | 7–8 |
| Microinverter | Recommended module power | Max DC input | MPPT | Voc cold / Vmp hot | Check | DC/AC |
|---|---|---|---|---|---|---|
| Enphase IQ8X-80-M-US | 320–540 W | 79.5 V | 43–60 V | 56.6 / 35.5 V | ⚠ Works; below MPPT at peak heat | 1.26 |
| APsystems (Alt Power System) DS3-L | 265–570 W | 60 V | 28–45 V | 56.6 / 35.5 V | ✓ Within range | 0.62 |
| Enphase IQ8A-72-2-US | 295–500 W | 60 V | 32–45 V | 56.6 / 35.5 V | ✓ Within range | 1.38 |
| City | kWh / kW / yr | kWh / panel / yr | kWh / system / yr | Sun, kWh/m²/day |
|---|---|---|---|---|
| Los Angeles | 1,676 | 804 | 12,067 | 6.08 |
| Palmdale | 1,835 | 881 | 13,212 | 6.69 |
| Chula Vista | 1,696 | 814 | 12,211 | 6.11 |
| Huntington Beach | 1,643 | 789 | 11,830 | 5.89 |
| Riverside | 1,696 | 814 | 12,211 | 6.21 |
| Santa Clarita | 1,724 | 828 | 12,413 | 6.28 |
| Panel | Pmax | Efficiency | γ Pmax (CEC) | Voc, V | Isc, A | PVEL (product / brand) | SoCal permits (series) |
|---|---|---|---|---|---|---|---|
| VSUN (Vietnam Sunergy) VSUN480-156BMH | 480 W | ≈20.1% | −0.347 | 53.1 | 11.42 | brand 6× | — |
| REC Group REC475AA Pure-RX | 475 W | ≈23.5% | −0.248 | 65.7 | 9 | brand 9× (2016–2025) | 33 |
| SEG Solar SEG-495-BTD-BG | 495 W | ≈25.3% | −0.290 | 39.9 | 15.82 | product 2023, 2024, 2025, 2026 | 8 |
| Qcells Q.PEAK DUO XL-G10.d 480 | 480 W | ≥20.7% | −0.340 | 53.61 | 11.26 | product 2023 | 6 |
Calculated from the panel area (2.39 m²): about 20.1% for the 480 W class. 480 W over 2.39 m² equals about 201 W per square meter.
PVWatts v8 with typical-year weather gives about 804 kWh per year per 480 W panel in Los Angeles and about 881 kWh in Palmdale (20° roof, facing south, 14% system losses).
With γ = −0.347 %/°C, at a 77 °C cell temperature (hottest modeled hour in Palmdale) output is about 18% below the STC rating.
With the Tesla 1538000-xx-y (max DC 600 V, MPPT from 60 V, datasheet) in Los Angeles the calculator gives 2–10 panels per string (Voc at 2 °C = 56.6 V, Vmp at 74 °C cell = 35.5 V). Final design must follow the inverter manual and NEC 690.7.
Voltage check against the APsystems (Alt Power System) datasheet: Voc when cold 56.6 V vs max input 60 V; Vmp when hot 35.5 V vs MPPT low 28 V; recommended module power 265–570 W. Confirm on the microinverter maker’s compatibility list.
Yes. Rear gain depends on mounting height and ground reflectance.
This exact series is not in published PVEL Top Performer tables; VSUN (Vietnam Sunergy) was named a Top Performer in 6 Scorecards (2021–2026). RETC named VSUN (Vietnam Sunergy) Overall Highest Achiever in 2025, 2026.