Cali-GrafCali-Graf
Solar panelVSUN (Vietnam Sunergy)

VSUN (Vietnam Sunergy) VSUN450-144BMH-DG

144 half-cut cells, bifacial, glass (dual-glass module). Power classes 380–560 W in the CEC list.

CEC listed · Nov 2, 2020UL 61730BifacialPVEL Top Performer 2023, 2024
Power class
  • Power (STC)450 WCEC nameplate
  • Efficiency≈20.4%calculated from area
  • %/°C Pmax−0.331CEC listing test
  • PTC / STC93.3%PTC 420 W (CEC)

Power classes

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation · 23 models
ModelPmaxVoc, VIsc, AVmp, VImp, AEfficiencyPTCCEC listed
VSUN380-144BMH-DG380 W48.709.9440.209.47≈18.8%352 WNov 2, 2020
VSUN385-144BMH-DG385 W48.9010.0240.409.54≈19.1%356 WNov 2, 2020
VSUN390-144BMH-DG390 W49.1010.1140.609.61≈19.3%361 WNov 2, 2020
VSUN395-144BMH-DG395 W49.3010.1940.809.69≈19.6%366 WNov 2, 2020
VSUN400-144BMH-DG400 W49.5010.2741.009.76≈19.8%371 WNov 2, 2020
VSUN405-144BMH-DG405 W49.7010.3641.209.84≈20.0%376 WNov 2, 2020
VSUN410-144BMH-DG410 W49.9010.4441.409.91≈20.3%380 WNov 2, 2020
VSUN430-144BMH-DG430 W48.6011.2040.4010.65≈19.5%401 WApr 1, 2021
VSUN435-144BMH-DG435 W48.8011.2840.6010.72≈19.7%405 WApr 1, 2021
VSUN440-144BMH-DG440 W49.0011.3640.8010.79≈20.0%410 WApr 1, 2021
VSUN445-144BMH-DG445 W49.2011.4441.0010.86≈20.2%415 WApr 1, 2021
VSUN450-144BMH-DG450 W49.4011.5241.2010.93≈20.4%420 WApr 1, 2021
VSUN455-144BMH-DG455 W49.6011.6041.4011.00≈20.6%425 WApr 1, 2021
VSUN460-144BMH-DG460 W49.8011.6741.6011.06≈20.9%429 WApr 1, 2021
VSUN520-144BMH-DG520 W49.1113.5341.1112.65≈20.2%485 WDec 13, 2021
VSUN525-144BMH-DG525 W49.2213.6341.2212.74≈20.3%490 WDec 13, 2021
VSUN530-144BMH-DG530 W49.3513.7141.3512.82≈20.5%495 WDec 13, 2021
VSUN535-144BMH-DG535 W49.5013.7841.5012.90≈20.7%500 WDec 13, 2021
VSUN540-144BMH-DG540 W49.6513.8541.6512.97≈20.9%504 WDec 13, 2021
VSUN545-144BMH-DG545 W49.8113.9241.8013.04≈21.1%509 WDec 13, 2021
VSUN550-144BMH-DG550 W49.9213.9942.0013.10≈21.3%514 WDec 13, 2021
VSUN555-144BMH-DG555 W50.0414.0742.1513.17≈21.5%519 WDec 13, 2021
VSUN560-144BMH-DG560 W50.1414.1642.2413.26≈21.7%524 WDec 13, 2021
≈ efficiency = Pmax ÷ CEC-listed area 2.02 m².

Build & dimensions

CEC PV Module List (Oct 7, 2026)

Heat & cold behaviour

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation
CEC listing test
Pmax coefficient γ−0.331 %/°C
Voc coefficient β−0.265 %/°C
Isc coefficient α+0.052 %/°C
Operating cell temperatureNOCT 46.2 °C
Vmp coefficient ≈ γ − α (CEC); used only for the hot-roof voltage estimate.

Away from lab conditions — CEC listing test points

ClassPmax at NOCTVmp × Imp at NOCTPmax at 200 W/m²Low-light efficiency vs STC
380 W282.8 W37.33 V × 7.57 A72.4 W95%
385 W286.3 W37.52 V × 7.63 A73.3 W95%
390 W289.8 W37.7 V × 7.69 A74.2 W95%
395 W293.6 W37.89 V × 7.75 A75.2 W95%
400 W297.2 W38.08 V × 7.81 A76.1 W95%
405 W301.1 W38.26 V × 7.87 A77.1 W95%
410 W304.7 W38.45 V × 7.93 A78 W95%
430 W327.2 W38.18 V × 8.57 A87.6 W102%
435 W331 W38.37 V × 8.63 A88.6 W102%
440 W334.8 W38.56 V × 8.68 A89.6 W102%
445 W338.6 W38.75 V × 8.74 A90.7 W102%
450 W342.5 W38.94 V × 8.8 A91.7 W102%
455 W346.4 W39.12 V × 8.85 A92.7 W102%
460 W349.9 W39.31 V × 8.9 A93.7 W102%
520 W389.3 W38.6 V × 10.09 A100.6 W97%
525 W393.1 W38.7 V × 10.16 A101.6 W97%
530 W396.9 W38.83 V × 10.22 A102.6 W97%
535 W400.8 W38.97 V × 10.29 A103.6 W97%
540 W404.4 W39.11 V × 10.34 A104.5 W97%
545 W408.1 W39.25 V × 10.4 A105.5 W97%
550 W411.9 W39.44 V × 10.44 A106.5 W97%
555 W415.6 W39.58 V × 10.5 A107.4 W97%
560 W419.3 W39.66 V × 10.57 A108.4 W97%
Pmax = Vmp × Imp from the CEC listing; low-light efficiency = Pmax at 200 W/m² ÷ (20% of STC Pmax).

Independent reliability testing

Kiwa PVEL Scorecard · RETC PV Module Index
2023, 2024
PVEL Top Performer
this series
6
Tests passed as Top Performer
DH, HSS, LID+LETID, MSS, PID, TC
6
PVEL Scorecards
VSUN (Vietnam Sunergy) named Top Performer, 2021–2026
2025, 2026
RETC Overall Highest Achiever
VSUN (Vietnam Sunergy), manufacturer level

PVEL Top Performer tests

YearProductTests
2023VSUNxxx-144BMH-DGDHLID+LETIDMSSPIDTC
2024VSUNxxx-144BMH-DGDHHSSLID+LETIDMSSPIDTC
2023VSUNxxx-144BMH (closely related product name)DHLID+LETIDMSSPIDTC
2024VSUNxxx-144BMH (closely related product name)HSSLID+LETIDPID
2023VSUNxxx-144BMH-DG (M6) (closely related product name)DHLID+LETIDMSSPIDTC

Tested bill of materials

Details describe the tested sample, not every module of the series.

RETC PV Module Index — VSUN (Vietnam Sunergy)

YearRecognition
2024Test Category High Achiever
2025Overall Highest Achiever
2026Overall Highest Achiever; High achievement in performance; High achievement in reliability; Performance discipline high achiever (Lid, PAN file, Temperature coefficient, Iam, Letid); Quality discipline high achiever (BOM verification); Reliability discipline high achiever (Damp heat, Pid, Sdml, Tc, Uvid)

Inverter compatibility & string sizing

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation · NLR PVWatts v8 · inverter datasheets · NLR SAM inverter library · CEC Grid Support Inverter List (Oct 7, 2026)
52.4 V
Voc when cold
per panel
33.5 V
Vmp when hot
per panel
11
Max panels / string
max DC 600 V
2
Min panels / string
MPPT from 60 V
Defaults come from NLR TMY weather (coldest hour, hottest modeled cell). Code calculations (NEC 690.7) use the ASHRAE extreme annual minimum, which is usually colder — enter it above. β is the CEC-measured coefficient; NEC 690.7 calculations use the datasheet value.

String inverters most named in SoCal permits

InverterMax DC inputMPPTWindow sourcePanels per string
Tesla 1538000-xx-y600 V60–480 Vdatasheet2–11
Solis (Ginlong) S6-EH1P10K-H-US600 V80–520 Vdatasheet3–11
Solis (Ginlong) Solis-1P7.6K-4G-US600 V100–500 Vdatasheet3–11
Qcells Q.VOLT H7.6SX498 V234–498 VCEC test window7–9

Microinverters (one per panel)

MicroinverterRecommended module powerMax DC inputMPPTVoc cold / Vmp hotCheckDC/AC
Enphase IQ8X-80-M-US320–540 W79.5 V43–60 V52.4 / 33.5 V✗ Not a match: module voltage below MPPT range1.18
APsystems (Alt Power System) DS3-L265–570 W60 V28–45 V52.4 / 33.5 V✓ Within range0.58
Enphase IQ8M-72-2-US260–460 W60 V30–45 V52.4 / 33.5 V✓ Within range1.38
Enphase IQ8A-72-2-US295–500 W60 V32–45 V52.4 / 33.5 V✓ Within range1.29
Voltage check against the microinverter datasheets — confirm the pairing on the manufacturer’s module compatibility list. Rows appear only when the panel’s power is inside the microinverter’s recommended module power range.
SolarEdge and other optimizer-based systems size strings by the optimizer rules — use the manufacturer’s designer. Reference inverters: most named in SoCal permits since Oct 2024.

Expected production in Southern California

NLR PVWatts v8 · Cali-Graf calculation
CitykWh / kW / yrkWh / panel / yrkWh / system / yrSun, kWh/m²/day
Los Angeles1,67675412,0676.08
Palmdale1,83582613,2126.69
Chula Vista1,69676312,2116.11
Huntington Beach1,64373911,8305.89
Riverside1,69676312,2116.21
Santa Clarita1,72477612,4136.28
788Jan788Feb1,012Mar1,117Apr1,104May1,173Jun1,236Jul1,250Aug1,093Sep964Oct829Nov717DeckWh per month · Los Angeles
Estimate for comparison, not a quote: shading, roof orientation and local losses change real output. Roof mount, 20° tilt, south, 14% system losses.

Compare with similar 450 W panels

CEC PV Module List (Oct 7, 2026) · datasheets · Kiwa PVEL Scorecard · building permits
PanelPmaxEfficiencyγ Pmax (CEC)Voc, VIsc, APVEL (product / brand)SoCal permits (series)
VSUN (Vietnam Sunergy) VSUN450-144BMH-DG450 W≈20.4%−0.33149.411.52product 2023, 2024—
Qcells Q.TRON BLK M-G2+ 445445 W≈22.8%−0.27640.1613.98brand 11× (2016–2026)40
Hyundai Energy Solutions HiN-T450NF(BK)450 W≈23.2%−0.29839.214.53brand 5× (2017–2025)37
REC Group REC450AA Pure-RX450 W≈22.3%−0.24865.18.81brand 9× (2016–2025)33
Same fields from the same sources for every row; ≈ efficiency is calculated from the listed area. Comparable series: other brands, same product group, power range covering this class.

About VSUN (Vietnam Sunergy)

CEC PV Module List (Oct 7, 2026) · Kiwa PVEL Scorecard · RETC PV Module Index · building permits

Other series by SoCal permits

VSUNxxxN-108BMH-BB · 4VSUNxxxN-108MH-BB · 3VSUNxxxN-144MH · 1VSUNxxx-108BMH · 1VSUNxxx-108M-BB · 1VSUNxxxN-108BMH

Questions & answers

How efficient is the VSUN (Vietnam Sunergy) VSUN450-144BMH-DG?

Calculated from the panel area (2.2 m²): about 20.4% for the 450 W class. 450 W over 2.2 m² equals about 204 W per square meter.

How much energy does one panel produce in Los Angeles or Palmdale?

PVWatts v8 with typical-year weather gives about 754 kWh per year per 450 W panel in Los Angeles and about 826 kWh in Palmdale (20° roof, facing south, 14% system losses).

How much power does it lose on a hot roof?

With γ = −0.331 %/°C, at a 77 °C cell temperature (hottest modeled hour in Palmdale) output is about 17.1% below the STC rating.

How many panels fit on one string?

With the Tesla 1538000-xx-y (max DC 600 V, MPPT from 60 V, datasheet) in Los Angeles the calculator gives 2–11 panels per string (Voc at 2 °C = 52.4 V, Vmp at 74 °C cell = 33.5 V). Final design must follow the inverter manual and NEC 690.7.

Does it work with APsystems (Alt Power System) DS3-L microinverters?

Voltage check against the APsystems (Alt Power System) datasheet: Voc when cold 52.4 V vs max input 60 V; Vmp when hot 33.5 V vs MPPT low 28 V; recommended module power 265–570 W. Confirm on the microinverter maker’s compatibility list.

Is it bifacial?

Yes. Rear gain depends on mounting height and ground reflectance.

Has this panel been reliability-tested?

VSUNxxx-144BMH-DG was a PVEL Top Performer in 2023, 2024 (DH, HSS, LID+LETID, MSS, PID, TC).

Sources

  1. California Energy Commission — Solar Equipment Lists, PV Module List, Inverter List (snapshot Oct 7, 2026).
  2. Qcells — manufacturer datasheet “Q.TRON BLK M-G2+ SERIES 415–440 Wp”.
  3. Hyundai Energy Solutions — datasheet [US] NF(BK)(HiN) Series (N TOPCon Bifacial) 435~445W.
  4. Kiwa PVEL — PV Module Reliability Scorecard, Top Performer lists 2021–2026.
  5. RETC — PV Module Index reports 2024–2026.
  6. NLR (formerly NREL) — System Advisor Model CEC module and inverter libraries (version 2026.7.3).
  7. NLR (formerly NREL) — PVWatts v8, NSRDB PSM v3 typical-year weather for Los Angeles, Palmdale, Chula Vista, Huntington Beach, Riverside, Santa Clarita.
  8. Inverter datasheets — APsystems (Alt Power System), Enphase, Solis (Ginlong), Tesla (manufacturer documents).
  9. Building permits — Southern California permit portals. Equipment matched from permit descriptions.
  10. Cali-Graf calculations — formulas and inputs are shown next to each calculated value (efficiency from area, temperature-corrected voltages, string sizing, energy estimates).