Cali-GrafCali-Graf
Solar panelVSUN (Vietnam Sunergy)

VSUN (Vietnam Sunergy) VSUN360-120M-BW

120 half-cut cells. Power classes 315–455 W in the CEC list.

CEC listed · Apr 13, 2020UL 61730
Power class
  • Power (STC)360 WCEC nameplate
  • Efficiency≈19.7%calculated from area
  • %/°C Pmax−0.371CEC listing test
  • PTC / STC92.8%PTC 334 W (CEC)

Power classes

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation · 17 models
ModelPmaxVoc, VIsc, AVmp, VImp, AEfficiencyPTCCEC listed
VSUN315-120M-BW315 W39.9010.0833.109.52≈18.7%291 WApr 13, 2020
VSUN320-120M-BW320 W40.2010.1733.309.61≈19.0%296 WApr 13, 2020
VSUN325-120M-BW325 W40.4010.2833.509.71≈19.3%301 WApr 13, 2020
VSUN330-120M-BW330 W40.6010.3533.709.80≈19.6%305 WApr 13, 2020
VSUN335-120M-BW335 W40.8010.4233.909.89≈19.9%310 WApr 13, 2020
VSUN340-120M-BW340 W41.0010.5234.109.98≈20.2%315 WApr 13, 2020
VSUN350-120M-BW350 W41.4010.7834.5010.15≈19.1%324 WMay 3, 2021
VSUN355-120M-BW355 W40.3011.2633.8010.51≈19.4%329 WMay 3, 2021
VSUN360-120M-BW360 W40.5011.3534.0010.59≈19.7%334 WMay 3, 2021
VSUN365-120M-BW365 W40.7011.4334.2010.68≈19.9%339 WMay 3, 2021
VSUN370-120M-BW370 W40.9011.5234.4010.76≈20.2%343 WMay 3, 2021
VSUN430-120M-BW430 W41.3413.2534.3012.54≈20.0%395 WJan 3, 2022
VSUN435-120M-BW435 W41.5213.3334.4512.63≈20.2%400 WJan 3, 2022
VSUN440-120M-BW440 W41.7013.4134.6012.72≈20.5%405 WJan 3, 2022
VSUN445-120M-BW445 W41.9013.4834.8012.79≈20.7%409 WJan 3, 2022
VSUN450-120M-BW450 W42.1013.5635.0012.86≈20.9%414 WJan 3, 2022
VSUN455-120M-BW455 W42.3013.6335.2012.93≈21.2%419 WJan 3, 2022
≈ efficiency = Pmax ÷ CEC-listed area 1.68 m².

Build & dimensions

CEC PV Module List (Oct 7, 2026)

Heat & cold behaviour

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation
CEC listing test
Pmax coefficient γ−0.371 %/°C
Voc coefficient β−0.289 %/°C
Isc coefficient α+0.056 %/°C
Operating cell temperatureNOCT 45.2 °C
Vmp coefficient ≈ γ − α (CEC); used only for the hot-roof voltage estimate.

Away from lab conditions — CEC listing test points

ClassPmax at NOCTVmp × Imp at NOCTPmax at 200 W/m²Low-light efficiency vs STC
315 W232.4 W31.1 V × 7.47 A59.3 W94%
320 W236 W31.28 V × 7.55 A60.3 W94%
325 W239.9 W31.47 V × 7.62 A61.2 W94%
330 W243.6 W31.66 V × 7.69 A62.2 W94%
335 W247.3 W31.85 V × 7.77 A63.1 W94%
340 W251 W32.03 V × 7.84 A64.1 W94%
350 W260.2 W32.46 V × 8.02 A68.7 W98%
355 W263.9 W31.8 V × 8.3 A69.7 W98%
360 W267.5 W31.99 V × 8.36 A70.7 W98%
365 W271.4 W32.18 V × 8.43 A71.7 W98%
370 W275 W32.36 V × 8.5 A72.6 W98%
430 W319.6 W31.66 V × 10.09 A86.1 W100%
435 W323.3 W31.8 V × 10.17 A87.1 W100%
440 W327 W31.93 V × 10.24 A88.1 W100%
445 W330.7 W32.12 V × 10.3 A89.1 W100%
450 W334.4 W32.3 V × 10.35 A90.1 W100%
455 W338.2 W32.49 V × 10.41 A91.1 W100%
Pmax = Vmp × Imp from the CEC listing; low-light efficiency = Pmax at 200 W/m² ÷ (20% of STC Pmax).

Independent reliability testing

Kiwa PVEL Scorecard · RETC PV Module Index
6
PVEL Scorecards
VSUN (Vietnam Sunergy) named Top Performer, 2021–2026
2025, 2026
RETC Overall Highest Achiever
VSUN (Vietnam Sunergy), manufacturer level
This exact series is not listed in published PVEL Top Performer tables. Results below are for the manufacturer.

RETC PV Module Index — VSUN (Vietnam Sunergy)

YearRecognition
2024Test Category High Achiever
2025Overall Highest Achiever
2026Overall Highest Achiever; High achievement in performance; High achievement in reliability; Performance discipline high achiever (Lid, PAN file, Temperature coefficient, Iam, Letid); Quality discipline high achiever (BOM verification); Reliability discipline high achiever (Damp heat, Pid, Sdml, Tc, Uvid)

Inverter compatibility & string sizing

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation · NLR PVWatts v8 · inverter datasheets · NLR SAM inverter library · CEC Grid Support Inverter List (Oct 7, 2026)
43.2 V
Voc when cold
per panel
26.9 V
Vmp when hot
per panel
13
Max panels / string
max DC 600 V
3
Min panels / string
MPPT from 60 V
Defaults come from NLR TMY weather (coldest hour, hottest modeled cell). Code calculations (NEC 690.7) use the ASHRAE extreme annual minimum, which is usually colder — enter it above. β is the CEC-measured coefficient; NEC 690.7 calculations use the datasheet value.

String inverters most named in SoCal permits

InverterMax DC inputMPPTWindow sourcePanels per string
Tesla 1538000-xx-y600 V60–480 Vdatasheet3–13
Solis (Ginlong) S6-EH1P10K-H-US600 V80–520 Vdatasheet3–13
Solis (Ginlong) Solis-1P7.6K-4G-US600 V100–500 Vdatasheet4–13
Qcells Q.VOLT H7.6SX498 V234–498 VCEC test window9–11

Microinverters (one per panel)

MicroinverterRecommended module powerMax DC inputMPPTVoc cold / Vmp hotCheckDC/AC
Enphase IQ8PLUS-72-2-US235–440 W60 V29–45 V43.2 / 26.9 V⚠ Works; below MPPT at peak heat1.24
Enphase IQ8X-80-M-US320–540 W79.5 V43–60 V43.2 / 26.9 V✗ Not a match: module voltage below MPPT range0.95
APsystems (Alt Power System) DS3-L265–570 W60 V28–45 V43.2 / 26.9 V⚠ Works; below MPPT at peak heat0.46
Enphase IQ8M-72-2-US260–460 W60 V30–45 V43.2 / 26.9 V⚠ Works; below MPPT at peak heat1.11
Enphase IQ8A-72-2-US295–500 W60 V32–45 V43.2 / 26.9 V⚠ Works; below MPPT at peak heat1.03
Voltage check against the microinverter datasheets — confirm the pairing on the manufacturer’s module compatibility list. Rows appear only when the panel’s power is inside the microinverter’s recommended module power range.
SolarEdge and other optimizer-based systems size strings by the optimizer rules — use the manufacturer’s designer. Reference inverters: most named in SoCal permits since Oct 2024.

Expected production in Southern California

NLR PVWatts v8 · Cali-Graf calculation
CitykWh / kW / yrkWh / panel / yrkWh / system / yrSun, kWh/m²/day
Los Angeles1,67660311,4646.08
Palmdale1,83566112,5516.69
Chula Vista1,69661111,6016.11
Huntington Beach1,64359111,2385.89
Riverside1,69661111,6016.21
Santa Clarita1,72462111,7926.28
748Jan749Feb961Mar1,062Apr1,049May1,114Jun1,174Jul1,187Aug1,038Sep916Oct787Nov681DeckWh per month · Los Angeles
Estimate for comparison, not a quote: shading, roof orientation and local losses change real output. Roof mount, 20° tilt, south, 14% system losses.

Compare with similar 360 W panels

CEC PV Module List (Oct 7, 2026) · Kiwa PVEL Scorecard · building permits
PanelPmaxEfficiencyγ Pmax (CEC)Voc, VIsc, APVEL (product / brand)SoCal permits (series)
VSUN (Vietnam Sunergy) VSUN360-120M-BW360 W≈19.7%−0.37140.511.35brand 6×—
LONGi LR4-60HPB-360M360 W≈20.3%−0.33940.811.33product 2021, 2022193
REC Group REC360AA360 W≈21.4%−0.27944.110.23brand 9× (2016–2025)30
Trina Solar TSM-360DE06X.05(II)360 W≈19.8%−0.33944.810.3product 202223
Same fields from the same sources for every row; ≈ efficiency is calculated from the listed area. Comparable series: other brands, same product group, power range covering this class.

About VSUN (Vietnam Sunergy)

CEC PV Module List (Oct 7, 2026) · Kiwa PVEL Scorecard · RETC PV Module Index · building permits

Other series by SoCal permits

VSUNxxxN-108BMH-BB · 4VSUNxxxN-108MH-BB · 3VSUNxxxN-144MH · 1VSUNxxx-108BMH · 1VSUNxxx-108M-BB · 1VSUNxxxN-108BMH

Questions & answers

How efficient is the VSUN (Vietnam Sunergy) VSUN360-120M-BW?

Calculated from the panel area (1.83 m²): about 19.7% for the 360 W class. 360 W over 1.83 m² equals about 197 W per square meter.

How much energy does one panel produce in Los Angeles or Palmdale?

PVWatts v8 with typical-year weather gives about 603 kWh per year per 360 W panel in Los Angeles and about 661 kWh in Palmdale (20° roof, facing south, 14% system losses).

How much power does it lose on a hot roof?

With γ = −0.371 %/°C, at a 77 °C cell temperature (hottest modeled hour in Palmdale) output is about 19.2% below the STC rating.

How many panels fit on one string?

With the Tesla 1538000-xx-y (max DC 600 V, MPPT from 60 V, datasheet) in Los Angeles the calculator gives 3–13 panels per string (Voc at 2 °C = 43.2 V, Vmp at 74 °C cell = 26.9 V). Final design must follow the inverter manual and NEC 690.7.

Has this panel been reliability-tested?

This exact series is not in published PVEL Top Performer tables; VSUN (Vietnam Sunergy) was named a Top Performer in 6 Scorecards (2021–2026). RETC named VSUN (Vietnam Sunergy) Overall Highest Achiever in 2025, 2026.

Sources

  1. California Energy Commission — Solar Equipment Lists, PV Module List, Inverter List (snapshot Oct 7, 2026).
  2. Kiwa PVEL — PV Module Reliability Scorecard, Top Performer lists 2021–2026.
  3. RETC — PV Module Index reports 2024–2026.
  4. NLR (formerly NREL) — System Advisor Model CEC inverter library (version 2026.7.3).
  5. NLR (formerly NREL) — PVWatts v8, NSRDB PSM v3 typical-year weather for Los Angeles, Palmdale, Chula Vista, Huntington Beach, Riverside, Santa Clarita.
  6. Inverter datasheets — APsystems (Alt Power System), Enphase, Solis (Ginlong), Tesla (manufacturer documents).
  7. Building permits — Southern California permit portals. Equipment matched from permit descriptions.
  8. Cali-Graf calculations — formulas and inputs are shown next to each calculated value (efficiency from area, temperature-corrected voltages, string sizing, energy estimates).