Cali-GrafCali-Graf
Solar panelVenus Energy

Venus Energy VE-395-54IIMJ

108 half-cut cells. Power classes 380–415 W in the CEC list.

CEC listed · Jul 11, 2023UL 61730
Power class
  • Power (STC)395 WCEC nameplate
  • Efficiency≈20.3%calculated from area
  • %/°C Pmax−0.343CEC listing test
  • PTC / STC94%PTC 371 W (CEC)

Power classes

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation · 8 models
ModelPmaxVoc, VIsc, AVmp, VImp, AEfficiencyPTCCEC listed
VE-380-54IIMJ380 W36.0513.4130.0412.65≈19.5%357 WJul 11, 2023
VE-385-54IIMJ385 W36.1913.5330.1612.77≈19.7%362 WJul 11, 2023
VE-390-54IIMJ390 W36.3413.6530.2812.88≈20.0%366 WJul 11, 2023
VE-395-54IIMJ395 W36.5113.7630.4212.98≈20.3%371 WJul 11, 2023
VE-400-54IIMJ400 W36.6413.8930.5413.10≈20.5%376 WJul 11, 2023
VE-405-54IIMJ405 W36.8014.0030.6713.21≈20.8%381 WJul 11, 2023
VE-410-54IIMJ410 W36.9314.1230.7813.32≈21.0%386 WJul 11, 2023
VE-415-54IIMJ415 W37.0514.2130.8913.43≈21.3%391 WJul 11, 2023
≈ efficiency = Pmax ÷ CEC-listed area 1.95 m².

Heat & cold behaviour

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation
CEC listing test
Pmax coefficient γ−0.343 %/°C
Voc coefficient β−0.254 %/°C
Isc coefficient α+0.034 %/°C
Operating cell temperatureNOCT 43.2 °C
Vmp coefficient ≈ γ − α (CEC); used only for the hot-roof voltage estimate.

Away from lab conditions — CEC listing test points

ClassPmax at NOCTVmp × Imp at NOCTPmax at 200 W/m²Low-light efficiency vs STC
380 W288.3 W28.2 V × 10.22 A73.4 W97%
385 W292.2 W28.31 V × 10.32 A74.4 W97%
390 W295.9 W28.42 V × 10.41 A75.3 W97%
395 W299.5 W28.55 V × 10.49 A76.2 W97%
400 W303.5 W28.67 V × 10.59 A77.3 W97%
405 W307.4 W28.79 V × 10.68 A78.2 W97%
410 W311 W28.89 V × 10.77 A79.2 W97%
415 W314.7 W29 V × 10.85 A80.1 W97%
Pmax = Vmp × Imp from the CEC listing; low-light efficiency = Pmax at 200 W/m² ÷ (20% of STC Pmax).

Inverter compatibility & string sizing

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation · NLR PVWatts v8 · inverter datasheets · NLR SAM inverter library · CEC Grid Support Inverter List (Oct 7, 2026)
38.6 V
Voc when cold
per panel
24.8 V
Vmp when hot
per panel
15
Max panels / string
max DC 600 V
3
Min panels / string
MPPT from 60 V
Defaults come from NLR TMY weather (coldest hour, hottest modeled cell). Code calculations (NEC 690.7) use the ASHRAE extreme annual minimum, which is usually colder — enter it above. β is the CEC-measured coefficient; NEC 690.7 calculations use the datasheet value.

String inverters most named in SoCal permits

InverterMax DC inputMPPTWindow sourcePanels per string
Tesla 1538000-xx-y600 V60–480 Vdatasheet3–15
Solis (Ginlong) S6-EH1P10K-H-US600 V80–520 Vdatasheet4–15
Solis (Ginlong) Solis-1P7.6K-4G-US600 V100–500 Vdatasheet5–15
Qcells Q.VOLT H7.6SX498 V234–498 VCEC test window10–12

Microinverters (one per panel)

MicroinverterRecommended module powerMax DC inputMPPTVoc cold / Vmp hotCheckDC/AC
Enphase IQ8PLUS-72-2-US235–440 W60 V29–45 V38.6 / 24.8 V⚠ Works; below MPPT at peak heat1.36
Enphase IQ8X-80-M-US320–540 W79.5 V43–60 V38.6 / 24.8 V✗ Not a match: module voltage below MPPT range1.04
APsystems (Alt Power System) DS3-L265–570 W60 V28–45 V38.6 / 24.8 V⚠ Works; below MPPT at peak heat0.51
Enphase IQ8M-72-2-US260–460 W60 V30–45 V38.6 / 24.8 V⚠ Works; below MPPT at peak heat1.22
Enphase IQ8A-72-2-US295–500 W60 V32–45 V38.6 / 24.8 V✗ Not a match: module voltage below MPPT range1.13
Voltage check against the microinverter datasheets — confirm the pairing on the manufacturer’s module compatibility list. Rows appear only when the panel’s power is inside the microinverter’s recommended module power range.
SolarEdge and other optimizer-based systems size strings by the optimizer rules — use the manufacturer’s designer. Reference inverters: most named in SoCal permits since Oct 2024.

Expected production in Southern California

NLR PVWatts v8 · Cali-Graf calculation
CitykWh / kW / yrkWh / panel / yrkWh / system / yrSun, kWh/m²/day
Los Angeles1,67666211,9166.08
Palmdale1,83572513,0476.69
Chula Vista1,69667012,0596.11
Huntington Beach1,64364911,6825.89
Riverside1,69667012,0596.21
Santa Clarita1,72468112,2586.28
778Jan779Feb999Mar1,103Apr1,090May1,158Jun1,220Jul1,234Aug1,079Sep952Oct818Nov708DeckWh per month · Los Angeles
Estimate for comparison, not a quote: shading, roof orientation and local losses change real output. Roof mount, 20° tilt, south, 14% system losses.

Compare with similar 395 W panels

CEC PV Module List (Oct 7, 2026) · Qcells datasheet · Kiwa PVEL Scorecard · building permits
PanelPmaxEfficiencyγ Pmax (CEC)Voc, VIsc, APVEL (product / brand)SoCal permits (series)
Venus Energy VE-395-54IIMJ395 W≈20.3%−0.34336.5113.76——
Qcells Q.PEAK DUO BLK ML-G10+ 395395 W≥20.1%−0.36245.2711.1product 2022, 2023221
JA Solar JAM54S31-395/MR395 W≈20.8%−0.32936.9813.7product 2023, 2024152
REC Group REC395AA Pure395 W≈22%−0.25648.710.2brand 9× (2016–2025)66
Same fields from the same sources for every row; ≈ efficiency is calculated from the listed area. Comparable series: other brands, same product group, power range covering this class.

Questions & answers

How efficient is the Venus Energy VE-395-54IIMJ?

Calculated from the panel area (1.95 m²): about 20.3% for the 395 W class. 395 W over 1.95 m² equals about 203 W per square meter.

How much energy does one panel produce in Los Angeles or Palmdale?

PVWatts v8 with typical-year weather gives about 662 kWh per year per 395 W panel in Los Angeles and about 725 kWh in Palmdale (20° roof, facing south, 14% system losses).

How much power does it lose on a hot roof?

With γ = −0.343 %/°C, at a 77 °C cell temperature (hottest modeled hour in Palmdale) output is about 17.8% below the STC rating.

How many panels fit on one string?

With the Tesla 1538000-xx-y (max DC 600 V, MPPT from 60 V, datasheet) in Los Angeles the calculator gives 3–15 panels per string (Voc at 2 °C = 38.6 V, Vmp at 74 °C cell = 24.8 V). Final design must follow the inverter manual and NEC 690.7.

Sources

  1. California Energy Commission — Solar Equipment Lists, PV Module List, Inverter List (snapshot Oct 7, 2026).
  2. Qcells — manufacturer datasheet “Q.PEAK DUO BLK ML-G10+ ENDURING HIGH PERFORMANCE”.
  3. Kiwa PVEL — PV Module Reliability Scorecard, Top Performer lists.
  4. NLR (formerly NREL) — System Advisor Model CEC inverter library (version 2026.7.3).
  5. NLR (formerly NREL) — PVWatts v8, NSRDB PSM v3 typical-year weather for Los Angeles, Palmdale, Chula Vista, Huntington Beach, Riverside, Santa Clarita.
  6. Inverter datasheets — APsystems (Alt Power System), Enphase, Solis (Ginlong), Tesla (manufacturer documents).
  7. Building permits — Southern California permit portals. Equipment matched from permit descriptions.
  8. Cali-Graf calculations — formulas and inputs are shown next to each calculated value (efficiency from area, temperature-corrected voltages, string sizing, energy estimates).