Cali-GrafCali-Graf
Solar panelURE (United Renewable Energy)

URE (United Renewable Energy) FBM400MFG-BB

108 half-cut cells. Power classes 390–410 W in the CEC list; datasheet covers 390–405 W.

CEC listed · Feb 1, 2022UL 6173025-yr product + 25-yr performance warrantyInstalled in 9 SoCal permits
Power class
  • Power (STC)400 WCEC nameplate
  • Efficiency≥20.5%datasheet minimum
  • %/°C Pmax−0.32CEC test: −0.404
  • Output at year 2580%performance warranty

Power classes

CEC PV Module List (Oct 7, 2026) · URE (United Renewable Energy) datasheet · Cali-Graf calculation · 5 models
ModelPmaxVoc, VIsc, AVmp, VImp, AEfficiencyPTCCEC listed
FBM390MFG-BB390 W36.8413.5030.8212.66≥20.0%358 WFeb 1, 2022
FBM395MFG-BB395 W37.0313.5931.0012.75≥20.2%363 WFeb 1, 2022
FBM400MFG-BB400 W37.2013.6831.1712.84≥20.5%368 WFeb 1, 2022
FBM405MFG-BB405 W37.3613.7831.3612.92≥20.8%373 WFeb 1, 2022
FBM410MFG-BB410 W37.5413.8631.5513.00≈21.0%377 WFeb 1, 2022
≈ efficiency = Pmax ÷ panel area 1.952 m² (datasheet size) for classes outside the datasheet.

Build & dimensions

URE (United Renewable Energy) datasheets · Cali-Graf calculation · CEC PV Module List (Oct 7, 2026)

Heat & cold behaviour

URE (United Renewable Energy) datasheet · CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation
DatasheetCEC listing test
Pmax coefficient γ−0.32 %/°C−0.404 %/°C
Voc coefficient β−0.27 %/°C−0.312 %/°C
Isc coefficient α+0.05 %/°C+0.063 %/°C
Vmp coefficient≈ −0.37 %/°C—
Operating cell temperatureNMOT 45 ± 2 °CNOCT 45.8 °C
Vmp coefficient ≈ γ − α (datasheet); used only for the hot-roof voltage estimate.

Away from lab conditions — CEC listing test points

ClassPmax at NOCTVmp × Imp at NOCTPmax at 200 W/m²Low-light efficiency vs STC
390 W289.3 W28.58 V × 10.12 A77.7 W100%
395 W293 W28.75 V × 10.19 A78.7 W100%
400 W296.7 W28.9 V × 10.27 A79.7 W100%
405 W300.4 W29.08 V × 10.33 A80.7 W100%
410 W304.1 W29.25 V × 10.39 A81.7 W100%
Pmax = Vmp × Imp from the CEC listing; low-light efficiency = Pmax at 200 W/m² ÷ (20% of STC Pmax).

Electrical & strength ratings

Certifications

CEC PV Module List (Oct 7, 2026) · URE (United Renewable Energy) datasheet
UL 61730IEC 61215IEC 61730

Inverter compatibility & string sizing

URE (United Renewable Energy) datasheet · Cali-Graf calculation · NLR PVWatts v8 · CEC PV Module List (Oct 7, 2026) · inverter datasheets · NLR SAM inverter library · CEC Grid Support Inverter List (Oct 7, 2026)
39.5 V
Voc when cold
per panel
25.5 V
Vmp when hot
per panel
15
Max panels / string
max DC 600 V
3
Min panels / string
MPPT from 60 V
Defaults come from NLR TMY weather (coldest hour, hottest modeled cell). Code calculations (NEC 690.7) use the ASHRAE extreme annual minimum, which is usually colder — enter it above.

String inverters most named in SoCal permits

InverterMax DC inputMPPTWindow sourcePanels per string
Tesla 1538000-xx-y600 V60–480 Vdatasheet3–15
Solis (Ginlong) S6-EH1P10K-H-US600 V80–520 Vdatasheet4–15
Solis (Ginlong) Solis-1P7.6K-4G-US600 V100–500 Vdatasheet4–15
Qcells Q.VOLT H7.6SX498 V234–498 VCEC test window10–12

Microinverters (one per panel)

MicroinverterRecommended module powerMax DC inputMPPTVoc cold / Vmp hotCheckDC/AC
Enphase IQ8PLUS-72-2-US235–440 W60 V29–45 V39.5 / 25.5 V⚠ Works; below MPPT at peak heat1.38
Enphase IQ8X-80-M-US320–540 W79.5 V43–60 V39.5 / 25.5 V✗ Not a match: module voltage below MPPT range1.05
APsystems (Alt Power System) DS3-L265–570 W60 V28–45 V39.5 / 25.5 V⚠ Works; below MPPT at peak heat0.51
Enphase IQ8M-72-2-US260–460 W60 V30–45 V39.5 / 25.5 V⚠ Works; below MPPT at peak heat1.23
Enphase IQ8A-72-2-US295–500 W60 V32–45 V39.5 / 25.5 V✗ Not a match: module voltage below MPPT range1.15
Voltage check against the microinverter datasheets — confirm the pairing on the manufacturer’s module compatibility list. Rows appear only when the panel’s power is inside the microinverter’s recommended module power range.
SolarEdge and other optimizer-based systems size strings by the optimizer rules — use the manufacturer’s designer. Reference inverters: most named in SoCal permits since Oct 2024.

Expected production in Southern California

NLR PVWatts v8 · Cali-Graf calculation
CitykWh / kW / yrkWh / panel / yrkWh / system / yrSun, kWh/m²/day
Los Angeles1,67667012,0676.08
Palmdale1,83573413,2126.69
Chula Vista1,69667812,2116.11
Huntington Beach1,64365711,8305.89
Riverside1,69667812,2116.21
Santa Clarita1,72469012,4136.28
788Jan788Feb1,012Mar1,117Apr1,104May1,173Jun1,236Jul1,250Aug1,093Sep964Oct829Nov717DeckWh per month · Los Angeles
Estimate for comparison, not a quote: shading, roof orientation and local losses change real output. Roof mount, 20° tilt, south, 14% system losses.

Who installs FBMxxxMFG-BB panels in SoCal

building permits
9
Permits naming this series
Feb 2023 – Feb 2026
1
Jurisdictions so far
LA County (unincorp.) (9)

Permits over time

2Q1 ’230Q2 ’231Q3 ’231Q4 ’232Q1 ’240Q2 ’241Q3 ’240Q4 ’240Q1 ’250Q2 ’250Q3 ’250Q4 ’252Q1 ’26permits per quarter

Typical system

median 8 kW, 19 panels (n = 6)

Only installer and ZIP level is shown — no homeowner names, street addresses or permit numbers. Permits from LA County (unincorp.) come without a contractor license, so they count toward totals but not toward installers. Counts grow as more permit portals are loaded.

Installed together with

building permits

Microinverters

Enphase IQ8+
2
Enphase IQ8M
2

Inverters

SolarEdge SE…H (HD-Wave)
3

Batteries

Enphase IQ Battery 10C
2
Number of permits naming both this panel series and the product; 8 of 9 permits list other equipment.

Compare with similar 400 W panels

CEC PV Module List (Oct 7, 2026) · Qcells datasheet · Kiwa PVEL Scorecard · building permits
PanelPmaxEfficiencyγ Pmax (CEC)Voc, VIsc, APVEL (product / brand)SoCal permits (series)
URE (United Renewable Energy) FBM400MFG-BB400 W≥20.5%−0.40437.213.68—9
Qcells Q.PEAK DUO BLK ML-G10+ 400400 W≥20.4%−0.36245.311.14product 2022, 2023221
JA Solar JAM54S31-400/MR400 W≈21.1%−0.32937.0713.79product 2023, 2024152
REC Group REC400AA Pure400 W≈22.3%−0.25648.810.25brand 9× (2016–2025)66
Same fields from the same sources for every row; ≈ efficiency is calculated from the listed area. Comparable series: other brands, same product group, power range covering this class.

Documents

manufacturer documents

Questions & answers

How efficient is the URE (United Renewable Energy) FBM400MFG-BB?

The URE (United Renewable Energy) datasheet guarantees at least 20.5% module efficiency for the 400 W class (up to 20.8% for 405 W). 400 W over 1.95 m² equals about 205 W per square meter.

How much energy does one panel produce in Los Angeles or Palmdale?

PVWatts v8 with typical-year weather gives about 670 kWh per year per 400 W panel in Los Angeles and about 734 kWh in Palmdale (20° roof, facing south, 14% system losses).

How much power does it lose on a hot roof?

With γ = −0.32 %/°C, at a 77 °C cell temperature (hottest modeled hour in Palmdale) output is about 16.6% below the STC rating.

How many panels fit on one string?

With the Tesla 1538000-xx-y (max DC 600 V, MPPT from 60 V, datasheet) in Los Angeles the calculator gives 3–15 panels per string (Voc at 2 °C = 39.5 V, Vmp at 74 °C cell = 25.5 V). Final design must follow the inverter manual and NEC 690.7.

What does the warranty cover?

25 years on the product and 25 years on performance: at least 80% after 25 years (manufacturer datasheet).

How big and heavy is it?

67.8 × 44.6 × 1.38 in (1,723 × 1,133 × 35 mm), 47.8 lb (21.7 kg).

Sources

  1. California Energy Commission — Solar Equipment Lists, PV Module List, Inverter List (snapshot Oct 7, 2026).
  2. URE (United Renewable Energy) — datasheet High Quality Solar Cell Technology allows URE to be major international exporter to Solar Module manufacturers in the United States and Europe..
  3. URE (United Renewable Energy) — datasheet 400 watt all black.
  4. Qcells — manufacturer datasheet “Q.PEAK DUO BLK ML-G10+ ENDURING HIGH PERFORMANCE”.
  5. URE (United Renewable Energy) — document library on the manufacturer’s website (links above).
  6. Kiwa PVEL — PV Module Reliability Scorecard, Top Performer lists.
  7. NLR (formerly NREL) — System Advisor Model CEC inverter library (version 2026.7.3).
  8. NLR (formerly NREL) — PVWatts v8, NSRDB PSM v3 typical-year weather for Los Angeles, Palmdale, Chula Vista, Huntington Beach, Riverside, Santa Clarita.
  9. Inverter datasheets — APsystems (Alt Power System), Enphase, Solis (Ginlong), Tesla (manufacturer documents).
  10. Building permits — Los Angeles County Public Works (EPIC-LA, unincorporated areas) (Feb 2023 – Feb 2026). Equipment matched from permit descriptions by model number.
  11. Cali-Graf calculations — formulas and inputs are shown next to each calculated value (efficiency from area, temperature-corrected voltages, string sizing, energy estimates).