144 cells, bifacial. Power classes 550–575 W in the CEC list.
| Model | Pmax | Voc, V | Isc, A | Vmp, V | Imp, A | Efficiency | PTC | CEC listed |
|---|---|---|---|---|---|---|---|---|
| FBF550D8G | 550 W | 50.30 | 14.02 | 41.60 | 13.22 | ≈21.3% | 517 W | Jul 22, 2024 |
| FBF555D8G | 555 W | 50.50 | 14.08 | 41.80 | 13.28 | ≈21.5% | 522 W | Jul 22, 2024 |
| FBF560D8G | 560 W | 50.70 | 14.13 | 42.00 | 13.34 | ≈21.7% | 527 W | Jul 22, 2024 |
| FBF565D8G | 565 W | 50.90 | 14.19 | 42.10 | 13.41 | ≈21.9% | 532 W | Jul 22, 2024 |
| FBF570D8G | 570 W | 51.10 | 14.25 | 42.30 | 13.48 | ≈22.1% | 537 W | Jul 22, 2024 |
| FBF575D8G | 575 W | 51.30 | 14.31 | 42.50 | 13.54 | ≈22.3% | 542 W | Jul 22, 2024 |
| CEC listing test | |
|---|---|
| Pmax coefficient γ | −0.305 %/°C |
| Voc coefficient β | −0.243 %/°C |
| Isc coefficient α | +0.037 %/°C |
| Operating cell temperature | NOCT 45.6 °C |
| Class | Pmax at NOCT | Vmp × Imp at NOCT | Pmax at 200 W/m² | Low-light efficiency vs STC |
|---|---|---|---|---|
| 550 W | 412.7 W | 40.9 V × 10.09 A | 105.8 W | 96% |
| 555 W | 416.3 W | 41.1 V × 10.13 A | 106.6 W | 96% |
| 560 W | 420.4 W | 41.3 V × 10.18 A | 107.4 W | 96% |
| 565 W | 423.5 W | 41.4 V × 10.23 A | 108.8 W | 96% |
| 570 W | 428.1 W | 41.6 V × 10.29 A | 109.7 W | 96% |
| 575 W | 431.8 W | 41.8 V × 10.33 A | 110.6 W | 96% |
| Inverter | Max DC input | MPPT | Window source | Panels per string |
|---|---|---|---|---|
| Tesla 1538000-xx-y | 600 V | 60–480 V | datasheet | 2–11 |
| Solis (Ginlong) S6-EH1P10K-H-US | 600 V | 80–520 V | datasheet | 3–11 |
| Solis (Ginlong) Solis-1P7.6K-4G-US | 600 V | 100–500 V | datasheet | 3–11 |
| Qcells Q.VOLT H7.6SX | 498 V | 234–498 V | CEC test window | 7–9 |
| Microinverter | Recommended module power | Max DC input | MPPT | Voc cold / Vmp hot | Check | DC/AC |
|---|---|---|---|---|---|---|
| APsystems (Alt Power System) DS3-L | 265–570 W | 60 V | 28–45 V | 53.5 / 35 V | ✓ Within range | 0.72 |
| City | kWh / kW / yr | kWh / panel / yr | kWh / system / yr | Sun, kWh/m²/day |
|---|---|---|---|---|
| Los Angeles | 1,676 | 939 | 11,263 | 6.08 |
| Palmdale | 1,835 | 1,028 | 12,331 | 6.69 |
| Chula Vista | 1,696 | 950 | 11,397 | 6.11 |
| Huntington Beach | 1,643 | 920 | 11,041 | 5.89 |
| Riverside | 1,696 | 950 | 11,397 | 6.21 |
| Santa Clarita | 1,724 | 965 | 11,585 | 6.28 |
| Panel | Pmax | Efficiency | γ Pmax (CEC) | Voc, V | Isc, A | SoCal permits (series) |
|---|---|---|---|---|---|---|
| URE (United Renewable Energy) FBF560D8G | 560 W | ≈21.7% | −0.305 | 50.7 | 14.13 | — |
| LONGi LR5-72HBD-560M | 560 W | ≈21.9% | −0.354 | 50.1 | 14.1 | 1 |
| Canadian Solar CS6W-555MB-AG | 555 W | ≈21.6% | −0.324 | 49.8 | 14.05 | 1 |
| AXITEC AC-555MH/144V | 555 W | ≥21.5% | −0.366 | 50.05 | 14.07 | 1 |
Calculated from the panel area (2.58 m²): about 21.7% for the 560 W class. 560 W over 2.58 m² equals about 217 W per square meter.
PVWatts v8 with typical-year weather gives about 939 kWh per year per 560 W panel in Los Angeles and about 1,028 kWh in Palmdale (20° roof, facing south, 14% system losses).
With γ = −0.305 %/°C, at a 77 °C cell temperature (hottest modeled hour in Palmdale) output is about 15.8% below the STC rating.
With the Tesla 1538000-xx-y (max DC 600 V, MPPT from 60 V, datasheet) in Los Angeles the calculator gives 2–11 panels per string (Voc at 2 °C = 53.5 V, Vmp at 74 °C cell = 35 V). Final design must follow the inverter manual and NEC 690.7.
Voltage check against the APsystems (Alt Power System) datasheet: Voc when cold 53.5 V vs max input 60 V; Vmp when hot 35 V vs MPPT low 28 V; recommended module power 265–570 W. Confirm on the microinverter maker’s compatibility list.
Yes. Rear gain depends on mounting height and ground reflectance.