Solar panelURE (United Renewable Energy)

URE (United Renewable Energy) FAK480CAG

156 half-cut cells, bifacial. Power classes 465–495 W in the CEC list.

CEC listed · Feb 22, 2022UL 61730Bifacial
Power class
  • Power (STC)480 WCEC nameplate
  • Efficiency≈20.1%calculated from area
  • %/°C Pmax−0.347CEC listing test
  • PTC / STC92.9%PTC 446 W (CEC)

Power classes

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation · 7 models
ModelPmaxVoc, VIsc, AVmp, VImp, AEfficiencyPTCCEC listed
FAK465CAG465 W52.5011.2243.7010.64≈19.5%432 WFeb 22, 2022
FAK470CAG470 W52.7011.2943.9010.71≈19.7%436 WFeb 22, 2022
FAK475CAG475 W52.9011.3544.1010.77≈19.9%441 WFeb 22, 2022
FAK480CAG480 W53.1011.4244.3010.84≈20.1%446 WFeb 22, 2022
FAK485CAG485 W53.3011.4844.5010.90≈20.3%451 WFeb 22, 2022
FAK490CAG490 W53.5011.5544.7010.97≈20.5%456 WFeb 22, 2022
FAK495CAG495 W53.7011.6244.9011.03≈20.7%460 WFeb 22, 2022
≈ efficiency = Pmax ÷ CEC-listed area 2.39 m².

Heat & cold behaviour

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation
CEC listing test
Pmax coefficient γ−0.347 %/°C
Voc coefficient β−0.284 %/°C
Isc coefficient α+0.057 %/°C
Operating cell temperatureNOCT 46.2 °C
Vmp coefficient ≈ γ − α (CEC); used only for the hot-roof voltage estimate.

Away from lab conditions — CEC listing test points

ClassPmax at NOCTVmp × Imp at NOCTPmax at 200 W/m²Low-light efficiency vs STC
465 W352.5 W41.64 V × 8.46 A93.7 W101%
470 W356.4 W41.83 V × 8.52 A94.7 W101%
475 W360.1 W42.02 V × 8.57 A95.7 W101%
480 W364.1 W42.22 V × 8.62 A96.7 W101%
485 W367.7 W42.41 V × 8.67 A97.7 W101%
490 W371.7 W42.6 V × 8.73 A98.8 W101%
495 W375.5 W42.79 V × 8.77 A99.7 W101%
Pmax = Vmp × Imp from the CEC listing; low-light efficiency = Pmax at 200 W/m² ÷ (20% of STC Pmax).

Inverter compatibility & string sizing

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation · NLR PVWatts v8 · inverter datasheets · NLR SAM inverter library · CEC Grid Support Inverter List (Oct 7, 2026)
56.6 V
Voc when cold
per panel
35.5 V
Vmp when hot
per panel
10
Max panels / string
max DC 600 V
2
Min panels / string
MPPT from 60 V
Defaults come from NLR TMY weather (coldest hour, hottest modeled cell). Code calculations (NEC 690.7) use the ASHRAE extreme annual minimum, which is usually colder — enter it above. β is the CEC-measured coefficient; NEC 690.7 calculations use the datasheet value.

String inverters most named in SoCal permits

InverterMax DC inputMPPTWindow sourcePanels per string
Tesla 1538000-xx-y600 V60–480 Vdatasheet2–10
Solis (Ginlong) S6-EH1P10K-H-US600 V80–520 Vdatasheet3–10
Solis (Ginlong) Solis-1P7.6K-4G-US600 V100–500 Vdatasheet3–10
Qcells Q.VOLT H7.6SX498 V234–498 VCEC test window7–8

Microinverters (one per panel)

MicroinverterRecommended module powerMax DC inputMPPTVoc cold / Vmp hotCheckDC/AC
Enphase IQ8X-80-M-US320–540 W79.5 V43–60 V56.6 / 35.5 V⚠ Works; below MPPT at peak heat1.26
APsystems (Alt Power System) DS3-L265–570 W60 V28–45 V56.6 / 35.5 V✓ Within range0.62
Enphase IQ8A-72-2-US295–500 W60 V32–45 V56.6 / 35.5 V✓ Within range1.38
Voltage check against the microinverter datasheets — confirm the pairing on the manufacturer’s module compatibility list. Rows appear only when the panel’s power is inside the microinverter’s recommended module power range.
SolarEdge and other optimizer-based systems size strings by the optimizer rules — use the manufacturer’s designer. Reference inverters: most named in SoCal permits since Oct 2024.

Expected production in Southern California

NLR PVWatts v8 · Cali-Graf calculation
CitykWh / kW / yrkWh / panel / yrkWh / system / yrSun, kWh/m²/day
Los Angeles1,67680412,0676.08
Palmdale1,83588113,2126.69
Chula Vista1,69681412,2116.11
Huntington Beach1,64378911,8305.89
Riverside1,69681412,2116.21
Santa Clarita1,72482812,4136.28
788Jan788Feb1,012Mar1,117Apr1,104May1,173Jun1,236Jul1,250Aug1,093Sep964Oct829Nov717DeckWh per month · Los Angeles
Estimate for comparison, not a quote: shading, roof orientation and local losses change real output. Roof mount, 20° tilt, south, 14% system losses.

Compare with similar 480 W panels

CEC PV Module List (Oct 7, 2026) · Kiwa PVEL Scorecard · datasheets · building permits
PanelPmaxEfficiencyγ Pmax (CEC)Voc, VIsc, APVEL (product / brand)SoCal permits (series)
URE (United Renewable Energy) FAK480CAG480 W≈20.1%−0.34753.111.42——
REC Group REC475AA Pure-RX475 W≈23.5%−0.24865.79brand 9× (2016–2025)33
SEG Solar SEG-495-BTD-BG495 W≈25.3%−0.29039.915.82product 2023, 2024, 2025, 20268
Qcells Q.PEAK DUO XL-G10.d 480480 W≥20.7%−0.34053.6111.26product 20236
Same fields from the same sources for every row; ≈ efficiency is calculated from the listed area. Comparable series: other brands, same product group, power range covering this class.

Questions & answers

How efficient is the URE (United Renewable Energy) FAK480CAG?

Calculated from the panel area (2.39 m²): about 20.1% for the 480 W class. 480 W over 2.39 m² equals about 201 W per square meter.

How much energy does one panel produce in Los Angeles or Palmdale?

PVWatts v8 with typical-year weather gives about 804 kWh per year per 480 W panel in Los Angeles and about 881 kWh in Palmdale (20° roof, facing south, 14% system losses).

How much power does it lose on a hot roof?

With γ = −0.347 %/°C, at a 77 °C cell temperature (hottest modeled hour in Palmdale) output is about 18% below the STC rating.

How many panels fit on one string?

With the Tesla 1538000-xx-y (max DC 600 V, MPPT from 60 V, datasheet) in Los Angeles the calculator gives 2–10 panels per string (Voc at 2 °C = 56.6 V, Vmp at 74 °C cell = 35.5 V). Final design must follow the inverter manual and NEC 690.7.

Does it work with APsystems (Alt Power System) DS3-L microinverters?

Voltage check against the APsystems (Alt Power System) datasheet: Voc when cold 56.6 V vs max input 60 V; Vmp when hot 35.5 V vs MPPT low 28 V; recommended module power 265–570 W. Confirm on the microinverter maker’s compatibility list.

Is it bifacial?

Yes. Rear gain depends on mounting height and ground reflectance.

Sources

  1. California Energy Commission — Solar Equipment Lists, PV Module List, Inverter List (snapshot Oct 7, 2026).
  2. SEG Solar — manufacturer datasheet “XXXTFHTPMBSDPN YUKON/Series )BMG$FMM/5ZQF501$PO”.
  3. Qcells — manufacturer datasheet “Q.PEAK DUO XL-G10.d ENDURING HIGH PERFORMANCE”.
  4. Kiwa PVEL — PV Module Reliability Scorecard, Top Performer lists.
  5. NLR (formerly NREL) — System Advisor Model CEC module and inverter libraries (version 2026.7.3).
  6. NLR (formerly NREL) — PVWatts v8, NSRDB PSM v3 typical-year weather for Los Angeles, Palmdale, Chula Vista, Huntington Beach, Riverside, Santa Clarita.
  7. Inverter datasheets — APsystems (Alt Power System), Enphase, Solis (Ginlong), Tesla (manufacturer documents).
  8. Building permits — Southern California permit portals. Equipment matched from permit descriptions.
  9. Cali-Graf calculations — formulas and inputs are shown next to each calculated value (efficiency from area, temperature-corrected voltages, string sizing, energy estimates).