Solar panelUniversal Solar Americas

Universal Solar Americas UNI450-120M-BB

120 half-cut cells (12 × 10), PERC. Power classes 450–455 W in the CEC list; datasheet covers 445–460 W.

CEC listed · Dec 12, 2022UL 61730PERC
Power class
  • Power (STC)450 WCEC nameplate
  • Efficiency≥21.0%datasheet minimum
  • %/°C Pmax−0.389CEC listing test
  • Performance warranty30 yrdatasheet

Power classes

CEC PV Module List (Oct 7, 2026) · Universal Solar Americas datasheet · 2 models
ModelPmaxVoc, VIsc, AVmp, VImp, AEfficiencyPTCCEC listed
UNI450-120M-BB450 W42.1013.5635.0012.86≥21.0%414 WDec 12, 2022
UNI455-120M-BB455 W42.3013.6335.2012.93≥21.2%419 WDec 12, 2022

Build & dimensions

Universal Solar Americas datasheet · Cali-Graf calculation

Heat & cold behaviour

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation · Universal Solar Americas datasheet
DatasheetCEC listing test
Pmax coefficient γ—−0.389 %/°C
Voc coefficient β—−0.292 %/°C
Isc coefficient α—+0.044 %/°C
Vmp coefficient≈ −0.43 %/°C—
Operating cell temperatureNMOT 45 °CNOCT 46.6 °C
Vmp coefficient ≈ γ − α (CEC); used only for the hot-roof voltage estimate.

At normal operating conditions (NOCT, 800 W/m²) — datasheet

ClassPmax, WVoc, VIsc, AVmp, VImp, A
450 W332.139.4010.9532.7010.17
455 W335.839.5011.0132.8010.23

Away from lab conditions — CEC listing test points

ClassPmax at NOCTVmp × Imp at NOCTPmax at 200 W/m²Low-light efficiency vs STC
450 W334.4 W32.3 V × 10.35 A90.1 W100%
455 W338.2 W32.49 V × 10.41 A91.1 W100%
Pmax = Vmp × Imp from the CEC listing; low-light efficiency = Pmax at 200 W/m² ÷ (20% of STC Pmax).

Electrical & strength ratings

Warranty & degradation

Universal Solar Americas datasheet

Inverter compatibility & string sizing

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation · NLR PVWatts v8 · inverter datasheets · NLR SAM inverter library · CEC Grid Support Inverter List (Oct 7, 2026)
44.9 V
Voc when cold
per panel
27.6 V
Vmp when hot
per panel
13
Max panels / string
max DC 600 V
3
Min panels / string
MPPT from 60 V
Defaults come from NLR TMY weather (coldest hour, hottest modeled cell). Code calculations (NEC 690.7) use the ASHRAE extreme annual minimum, which is usually colder — enter it above. β is the CEC-measured coefficient; NEC 690.7 calculations use the datasheet value.

String inverters most named in SoCal permits

InverterMax DC inputMPPTWindow sourcePanels per string
Tesla 1538000-xx-y600 V60–480 Vdatasheet3–13
Solis (Ginlong) S6-EH1P10K-H-US600 V80–520 Vdatasheet3–13
Solis (Ginlong) Solis-1P7.6K-4G-US600 V100–500 Vdatasheet4–13
Qcells Q.VOLT H7.6SX498 V234–498 VCEC test window9–11

Microinverters (one per panel)

MicroinverterRecommended module powerMax DC inputMPPTVoc cold / Vmp hotCheckDC/AC
Enphase IQ8X-80-M-US320–540 W79.5 V43–60 V44.9 / 27.6 V✗ Not a match: module voltage below MPPT range1.18
APsystems (Alt Power System) DS3-L265–570 W60 V28–45 V44.9 / 27.6 V⚠ Works; below MPPT at peak heat0.58
Enphase IQ8M-72-2-US260–460 W60 V30–45 V44.9 / 27.6 V⚠ Works; below MPPT at peak heat1.38
Enphase IQ8A-72-2-US295–500 W60 V32–45 V44.9 / 27.6 V⚠ Works; below MPPT at peak heat1.29
Voltage check against the microinverter datasheets — confirm the pairing on the manufacturer’s module compatibility list. Rows appear only when the panel’s power is inside the microinverter’s recommended module power range.
SolarEdge and other optimizer-based systems size strings by the optimizer rules — use the manufacturer’s designer. Reference inverters: most named in SoCal permits since Oct 2024.

Expected production in Southern California

NLR PVWatts v8 · Cali-Graf calculation
CitykWh / kW / yrkWh / panel / yrkWh / system / yrSun, kWh/m²/day
Los Angeles1,67675412,0676.08
Palmdale1,83582613,2126.69
Chula Vista1,69676312,2116.11
Huntington Beach1,64373911,8305.89
Riverside1,69676312,2116.21
Santa Clarita1,72477612,4136.28
788Jan788Feb1,012Mar1,117Apr1,104May1,173Jun1,236Jul1,250Aug1,093Sep964Oct829Nov717DeckWh per month · Los Angeles
Estimate for comparison, not a quote: shading, roof orientation and local losses change real output. Roof mount, 20° tilt, south, 14% system losses.

Compare with similar 450 W panels

CEC PV Module List (Oct 7, 2026) · datasheets · Kiwa PVEL Scorecard · building permits
PanelPmaxEfficiencyγ Pmax (CEC)Voc, VIsc, APVEL (product / brand)SoCal permits (series)
Universal Solar Americas UNI450-120M-BB450 W≥21%−0.38942.113.56——
Qcells Q.TRON BLK M-G2+ 445445 W≈22.8%−0.27640.1613.98brand 11× (2016–2026)40
Hyundai Energy Solutions HiN-T450NF(BK)450 W≈23.2%−0.29839.214.53brand 5× (2017–2025)37
REC Group REC450AA Pure-RX450 W≈22.3%−0.24865.18.81brand 9× (2016–2025)33
Same fields from the same sources for every row; ≈ efficiency is calculated from the listed area. Comparable series: other brands, same product group, power range covering this class.

Questions & answers

How efficient is the Universal Solar Americas UNI450-120M-BB?

The Universal Solar Americas datasheet guarantees at least 21% module efficiency for the 450 W class (up to 21.2% for 455 W). 450 W over 2.17 m² equals about 207 W per square meter.

How much energy does one panel produce in Los Angeles or Palmdale?

PVWatts v8 with typical-year weather gives about 754 kWh per year per 450 W panel in Los Angeles and about 826 kWh in Palmdale (20° roof, facing south, 14% system losses).

How much power does it lose on a hot roof?

With γ = −0.389 %/°C, at a 77 °C cell temperature (hottest modeled hour in Palmdale) output is about 20.2% below the STC rating.

How many panels fit on one string?

With the Tesla 1538000-xx-y (max DC 600 V, MPPT from 60 V, datasheet) in Los Angeles the calculator gives 3–13 panels per string (Voc at 2 °C = 44.9 V, Vmp at 74 °C cell = 27.6 V). Final design must follow the inverter manual and NEC 690.7.

What does the warranty cover?

30 years linear on performance (manufacturer datasheet).

How big and heavy is it?

75.4 × 44.6 × 1.38 in (1,914 × 1,133 × 35 mm), 52.9 lb (24 kg).

Sources

  1. California Energy Commission — Solar Equipment Lists, PV Module List, Inverter List (snapshot Oct 7, 2026).
  2. Universal Solar Americas — manufacturer datasheet “UNI-450-120M-BB Highest power output Module Efficiency”.
  3. Qcells — manufacturer datasheet “Q.TRON BLK M-G2+ SERIES 415–440 Wp”.
  4. Hyundai Energy Solutions — datasheet [US] NF(BK)(HiN) Series (N TOPCon Bifacial) 435~445W.
  5. Kiwa PVEL — PV Module Reliability Scorecard, Top Performer lists.
  6. NLR (formerly NREL) — System Advisor Model CEC inverter library (version 2026.7.3).
  7. NLR (formerly NREL) — PVWatts v8, NSRDB PSM v3 typical-year weather for Los Angeles, Palmdale, Chula Vista, Huntington Beach, Riverside, Santa Clarita.
  8. Inverter datasheets — APsystems (Alt Power System), Enphase, Solis (Ginlong), Tesla (manufacturer documents).
  9. Building permits — Southern California permit portals. Equipment matched from permit descriptions.
  10. Cali-Graf calculations — formulas and inputs are shown next to each calculated value (efficiency from area, temperature-corrected voltages, string sizing, energy estimates).