Details describe the tested sample, not every module of the series.
RETC PV Module Index — Trina Solar
Year
Recognition
2023
Overall Highest Achiever; High Achievement in Performance (Ptc-to-stc ratio, Module efficiency, LeTID RESISTANCE); High Achievement in Quality (Hail durability test); High Achievement in Reliability (Thermal cycle test, SDML, Pid resistance, Damp heat test)
2024
Overall Highest Achiever
2025
Overall Highest Achiever
2026
Overall Highest Achiever; High achievement in performance; High achievement in reliability; Performance discipline high achiever (Temperature coefficient, Iam, Letid, PAN file); Quality discipline high achiever (BOM verification); Reliability discipline high achiever (Damp heat, Pid, Sdml, Tc)
Inverter compatibility & string sizing
CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation · NLR PVWatts v8 · inverter datasheets · NLR SAM inverter library · CEC Grid Support Inverter List (Oct 7, 2026)
37.4 V
Voc when cold
per panel
24.5 V
Vmp when hot
per panel
16
Max panels / string
max DC 600 V
3
Min panels / string
MPPT from 60 V
Defaults come from NLR TMY weather (coldest hour, hottest modeled cell). Code calculations (NEC 690.7) use the ASHRAE extreme annual minimum, which is usually colder — enter it above. β is the CEC-measured coefficient; NEC 690.7 calculations use the datasheet value.
String inverters most named in SoCal permits
Inverter
Max DC input
MPPT
Window source
Panels per string
Tesla 1538000-xx-y
600 V
60–480 V
datasheet
3–16
Solis (Ginlong) S6-EH1P10K-H-US
600 V
80–520 V
datasheet
4–16
Solis (Ginlong) Solis-1P7.6K-4G-US
600 V
100–500 V
datasheet
5–16
Qcells Q.VOLT H7.6SX
498 V
234–498 V
CEC test window
10–13
Microinverters (one per panel)
Microinverter
Recommended module power
Max DC input
MPPT
Voc cold / Vmp hot
Check
DC/AC
Enphase IQ8PLUS-72-2-US
235–440 W
60 V
29–45 V
37.4 / 24.5 V
⚠ Works; below MPPT at peak heat
1.5
Enphase IQ8X-80-M-US
320–540 W
79.5 V
43–60 V
37.4 / 24.5 V
✗ Not a match: module voltage below MPPT range
1.14
APsystems (Alt Power System) DS3-L
265–570 W
60 V
28–45 V
37.4 / 24.5 V
⚠ Works; below MPPT at peak heat
0.56
Enphase IQ8M-72-2-US
260–460 W
60 V
30–45 V
37.4 / 24.5 V
✗ Not a match: module voltage below MPPT range
1.34
Enphase IQ8A-72-2-US
295–500 W
60 V
32–45 V
37.4 / 24.5 V
✗ Not a match: module voltage below MPPT range
1.25
Voltage check against the microinverter datasheets — confirm the pairing on the manufacturer’s module compatibility list. Rows appear only when the panel’s power is inside the microinverter’s recommended module power range.
SolarEdge and other optimizer-based systems size strings by the optimizer rules — use the manufacturer’s designer. Reference inverters: most named in SoCal permits since Oct 2024.
Expected production in Southern California
NLR PVWatts v8 · Cali-Graf calculation
City
kWh / kW / yr
kWh / panel / yr
kWh / system / yr
Sun, kWh/m²/day
Los Angeles
1,676
729
11,665
6.08
Palmdale
1,835
798
12,772
6.69
Chula Vista
1,696
738
11,804
6.11
Huntington Beach
1,643
715
11,435
5.89
Riverside
1,696
738
11,804
6.21
Santa Clarita
1,724
750
11,999
6.28
Estimate for comparison, not a quote: shading, roof orientation and local losses change real output. Roof mount, 20° tilt, south, 14% system losses.
Compare with similar 435 W panels
CEC PV Module List (Oct 7, 2026) · datasheets · Kiwa PVEL Scorecard · building permits
Panel
Pmax
Efficiency
γ Pmax (CEC)
Voc, V
Isc, A
Warranty
PVEL (product / brand)
SoCal permits (series)
Trina Solar TSM-435NEG9RH.25
435 W
≈22%
−0.291
35.3
15.76
—
product 2026
—
Canadian Solar CS3N-430MS
430 W
≈21.8%
−0.332
45.7
11.86
25 yr
product 2023
46
Qcells Q.TRON BLK M-G2+ 435
435 W
≥22.3%
−0.276
39.6
13.82
25 / 25 yr
brand 11× (2016–2026)
40
Silfab Solar SIL-435QD
435 W
≈22.3%
−0.294
38.94
14.05
25 / 30 yr
brand 7× (2017–2025)
39
Same fields from the same sources for every row; ≈ efficiency is calculated from the listed area. Comparable series: other brands, same product group, power range covering this class.
About Trina Solar
CEC PV Module List (Oct 7, 2026) · Kiwa PVEL Scorecard · RETC PV Module Index · building permits
How efficient is the Trina Solar TSM-435NEG9RH.25?
Calculated from the panel area (1.98 m²): about 22% for the 435 W class. 435 W over 1.98 m² equals about 220 W per square meter.
How much energy does one panel produce in Los Angeles or Palmdale?
PVWatts v8 with typical-year weather gives about 729 kWh per year per 435 W panel in Los Angeles and about 798 kWh in Palmdale (20° roof, facing south, 14% system losses).
How much power does it lose on a hot roof?
With γ = −0.291 %/°C, at a 77 °C cell temperature (hottest modeled hour in Palmdale) output is about 15.1% below the STC rating.
How many panels fit on one string?
With the Tesla 1538000-xx-y (max DC 600 V, MPPT from 60 V, datasheet) in Los Angeles the calculator gives 3–16 panels per string (Voc at 2 °C = 37.4 V, Vmp at 74 °C cell = 24.5 V). Final design must follow the inverter manual and NEC 690.7.
Has this panel been reliability-tested?
TSM-xxxNEG9RH.25 was a PVEL Top Performer in 2026 (LID+LETID).
Sources
California Energy Commission — Solar Equipment Lists, PV Module List, Inverter List (snapshot Oct 7, 2026).
Canadian Solar — manufacturer datasheet “HiKu Mono PERC CS3N-400|405|410|415|420|425MS MORE POWER”.
Qcells — manufacturer datasheet “Q.TRON BLK M-G2+ SERIES 415–440 Wp”.
NLR (formerly NREL) — System Advisor Model CEC inverter library (version 2026.7.3).
NLR (formerly NREL) — PVWatts v8, NSRDB PSM v3 typical-year weather for Los Angeles, Palmdale, Chula Vista, Huntington Beach, Riverside, Santa Clarita.
Inverter datasheets — APsystems (Alt Power System), Enphase, Solis (Ginlong), Tesla (manufacturer documents).
Building permits — Southern California permit portals. Equipment matched from permit descriptions.
Cali-Graf calculations — formulas and inputs are shown next to each calculated value (efficiency from area, temperature-corrected voltages, string sizing, energy estimates).
Get your free estimate
Three fields, and Cali Energy calls back within 30 minutes during business hours.
Thanks!
We got your request and will call back within 30 minutes during business hours.