Cali-GrafCali-Graf
Solar panelTrina Solar

Trina Solar TSM-340DE151M.T8(II)

120 half-cut cells. Power classes 330–355 W in the CEC list.

CEC listed · May 2, 2022UL 61730
Power class
  • Power (STC)340 WCEC nameplate
  • Efficiency≈17.6%calculated from area
  • %/°C Pmax−0.357CEC listing test
  • PTC / STC92.9%PTC 316 W (CEC)

Power classes

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation · 6 models
ModelPmaxVoc, VIsc, AVmp, VImp, AEfficiencyPTCCEC listed
TSM-330DE151M.T8(II)330 W40.6010.3933.809.76≈17.1%306 WMay 2, 2022
TSM-335DE151M.T8(II)335 W40.7010.4834.009.85≈17.4%311 WMay 2, 2022
TSM-340DE151M.T8(II)340 W41.1010.5534.209.94≈17.6%316 WMay 2, 2022
TSM-345DE151M.T8(II)345 W41.2010.5634.5010.00≈17.9%320 WMay 2, 2022
TSM-350DE151M.T8(II)350 W41.2010.6034.6010.10≈18.1%325 WMay 2, 2022
TSM-355DE151M.T8(II)355 W41.6010.7034.8010.20≈18.4%330 WMay 2, 2022
≈ efficiency = Pmax ÷ CEC-listed area 1.93 m².

Build & dimensions

CEC PV Module List (Oct 7, 2026)

Heat & cold behaviour

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation
CEC listing test
Pmax coefficient γ−0.357 %/°C
Voc coefficient β−0.273 %/°C
Isc coefficient α+0.033 %/°C
Operating cell temperatureNOCT 44.9 °C
Vmp coefficient ≈ γ − α (CEC); used only for the hot-roof voltage estimate.

Away from lab conditions — CEC listing test points

ClassPmax at NOCTVmp × Imp at NOCTPmax at 200 W/m²Low-light efficiency vs STC
330 W242.2 W30.68 V × 7.89 A62.9 W95%
335 W245.9 W30.87 V × 7.97 A63.8 W95%
340 W249.6 W31.05 V × 8.04 A64.8 W95%
345 W253.3 W31.32 V × 8.09 A65.8 W95%
350 W256.6 W31.41 V × 8.17 A66.6 W95%
355 W260.6 W31.59 V × 8.25 A67.7 W95%
Pmax = Vmp × Imp from the CEC listing; low-light efficiency = Pmax at 200 W/m² ÷ (20% of STC Pmax).

Certifications

CEC PV Module List (Oct 7, 2026)
UL 61730IEC 61215

Independent reliability testing

Kiwa PVEL Scorecard · RETC PV Module Index
12
PVEL Scorecards
Trina Solar named Top Performer, 2014–2026
2023, 2024, 2025, 2026
RETC Overall Highest Achiever
Trina Solar, manufacturer level
This exact series is not listed in published PVEL Top Performer tables. Results below are for the manufacturer.

RETC PV Module Index — Trina Solar

YearRecognition
2023Overall Highest Achiever; High Achievement in Performance (Ptc-to-stc ratio, Module efficiency, LeTID RESISTANCE); High Achievement in Quality (Hail durability test); High Achievement in Reliability (Thermal cycle test, SDML, Pid resistance, Damp heat test)
2024Overall Highest Achiever
2025Overall Highest Achiever
2026Overall Highest Achiever; High achievement in performance; High achievement in reliability; Performance discipline high achiever (Temperature coefficient, Iam, Letid, PAN file); Quality discipline high achiever (BOM verification); Reliability discipline high achiever (Damp heat, Pid, Sdml, Tc)

Inverter compatibility & string sizing

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation · NLR PVWatts v8 · inverter datasheets · NLR SAM inverter library · CEC Grid Support Inverter List (Oct 7, 2026)
43.7 V
Voc when cold
per panel
27.7 V
Vmp when hot
per panel
13
Max panels / string
max DC 600 V
3
Min panels / string
MPPT from 60 V
Defaults come from NLR TMY weather (coldest hour, hottest modeled cell). Code calculations (NEC 690.7) use the ASHRAE extreme annual minimum, which is usually colder — enter it above. β is the CEC-measured coefficient; NEC 690.7 calculations use the datasheet value.

String inverters most named in SoCal permits

InverterMax DC inputMPPTWindow sourcePanels per string
Tesla 1538000-xx-y600 V60–480 Vdatasheet3–13
Solis (Ginlong) S6-EH1P10K-H-US600 V80–520 Vdatasheet3–13
Solis (Ginlong) Solis-1P7.6K-4G-US600 V100–500 Vdatasheet4–13
Qcells Q.VOLT H7.6SX498 V234–498 VCEC test window9–11

Microinverters (one per panel)

MicroinverterRecommended module powerMax DC inputMPPTVoc cold / Vmp hotCheckDC/AC
Enphase IQ8PLUS-72-2-US235–440 W60 V29–45 V43.7 / 27.7 V⚠ Works; below MPPT at peak heat1.17
Enphase IQ8X-80-M-US320–540 W79.5 V43–60 V43.7 / 27.7 V✗ Not a match: module voltage below MPPT range0.89
APsystems (Alt Power System) DS3-L265–570 W60 V28–45 V43.7 / 27.7 V⚠ Works; below MPPT at peak heat0.44
Enphase IQ8M-72-2-US260–460 W60 V30–45 V43.7 / 27.7 V⚠ Works; below MPPT at peak heat1.05
Enphase IQ8A-72-2-US295–500 W60 V32–45 V43.7 / 27.7 V⚠ Works; below MPPT at peak heat0.97
Voltage check against the microinverter datasheets — confirm the pairing on the manufacturer’s module compatibility list. Rows appear only when the panel’s power is inside the microinverter’s recommended module power range.
SolarEdge and other optimizer-based systems size strings by the optimizer rules — use the manufacturer’s designer. Reference inverters: most named in SoCal permits since Oct 2024.

Expected production in Southern California

NLR PVWatts v8 · Cali-Graf calculation
CitykWh / kW / yrkWh / panel / yrkWh / system / yrSun, kWh/m²/day
Los Angeles1,67657011,9676.08
Palmdale1,83562413,1026.69
Chula Vista1,69657712,1096.11
Huntington Beach1,64355911,7315.89
Riverside1,69657712,1096.21
Santa Clarita1,72458612,3096.28
781Jan782Feb1,003Mar1,108Apr1,095May1,163Jun1,225Jul1,240Aug1,084Sep956Oct822Nov711DeckWh per month · Los Angeles
Estimate for comparison, not a quote: shading, roof orientation and local losses change real output. Roof mount, 20° tilt, south, 14% system losses.

Compare with similar 340 W panels

CEC PV Module List (Oct 7, 2026) · Kiwa PVEL Scorecard · JinkoSolar datasheets · building permits
PanelPmaxEfficiencyγ Pmax (CEC)Voc, VIsc, APVEL (product / brand)SoCal permits (series)
Trina Solar TSM-340DE151M.T8(II)340 W≈17.6%−0.35741.110.55brand 12×—
LONGi LR4-60HPB-340M340 W≈18.8%−0.33740.110.84product 2021, 2022193
JinkoSolar JKM340M-60HBL340 W≈20.1%−0.4064110.82brand 12× (2014–2026)45
REC Group REC340AA340 W≈20.2%−0.27943.110.09brand 9× (2016–2025)30
Same fields from the same sources for every row; ≈ efficiency is calculated from the listed area. Comparable series: other brands, same product group, power range covering this class.

About Trina Solar

CEC PV Module List (Oct 7, 2026) · Kiwa PVEL Scorecard · RETC PV Module Index · building permits

Other series by SoCal permits

TSM-xxxDE06X.05(II) · 23TSM-xxxNE09RC.05 · 6TSM-xxxDE09C.07 · 6TSM-xxxNEG19RC.20TSM-xxxNEG21C.20TSM-xxxNEG9RH.25

Questions & answers

How efficient is the Trina Solar TSM-340DE151M.T8(II)?

Calculated from the panel area (1.93 m²): about 17.6% for the 340 W class. 340 W over 1.93 m² equals about 176 W per square meter.

How much energy does one panel produce in Los Angeles or Palmdale?

PVWatts v8 with typical-year weather gives about 570 kWh per year per 340 W panel in Los Angeles and about 624 kWh in Palmdale (20° roof, facing south, 14% system losses).

How much power does it lose on a hot roof?

With γ = −0.357 %/°C, at a 77 °C cell temperature (hottest modeled hour in Palmdale) output is about 18.5% below the STC rating.

How many panels fit on one string?

With the Tesla 1538000-xx-y (max DC 600 V, MPPT from 60 V, datasheet) in Los Angeles the calculator gives 3–13 panels per string (Voc at 2 °C = 43.7 V, Vmp at 74 °C cell = 27.7 V). Final design must follow the inverter manual and NEC 690.7.

Has this panel been reliability-tested?

This exact series is not in published PVEL Top Performer tables; Trina Solar was named a Top Performer in 12 Scorecards (2014–2026). RETC named Trina Solar Overall Highest Achiever in 2023, 2024, 2025, 2026.

Sources

  1. California Energy Commission — Solar Equipment Lists, PV Module List, Inverter List (snapshot Oct 7, 2026).
  2. JinkoSolar — datasheet THE MOST DEPENDABLE SOLAR BRAND.
  3. JinkoSolar — manufacturer datasheet “Eagle HC 60M G2 315-335 Watt MONO PERC HALF CELL MODULE”.
  4. Kiwa PVEL — PV Module Reliability Scorecard, Top Performer lists 2014–2026.
  5. RETC — PV Module Index reports 2023–2026.
  6. NLR (formerly NREL) — System Advisor Model CEC inverter library (version 2026.7.3).
  7. NLR (formerly NREL) — PVWatts v8, NSRDB PSM v3 typical-year weather for Los Angeles, Palmdale, Chula Vista, Huntington Beach, Riverside, Santa Clarita.
  8. Inverter datasheets — APsystems (Alt Power System), Enphase, Solis (Ginlong), Tesla (manufacturer documents).
  9. Building permits — Southern California permit portals. Equipment matched from permit descriptions.
  10. Cali-Graf calculations — formulas and inputs are shown next to each calculated value (efficiency from area, temperature-corrected voltages, string sizing, energy estimates).