132 half-cut cells, bifacial, glass (dual-glass module). Power classes 595–620 W in the CEC list.
| Model | Pmax | Voc, V | Isc, A | Vmp, V | Imp, A | Efficiency | PTC | CEC listed |
|---|---|---|---|---|---|---|---|---|
| TS-BGT66(595)-G12R | 595 W | 48.10 | 15.76 | 40.00 | 14.89 | ≈22.2% | 565 W | Feb 2, 2026 |
| TS-BGT66(600)-G12R | 600 W | 48.40 | 15.80 | 40.30 | 14.91 | ≈22.4% | 570 W | Feb 2, 2026 |
| TS-BGT66(605)-G12R | 605 W | 48.70 | 15.83 | 40.50 | 14.94 | ≈22.6% | 575 W | Feb 2, 2026 |
| TS-BGT66(610)-G12R | 610 W | 49.00 | 15.86 | 40.80 | 14.96 | ≈22.8% | 580 W | Feb 2, 2026 |
| TS-BGT66(615)-G12R | 615 W | 49.30 | 15.89 | 40.98 | 14.98 | ≈22.9% | 584 W | Feb 2, 2026 |
| TS-BGT66(620)-G12R | 620 W | 49.60 | 15.92 | 41.22 | 15.03 | ≈23.1% | 589 W | Feb 2, 2026 |
| CEC listing test | |
|---|---|
| Pmax coefficient γ | −0.299 %/°C |
| Voc coefficient β | −0.205 %/°C |
| Isc coefficient α | +0.043 %/°C |
| Operating cell temperature | NOCT 43.2 °C |
| Class | Pmax at NOCT | Vmp × Imp at NOCT | Pmax at 200 W/m² | Low-light efficiency vs STC |
|---|---|---|---|---|
| 595 W | 445.7 W | 38.89 V × 11.46 A | 116.5 W | 98% |
| 600 W | 449.6 W | 39.18 V × 11.47 A | 117.5 W | 98% |
| 605 W | 452.8 W | 39.38 V × 11.5 A | 118.3 W | 98% |
| 610 W | 456.7 W | 39.67 V × 11.51 A | 119.4 W | 98% |
| 615 W | 459.4 W | 39.85 V × 11.53 A | 120.1 W | 98% |
| 620 W | 463.6 W | 40.08 V × 11.57 A | 121.2 W | 98% |
| Year | Recognition |
|---|---|
| 2026 | Overall Highest Achiever; High achievement in performance; High achievement in reliability; Performance discipline high achiever (PAN file, Temperature coefficient, Iam, Letid, Lid); Quality discipline high achiever (BOM verification); Reliability discipline high achiever (Pid, Sdml, Tc, Uvid) |
| Inverter | Max DC input | MPPT | Window source | Panels per string |
|---|---|---|---|---|
| Tesla 1538000-xx-y | 600 V | 60–480 V | datasheet | 2–11 |
| Solis (Ginlong) S6-EH1P10K-H-US | 600 V | 80–520 V | datasheet | 3–11 |
| Solis (Ginlong) Solis-1P7.6K-4G-US | 600 V | 100–500 V | datasheet | 3–11 |
| Qcells Q.VOLT H7.6SX | 498 V | 234–498 V | CEC test window | 7–9 |
| City | kWh / kW / yr | kWh / panel / yr | kWh / system / yr | Sun, kWh/m²/day |
|---|---|---|---|---|
| Los Angeles | 1,676 | 1,014 | 12,168 | 6.08 |
| Palmdale | 1,835 | 1,110 | 13,322 | 6.69 |
| Chula Vista | 1,696 | 1,026 | 12,313 | 6.11 |
| Huntington Beach | 1,643 | 994 | 11,928 | 5.89 |
| Riverside | 1,696 | 1,026 | 12,313 | 6.21 |
| Santa Clarita | 1,724 | 1,043 | 12,516 | 6.28 |
| Panel | Pmax | Efficiency | γ Pmax (CEC) | Voc, V | Isc, A | PVEL (product / brand) | SoCal permits (series) |
|---|---|---|---|---|---|---|---|
| Thornova Solar TS-BGT66(605)-G12R | 605 W | ≈22.6% | −0.299 | 48.7 | 15.83 | brand 3× | — |
| Phono Solar PS605M8GFH-24/TNH | 605 W | ≈23.6% | −0.293 | 53.6 | 13.96 | product 2024, 2025 | 1 |
| Qcells Q.PEAK DUO XL-G11S.3/BFG 600 | 600 W | ≈22.1% | −0.348 | 53.66 | 13.8 | product 2024, 2025, 2026 | 1 |
| VSUN (Vietnam Sunergy) VSUN600N-144MH | 600 W | ≈23.3% | −0.309 | 52.9 | 14.03 | brand 6× (2021–2026) | 1 |
Calculated from the panel area (2.68 m²): about 22.6% for the 605 W class. 605 W over 2.68 m² equals about 226 W per square meter.
PVWatts v8 with typical-year weather gives about 1,014 kWh per year per 605 W panel in Los Angeles and about 1,110 kWh in Palmdale (20° roof, facing south, 14% system losses).
With γ = −0.299 %/°C, at a 77 °C cell temperature (hottest modeled hour in Palmdale) output is about 15.5% below the STC rating.
With the Tesla 1538000-xx-y (max DC 600 V, MPPT from 60 V, datasheet) in Los Angeles the calculator gives 2–11 panels per string (Voc at 2 °C = 51 V, Vmp at 74 °C cell = 33.7 V). Final design must follow the inverter manual and NEC 690.7.
Yes. Rear gain depends on mounting height and ground reflectance.
This exact series is not in published PVEL Top Performer tables; Thornova Solar was named a Top Performer in 3 Scorecards (2024–2026). RETC named Thornova Solar Overall Highest Achiever in 2026.