Cali-GrafCali-Graf
Solar panelThornova Solar

Thornova Solar TS-BBT60(495)

120 half-cut cells, bifacial, transparent backsheet. Power classes 480–510 W in the CEC list.

CEC listed · Sep 11, 2025UL 61730BifacialPVEL Top Performer 2026
Power class
  • Power (STC)495 WCEC nameplate
  • Efficiency≈23.1%calculated from area
  • %/°C Pmax−0.294CEC listing test
  • PTC / STC95.1%PTC 471 W (CEC)

Power classes

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation · 7 models
ModelPmaxVoc, VIsc, AVmp, VImp, AEfficiencyPTCCEC listed
TS-BBT60(480)480 W43.1413.5836.9712.98≈22.4%456 WSep 11, 2025
TS-BBT60(485)485 W43.2713.6537.0913.08≈22.7%461 WSep 11, 2025
TS-BBT60(490)490 W43.4213.7437.2013.18≈22.9%466 WSep 11, 2025
TS-BBT60(495)495 W43.5713.8337.3113.28≈23.1%471 WSep 11, 2025
TS-BBT60(500)500 W43.7213.9237.4213.37≈23.4%476 WSep 11, 2025
TS-BBT60(505)505 W43.8714.0137.5213.47≈23.6%481 WSep 11, 2025
TS-BBT60(510)510 W44.0214.0937.6113.57≈23.8%486 WSep 11, 2025
≈ efficiency = Pmax ÷ CEC-listed area 2.14 m².

Build & dimensions

CEC PV Module List (Oct 7, 2026)

Heat & cold behaviour

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation
CEC listing test
Pmax coefficient γ−0.294 %/°C
Voc coefficient β−0.232 %/°C
Isc coefficient α+0.045 %/°C
Operating cell temperatureNOCT 43.2 °C
Vmp coefficient ≈ γ − α (CEC); used only for the hot-roof voltage estimate.

Away from lab conditions — CEC listing test points

ClassPmax at NOCTVmp × Imp at NOCTPmax at 200 W/m²Low-light efficiency vs STC
480 W361.9 W35.41 V × 10.22 A92.6 W96%
485 W365.9 W35.53 V × 10.3 A93.6 W96%
490 W369.8 W35.63 V × 10.38 A94.6 W97%
495 W373.7 W35.74 V × 10.46 A95.6 W97%
500 W377.3 W35.84 V × 10.53 A96.5 W97%
505 W381.2 W35.94 V × 10.61 A97.5 W97%
510 W384.9 W36.02 V × 10.69 A98.5 W97%
Pmax = Vmp × Imp from the CEC listing; low-light efficiency = Pmax at 200 W/m² ÷ (20% of STC Pmax).

Independent reliability testing

Kiwa PVEL Scorecard · RETC PV Module Index
2026
PVEL Top Performer
this series
2
Tests passed as Top Performer
LID+LETID, UVID
3
PVEL Scorecards
Thornova Solar named Top Performer, 2024–2026
2026
RETC Overall Highest Achiever
Thornova Solar, manufacturer level

PVEL Top Performer tests

YearProductTests
2026TS-BBT60(xxx)LID+LETIDUVID

Tested bill of materials

Details describe the tested sample, not every module of the series.

RETC PV Module Index — Thornova Solar

YearRecognition
2026Overall Highest Achiever; High achievement in performance; High achievement in reliability; Performance discipline high achiever (PAN file, Temperature coefficient, Iam, Letid, Lid); Quality discipline high achiever (BOM verification); Reliability discipline high achiever (Pid, Sdml, Tc, Uvid)

Inverter compatibility & string sizing

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation · NLR PVWatts v8 · inverter datasheets · NLR SAM inverter library · CEC Grid Support Inverter List (Oct 7, 2026)
45.9 V
Voc when cold
per panel
31.1 V
Vmp when hot
per panel
13
Max panels / string
max DC 600 V
2
Min panels / string
MPPT from 60 V
Defaults come from NLR TMY weather (coldest hour, hottest modeled cell). Code calculations (NEC 690.7) use the ASHRAE extreme annual minimum, which is usually colder — enter it above. β is the CEC-measured coefficient; NEC 690.7 calculations use the datasheet value.

String inverters most named in SoCal permits

InverterMax DC inputMPPTWindow sourcePanels per string
Tesla 1538000-xx-y600 V60–480 Vdatasheet2–13
Solis (Ginlong) S6-EH1P10K-H-US600 V80–520 Vdatasheet3–13
Solis (Ginlong) Solis-1P7.6K-4G-US600 V100–500 Vdatasheet4–13
Qcells Q.VOLT H7.6SX498 V234–498 VCEC test window8–10

Microinverters (one per panel)

MicroinverterRecommended module powerMax DC inputMPPTVoc cold / Vmp hotCheckDC/AC
Enphase IQ8X-80-M-US320–540 W79.5 V43–60 V45.9 / 31.1 V✗ Not a match: module voltage below MPPT range1.3
APsystems (Alt Power System) DS3-L265–570 W60 V28–45 V45.9 / 31.1 V✓ Within range0.63
Enphase IQ8A-72-2-US295–500 W60 V32–45 V45.9 / 31.1 V⚠ Works; below MPPT at peak heat1.42
Voltage check against the microinverter datasheets — confirm the pairing on the manufacturer’s module compatibility list. Rows appear only when the panel’s power is inside the microinverter’s recommended module power range.
SolarEdge and other optimizer-based systems size strings by the optimizer rules — use the manufacturer’s designer. Reference inverters: most named in SoCal permits since Oct 2024.

Expected production in Southern California

NLR PVWatts v8 · Cali-Graf calculation
CitykWh / kW / yrkWh / panel / yrkWh / system / yrSun, kWh/m²/day
Los Angeles1,67683011,6156.08
Palmdale1,83590812,7176.69
Chula Vista1,69684011,7536.11
Huntington Beach1,64381311,3865.89
Riverside1,69684011,7536.21
Santa Clarita1,72485311,9476.28
758Jan759Feb974Mar1,076Apr1,062May1,129Jun1,189Jul1,203Aug1,052Sep928Oct798Nov690DeckWh per month · Los Angeles
Estimate for comparison, not a quote: shading, roof orientation and local losses change real output. Roof mount, 20° tilt, south, 14% system losses.

Compare with similar 495 W panels

CEC PV Module List (Oct 7, 2026) · datasheets · Kiwa PVEL Scorecard · building permits
PanelPmaxEfficiencyγ Pmax (CEC)Voc, VIsc, APVEL (product / brand)SoCal permits (series)
Thornova Solar TS-BBT60(495)495 W≈23.1%−0.29443.5713.83product 2026—
SEG Solar SEG-495-BTD-BG495 W≈25.3%−0.29039.915.82product 2023, 2024, 2025, 20268
Qcells Q.PEAK DUO XL-G10.d 495495 W≥21.4%−0.34053.7111.34product 20236
AXITEC AC-530MH/144V530 W≥20.5%−0.36649.313.72—1
Same fields from the same sources for every row; ≈ efficiency is calculated from the listed area. Comparable series: other brands, same product group, power range covering this class.

About Thornova Solar

CEC PV Module List (Oct 7, 2026) · Kiwa PVEL Scorecard · RETC PV Module Index

Other series by SoCal permits

TS-BBT54(xxx)-G12RTS-BGT48(xxx)-G12RTS-BGT54(xxx)-G12RTS-BGT66(xxx)-G12RTS-BB54(xxx)TS-BB60(xxx)

Questions & answers

How efficient is the Thornova Solar TS-BBT60(495)?

Calculated from the panel area (2.14 m²): about 23.1% for the 495 W class. 495 W over 2.14 m² equals about 231 W per square meter.

How much energy does one panel produce in Los Angeles or Palmdale?

PVWatts v8 with typical-year weather gives about 830 kWh per year per 495 W panel in Los Angeles and about 908 kWh in Palmdale (20° roof, facing south, 14% system losses).

How much power does it lose on a hot roof?

With γ = −0.294 %/°C, at a 77 °C cell temperature (hottest modeled hour in Palmdale) output is about 15.2% below the STC rating.

How many panels fit on one string?

With the Tesla 1538000-xx-y (max DC 600 V, MPPT from 60 V, datasheet) in Los Angeles the calculator gives 2–13 panels per string (Voc at 2 °C = 45.9 V, Vmp at 74 °C cell = 31.1 V). Final design must follow the inverter manual and NEC 690.7.

Does it work with APsystems (Alt Power System) DS3-L microinverters?

Voltage check against the APsystems (Alt Power System) datasheet: Voc when cold 45.9 V vs max input 60 V; Vmp when hot 31.1 V vs MPPT low 28 V; recommended module power 265–570 W. Confirm on the microinverter maker’s compatibility list.

Is it bifacial?

Yes. Rear gain depends on mounting height and ground reflectance.

Has this panel been reliability-tested?

TS-BBT60(xxx) was a PVEL Top Performer in 2026 (LID+LETID, UVID).

Sources

  1. California Energy Commission — Solar Equipment Lists, PV Module List, Inverter List (snapshot Oct 7, 2026).
  2. SEG Solar — manufacturer datasheet “XXXTFHTPMBSDPN YUKON/Series )BMG$FMM/5ZQF501$PO”.
  3. Qcells — manufacturer datasheet “Q.PEAK DUO XL-G10.d ENDURING HIGH PERFORMANCE”.
  4. AXITEC — datasheet AXIworldbipremium bifacial 144 cells asemmbled in US.
  5. Kiwa PVEL — PV Module Reliability Scorecard, Top Performer lists 2024–2026.
  6. RETC — PV Module Index report.
  7. NLR (formerly NREL) — System Advisor Model CEC module and inverter libraries (version 2026.7.3).
  8. NLR (formerly NREL) — PVWatts v8, NSRDB PSM v3 typical-year weather for Los Angeles, Palmdale, Chula Vista, Huntington Beach, Riverside, Santa Clarita.
  9. Inverter datasheets — APsystems (Alt Power System), Enphase, Solis (Ginlong), Tesla (manufacturer documents).
  10. Building permits — Southern California permit portals. Equipment matched from permit descriptions.
  11. Cali-Graf calculations — formulas and inputs are shown next to each calculated value (efficiency from area, temperature-corrected voltages, string sizing, energy estimates).