132 half-cut cells. Power classes 395–410 W in the CEC list; datasheet covers 395–405 W.

CEC listed · Dec 21, 2021UL 61730Installed in 10 SoCal permits
Power class
  • Power (STC)395 Wtolerance +5 / −0 W
  • Efficiency≥20.1%datasheet minimum
  • %/°C Pmax−0.34CEC test: −0.362
  • Degradation / yr0.5%after year 1 (warranty)

Power classes

CEC PV Module List (Oct 7, 2026) · Tesla datasheet · Cali-Graf calculation · 4 models
ModelPmaxVoc, VIsc, AVmp, VImp, AEfficiencyPTCCEC listed
T395H395 W45.2711.1036.8810.71≥20.1%367 WDec 21, 2021
T400H400 W45.3011.1437.1310.77≥20.4%372 WDec 21, 2021
T405H405 W45.3411.1737.3910.83≥20.6%376 WDec 21, 2021
T410H410 W45.3711.2037.6410.89≈21.4%381 WDec 21, 2021
≈ efficiency = Pmax ÷ CEC-listed area 1.92 m² for classes outside the datasheet.

Build & dimensions

CEC PV Module List (Oct 7, 2026) · Tesla datasheet

Heat & cold behaviour

Tesla datasheet · CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation
DatasheetCEC listing test
Pmax coefficient γ−0.34 %/°C−0.362 %/°C
Voc coefficient β−0.27 %/°C−0.270 %/°C
Isc coefficient α+0.04 %/°C+0.041 %/°C
Vmp coefficient≈ −0.38 %/°C—
Operating cell temperatureNMOT 45.7 °CNOCT 45.7 °C
Vmp coefficient ≈ γ − α (datasheet); used only for the hot-roof voltage estimate.

At normal operating conditions (NMOT, 800 W/m²) — datasheet

ClassPmax, WVoc, VIsc, AVmp, VImp, A
395 W296.342.698.9535.038.46
400 W300.142.728.9735.258.51
405 W303.842.769.0035.468.57

Away from lab conditions — CEC listing test points

ClassPmax at NOCTVmp × Imp at NOCTPmax at 200 W/m²Low-light efficiency vs STC
395 W291.8 W34.96 V × 8.35 A76.1 W96%
400 W295.4 W35.19 V × 8.39 A77 W96%
405 W299.1 W35.44 V × 8.44 A78 W96%
410 W302.8 W35.68 V × 8.49 A79 W96%
Pmax = Vmp × Imp from the CEC listing; low-light efficiency = Pmax at 200 W/m² ÷ (20% of STC Pmax).

Electrical & strength ratings

Certifications

CEC PV Module List (Oct 7, 2026) · Tesla datasheet
UL 61730IEC 61215Fire rating Type 2 (UL 61730)

Warranty & degradation

Tesla datasheet · Cali-Graf calculation
80%85%90%95%100%051015202598% yr 193.5% yr 1086% yr 25years
  • Year 1≥ 98%
  • Then≤ 0.5% / year
  • Year 10≥ 93.5%calculated from warranty terms
  • Year 25≥ 86%

Inverter compatibility & string sizing

Tesla datasheet · Cali-Graf calculation · NLR PVWatts v8 · CEC PV Module List (Oct 7, 2026) · inverter datasheets · NLR SAM inverter library · CEC Grid Support Inverter List (Oct 7, 2026)
48.1 V
Voc when cold
per panel
30 V
Vmp when hot
per panel
12
Max panels / string
max DC 600 V
2
Min panels / string
MPPT from 60 V
Defaults come from NLR TMY weather (coldest hour, hottest modeled cell). Code calculations (NEC 690.7) use the ASHRAE extreme annual minimum, which is usually colder — enter it above.

String inverters most named in SoCal permits

InverterMax DC inputMPPTWindow sourcePanels per string
Tesla 1538000-xx-y600 V60–480 Vdatasheet2–12
Solis (Ginlong) S6-EH1P10K-H-US600 V80–520 Vdatasheet3–12
Solis (Ginlong) Solis-1P7.6K-4G-US600 V100–500 Vdatasheet4–12
Qcells Q.VOLT H7.6SX498 V234–498 VCEC test window8–10

Microinverters (one per panel)

MicroinverterRecommended module powerMax DC inputMPPTVoc cold / Vmp hotCheckDC/AC
Enphase IQ8PLUS-72-2-US235–440 W60 V29–45 V48.1 / 30 V✓ Within range1.36
Enphase IQ8X-80-M-US320–540 W79.5 V43–60 V48.1 / 30 V✗ Not a match: module voltage below MPPT range1.04
APsystems (Alt Power System) DS3-L265–570 W60 V28–45 V48.1 / 30 V✓ Within range0.51
Enphase IQ8M-72-2-US260–460 W60 V30–45 V48.1 / 30 V✓ Within range1.22
Enphase IQ8A-72-2-US295–500 W60 V32–45 V48.1 / 30 V⚠ Works; below MPPT at peak heat1.13
Voltage check against the microinverter datasheets — confirm the pairing on the manufacturer’s module compatibility list. Rows appear only when the panel’s power is inside the microinverter’s recommended module power range.
SolarEdge and other optimizer-based systems size strings by the optimizer rules — use the manufacturer’s designer. Reference inverters: most named in SoCal permits since Oct 2024.

Expected production in Southern California

NLR PVWatts v8 · Cali-Graf calculation
CitykWh / kW / yrkWh / panel / yrkWh / system / yrSun, kWh/m²/day
Los Angeles1,67666211,9166.08
Palmdale1,83572513,0476.69
Chula Vista1,69667012,0596.11
Huntington Beach1,64364911,6825.89
Riverside1,69667012,0596.21
Santa Clarita1,72468112,2586.28
778Jan779Feb999Mar1,103Apr1,090May1,158Jun1,220Jul1,234Aug1,079Sep952Oct818Nov708DeckWh per month · Los Angeles
Estimate for comparison, not a quote: shading, roof orientation and local losses change real output. Roof mount, 20° tilt, south, 14% system losses.

Who installs TxxxH panels in SoCal

building permits
10
Permits naming this series
Oct 2021 – Sep 2022
1
Jurisdictions so far
LA County (unincorp.) (10)

Permits over time

1Oct ’210Nov0Dec1Jan ’221Feb2Mar1Apr1May0Jun0Jul2Aug1Seppermits per month

Power class named in permit

395 W
5
400 W
5

Typical system

median 8.3 kW, 21 panels (n = 10)

Only installer and ZIP level is shown — no homeowner names, street addresses or permit numbers. Permits from LA County (unincorp.) come without a contractor license, so they count toward totals but not toward installers. Counts grow as more permit portals are loaded.

Installed together with

building permits

Inverters

SolarEdge SE…H (HD-Wave)
6

Optimizers

SolarEdge Power Optimizer
5
Number of permits naming both this panel series and the product; 9 of 10 permits list other equipment.

Compare with similar 395 W panels

CEC PV Module List (Oct 7, 2026) · Qcells datasheet · Kiwa PVEL Scorecard · building permits
PanelPmaxEfficiencyγ Pmax (CEC)Voc, VIsc, APVEL (product / brand)SoCal permits (series)
Tesla T395H395 W≥20.1%−0.36245.2711.1—10
Qcells Q.PEAK DUO BLK ML-G10+ 395395 W≥20.1%−0.36245.2711.1product 2022, 2023221
JA Solar JAM54S31-395/MR395 W≈20.8%−0.32936.9813.7product 2023, 2024152
REC Group REC395AA Pure395 W≈22%−0.25648.710.2brand 9× (2016–2025)66
Same fields from the same sources for every row; ≈ efficiency is calculated from the listed area. Comparable series: other brands, same product group, power range covering this class.

Questions & answers

How efficient is the Tesla T395H?

The Tesla datasheet guarantees at least 20.1% module efficiency for the 395 W class (up to 20.6% for 405 W). 395 W over 1.92 m² equals about 206 W per square meter.

How much energy does one panel produce in Los Angeles or Palmdale?

PVWatts v8 with typical-year weather gives about 662 kWh per year per 395 W panel in Los Angeles and about 725 kWh in Palmdale (20° roof, facing south, 14% system losses).

How much power does it lose on a hot roof?

With γ = −0.34 %/°C, at a 77 °C cell temperature (hottest modeled hour in Palmdale) output is about 17.6% below the STC rating.

How many panels fit on one string?

With the Tesla 1538000-xx-y (max DC 600 V, MPPT from 60 V, datasheet) in Los Angeles the calculator gives 2–12 panels per string (Voc at 2 °C = 48.1 V, Vmp at 74 °C cell = 30 V). Final design must follow the inverter manual and NEC 690.7.

Does it work with Enphase IQ8PLUS-72-2-US microinverters?

Voltage check against the Enphase datasheet: Voc when cold 48.1 V vs max input 60 V; Vmp when hot 30 V vs MPPT low 29 V; recommended module power 235–440 W. Confirm on the microinverter maker’s compatibility list.

What fire rating does it have?

UL 61730 fire rating Type 2 per datasheet.

Sources

  1. California Energy Commission — Solar Equipment Lists, PV Module List, Inverter List (snapshot Oct 7, 2026).
  2. Tesla — manufacturer datasheet “Tesla Photovoltaic Module T395H, T400H, and T405H”.
  3. Qcells — manufacturer datasheet “Q.PEAK DUO BLK ML-G10+ ENDURING HIGH PERFORMANCE”.
  4. Kiwa PVEL — PV Module Reliability Scorecard, Top Performer lists.
  5. NLR (formerly NREL) — System Advisor Model CEC inverter library (version 2026.7.3).
  6. NLR (formerly NREL) — PVWatts v8, NSRDB PSM v3 typical-year weather for Los Angeles, Palmdale, Chula Vista, Huntington Beach, Riverside, Santa Clarita.
  7. Inverter datasheets — APsystems (Alt Power System), Enphase, Solis (Ginlong), Tesla (manufacturer documents).
  8. Building permits — Los Angeles County Public Works (EPIC-LA, unincorporated areas) (Oct 2021 – Sep 2022). Equipment matched from permit descriptions by model number.
  9. Cali-Graf calculations — formulas and inputs are shown next to each calculated value (efficiency from area, temperature-corrected voltages, string sizing, energy estimates).