132 half-cut cells. Power classes 395–410 W in the CEC list; datasheet covers 395–405 W.
CEC listed · Dec 21, 2021UL 61730Installed in 10 SoCal permits
Power class
Power (STC)395 Wtolerance +5 / −0 W
Efficiency≥20.1%datasheet minimum
%/°C Pmax−0.34CEC test: −0.362
Degradation / yr0.5%after year 1 (warranty)
Power classes
CEC PV Module List (Oct 7, 2026) · Tesla datasheet · Cali-Graf calculation · 4 models
Model
Pmax
Voc, V
Isc, A
Vmp, V
Imp, A
Efficiency
PTC
CEC listed
T395H
395 W
45.27
11.10
36.88
10.71
≥20.1%
367 W
Dec 21, 2021
T400H
400 W
45.30
11.14
37.13
10.77
≥20.4%
372 W
Dec 21, 2021
T405H
405 W
45.34
11.17
37.39
10.83
≥20.6%
376 W
Dec 21, 2021
T410H
410 W
45.37
11.20
37.64
10.89
≈21.4%
381 W
Dec 21, 2021
≈ efficiency = Pmax ÷ CEC-listed area 1.92 m² for classes outside the datasheet.
Build & dimensions
CEC PV Module List (Oct 7, 2026) · Tesla datasheet
Module area1.92 m² (20.7 ft²)CEC-listed area
Weight51.8 lb (23.5 kg)
Cells132 half-cut cells
Front glass0.13 in (3.2 mm) thermally pre-stressed glass
Back coverBlack backsheet
FrameBlack Anodized Aluminum Alloy
Junction boxIP68, 3 diodes
Cable / connector4 mm2 | 12 AWG, 1200 mm | 47.2 in. Length · Staubli MC4 or MC4 compatible
Heat & cold behaviour
Tesla datasheet · CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation
Datasheet
CEC listing test
Pmax coefficient γ
−0.34 %/°C
−0.362 %/°C
Voc coefficient β
−0.27 %/°C
−0.270 %/°C
Isc coefficient α
+0.04 %/°C
+0.041 %/°C
Vmp coefficient
≈ −0.38 %/°C
—
Operating cell temperature
NMOT 45.7 °C
NOCT 45.7 °C
Vmp coefficient ≈ γ − α (datasheet); used only for the hot-roof voltage estimate.
At normal operating conditions (NMOT, 800 W/m²) — datasheet
Class
Pmax, W
Voc, V
Isc, A
Vmp, V
Imp, A
395 W
296.3
42.69
8.95
35.03
8.46
400 W
300.1
42.72
8.97
35.25
8.51
405 W
303.8
42.76
9.00
35.46
8.57
Away from lab conditions — CEC listing test points
Class
Pmax at NOCT
Vmp × Imp at NOCT
Pmax at 200 W/m²
Low-light efficiency vs STC
395 W
291.8 W
34.96 V × 8.35 A
76.1 W
96%
400 W
295.4 W
35.19 V × 8.39 A
77 W
96%
405 W
299.1 W
35.44 V × 8.44 A
78 W
96%
410 W
302.8 W
35.68 V × 8.49 A
79 W
96%
Pmax = Vmp × Imp from the CEC listing; low-light efficiency = Pmax at 200 W/m² ÷ (20% of STC Pmax).
Electrical & strength ratings
Max system voltage1,000 V
Max series fuse20 A
Fire rating (UL 61730)Type 2
Module temperature−40 °F to +185 °F−40 °C to +85 °C
Hail25 mm (0.98 in) at 23 km/h
Power tolerance+5 / −0 W
Certifications
CEC PV Module List (Oct 7, 2026) · Tesla datasheet
UL 61730IEC 61215Fire rating Type 2 (UL 61730)
UL 61730CEC listing
IEC 61215datasheet
Fire rating Type 2 (UL 61730)datasheet
Warranty & degradation
Tesla datasheet · Cali-Graf calculation
Year 1≥ 98%
Then≤ 0.5% / year
Year 10≥ 93.5%calculated from warranty terms
Year 25≥ 86%
Inverter compatibility & string sizing
Tesla datasheet · Cali-Graf calculation · NLR PVWatts v8 · CEC PV Module List (Oct 7, 2026) · inverter datasheets · NLR SAM inverter library · CEC Grid Support Inverter List (Oct 7, 2026)
48.1 V
Voc when cold
per panel
30 V
Vmp when hot
per panel
12
Max panels / string
max DC 600 V
2
Min panels / string
MPPT from 60 V
Defaults come from NLR TMY weather (coldest hour, hottest modeled cell). Code calculations (NEC 690.7) use the ASHRAE extreme annual minimum, which is usually colder — enter it above.
String inverters most named in SoCal permits
Inverter
Max DC input
MPPT
Window source
Panels per string
Tesla 1538000-xx-y
600 V
60–480 V
datasheet
2–12
Solis (Ginlong) S6-EH1P10K-H-US
600 V
80–520 V
datasheet
3–12
Solis (Ginlong) Solis-1P7.6K-4G-US
600 V
100–500 V
datasheet
4–12
Qcells Q.VOLT H7.6SX
498 V
234–498 V
CEC test window
8–10
Microinverters (one per panel)
Microinverter
Recommended module power
Max DC input
MPPT
Voc cold / Vmp hot
Check
DC/AC
Enphase IQ8PLUS-72-2-US
235–440 W
60 V
29–45 V
48.1 / 30 V
✓ Within range
1.36
Enphase IQ8X-80-M-US
320–540 W
79.5 V
43–60 V
48.1 / 30 V
✗ Not a match: module voltage below MPPT range
1.04
APsystems (Alt Power System) DS3-L
265–570 W
60 V
28–45 V
48.1 / 30 V
✓ Within range
0.51
Enphase IQ8M-72-2-US
260–460 W
60 V
30–45 V
48.1 / 30 V
✓ Within range
1.22
Enphase IQ8A-72-2-US
295–500 W
60 V
32–45 V
48.1 / 30 V
⚠ Works; below MPPT at peak heat
1.13
Voltage check against the microinverter datasheets — confirm the pairing on the manufacturer’s module compatibility list. Rows appear only when the panel’s power is inside the microinverter’s recommended module power range.
SolarEdge and other optimizer-based systems size strings by the optimizer rules — use the manufacturer’s designer. Reference inverters: most named in SoCal permits since Oct 2024.
Expected production in Southern California
NLR PVWatts v8 · Cali-Graf calculation
City
kWh / kW / yr
kWh / panel / yr
kWh / system / yr
Sun, kWh/m²/day
Los Angeles
1,676
662
11,916
6.08
Palmdale
1,835
725
13,047
6.69
Chula Vista
1,696
670
12,059
6.11
Huntington Beach
1,643
649
11,682
5.89
Riverside
1,696
670
12,059
6.21
Santa Clarita
1,724
681
12,258
6.28
Estimate for comparison, not a quote: shading, roof orientation and local losses change real output. Roof mount, 20° tilt, south, 14% system losses.
Who installs TxxxH panels in SoCal
building permits
10
Permits naming this series
Oct 2021 – Sep 2022
1
Jurisdictions so far
LA County (unincorp.) (10)
Permits over time
Power class named in permit
395 W
5
400 W
5
Typical system
median 8.3 kW, 21 panels (n = 10)
Only installer and ZIP level is shown — no homeowner names, street addresses or permit numbers. Permits from LA County (unincorp.) come without a contractor license, so they count toward totals but not toward installers. Counts grow as more permit portals are loaded.
Installed together with
building permits
Inverters
SolarEdge SE…H (HD-Wave)
6
Optimizers
SolarEdge Power Optimizer
5
Number of permits naming both this panel series and the product; 9 of 10 permits list other equipment.
Compare with similar 395 W panels
CEC PV Module List (Oct 7, 2026) · Qcells datasheet · Kiwa PVEL Scorecard · building permits
Panel
Pmax
Efficiency
γ Pmax (CEC)
Voc, V
Isc, A
PVEL (product / brand)
SoCal permits (series)
Tesla T395H
395 W
≥20.1%
−0.362
45.27
11.1
—
10
Qcells Q.PEAK DUO BLK ML-G10+ 395
395 W
≥20.1%
−0.362
45.27
11.1
product 2022, 2023
221
JA Solar JAM54S31-395/MR
395 W
≈20.8%
−0.329
36.98
13.7
product 2023, 2024
152
REC Group REC395AA Pure
395 W
≈22%
−0.256
48.7
10.2
brand 9× (2016–2025)
66
Same fields from the same sources for every row; ≈ efficiency is calculated from the listed area. Comparable series: other brands, same product group, power range covering this class.
Questions & answers
How efficient is the Tesla T395H?
The Tesla datasheet guarantees at least 20.1% module efficiency for the 395 W class (up to 20.6% for 405 W). 395 W over 1.92 m² equals about 206 W per square meter.
How much energy does one panel produce in Los Angeles or Palmdale?
PVWatts v8 with typical-year weather gives about 662 kWh per year per 395 W panel in Los Angeles and about 725 kWh in Palmdale (20° roof, facing south, 14% system losses).
How much power does it lose on a hot roof?
With γ = −0.34 %/°C, at a 77 °C cell temperature (hottest modeled hour in Palmdale) output is about 17.6% below the STC rating.
How many panels fit on one string?
With the Tesla 1538000-xx-y (max DC 600 V, MPPT from 60 V, datasheet) in Los Angeles the calculator gives 2–12 panels per string (Voc at 2 °C = 48.1 V, Vmp at 74 °C cell = 30 V). Final design must follow the inverter manual and NEC 690.7.
Does it work with Enphase IQ8PLUS-72-2-US microinverters?
Voltage check against the Enphase datasheet: Voc when cold 48.1 V vs max input 60 V; Vmp when hot 30 V vs MPPT low 29 V; recommended module power 235–440 W. Confirm on the microinverter maker’s compatibility list.
What fire rating does it have?
UL 61730 fire rating Type 2 per datasheet.
Sources
California Energy Commission — Solar Equipment Lists, PV Module List, Inverter List (snapshot Oct 7, 2026).
Tesla — manufacturer datasheet “Tesla Photovoltaic Module T395H, T400H, and T405H”.
Qcells — manufacturer datasheet “Q.PEAK DUO BLK ML-G10+ ENDURING HIGH PERFORMANCE”.
Kiwa PVEL — PV Module Reliability Scorecard, Top Performer lists.
NLR (formerly NREL) — System Advisor Model CEC inverter library (version 2026.7.3).
NLR (formerly NREL) — PVWatts v8, NSRDB PSM v3 typical-year weather for Los Angeles, Palmdale, Chula Vista, Huntington Beach, Riverside, Santa Clarita.
Inverter datasheets — APsystems (Alt Power System), Enphase, Solis (Ginlong), Tesla (manufacturer documents).
Building permits — Los Angeles County Public Works (EPIC-LA, unincorporated areas) (Oct 2021 – Sep 2022). Equipment matched from permit descriptions by model number.
Cali-Graf calculations — formulas and inputs are shown next to each calculated value (efficiency from area, temperature-corrected voltages, string sizing, energy estimates).
Get your free estimate
Three fields, and Cali Energy calls back within 30 minutes during business hours.
Thanks!
We got your request and will call back within 30 minutes during business hours.