Tesla TSP 420

360 cells. Power classes 405–430 W in the CEC list; datasheet covers 415–420 W.

CEC listed · Sep 22, 2025UL 6173025-yr product + 25-yr performance warrantyInstalled in 24 SoCal permits
Power class
  • Power (STC)420 Wtolerance +5 / −0 W
  • Efficiency≥20.5%datasheet minimum
  • %/°C Pmax−0.34CEC test: −0.345
  • Degradation / yr0.45%after year 1 (warranty)

Power classes

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation · Tesla datasheet · 6 models
ModelPmaxVoc, VIsc, AVmp, VImp, AEfficiencyPTCCEC listed
TSP-405405 W40.8712.7434.1511.86≈19.8%381 WSep 22, 2025
TSP-410410 W40.9012.8334.2011.90≈20.0%386 WSep 22, 2025
TSP-415415 W40.9212.9334.2412.12≥20.3%391 WSep 22, 2025
TSP-420420 W40.9513.0334.2912.25≥20.5%395 WSep 22, 2025
TSP-425425 W40.9813.1234.3312.38≈20.7%400 WSep 22, 2025
TSP-430430 W41.0113.2034.4312.49≈21.0%405 WSep 22, 2025
≈ efficiency = Pmax ÷ panel area 2.049 m² (datasheet size) for classes outside the datasheet.

Build & dimensions

Tesla datasheet · Cali-Graf calculation · CEC PV Module List (Oct 7, 2026)

Heat & cold behaviour

Tesla datasheet · CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation
DatasheetCEC listing test
Pmax coefficient γ−0.34 %/°C−0.345 %/°C
Voc coefficient β−0.27 %/°C−0.261 %/°C
Isc coefficient α+0.04 %/°C+0.045 %/°C
Vmp coefficient≈ −0.38 %/°C—
Operating cell temperature—NOCT 42.8 °C
Vmp coefficient ≈ γ − α (datasheet); used only for the hot-roof voltage estimate.

Away from lab conditions — CEC listing test points

ClassPmax at NOCTVmp × Imp at NOCTPmax at 200 W/m²Low-light efficiency vs STC
405 W304.1 W31.75 V × 9.58 A77.8 W96%
410 W305.6 W31.8 V × 9.61 A78.2 W95%
415 W311.6 W31.84 V × 9.79 A79.7 W96%
420 W315.4 W31.88 V × 9.89 A80.7 W96%
425 W319.1 W31.92 V × 10 A81.6 W96%
430 W322.9 W32.01 V × 10.09 A82.6 W96%
Pmax = Vmp × Imp from the CEC listing; low-light efficiency = Pmax at 200 W/m² ÷ (20% of STC Pmax).

Electrical & strength ratings

Certifications

CEC PV Module List (Oct 7, 2026) · Tesla datasheet
UL 61730IEC 61215Fire rating Type 2 (UL 61730)

Warranty & degradation

Tesla datasheet · Cali-Graf calculation
80%85%90%95%100%051015202598% yr 193.95% yr 1087.2% yr 25years
  • Product warranty25 years
  • Performance warranty25 years
  • Year 1≥ 98%
  • Then≤ 0.45% / year
  • Year 10≥ 93.95%calculated from warranty terms
  • Year 25≥ 87.2%

Inverter compatibility & string sizing

Tesla datasheet · Cali-Graf calculation · NLR PVWatts v8 · CEC PV Module List (Oct 7, 2026) · inverter datasheets · NLR SAM inverter library · CEC Grid Support Inverter List (Oct 7, 2026)
43.5 V
Voc when cold
per panel
27.9 V
Vmp when hot
per panel
13
Max panels / string
max DC 600 V
3
Min panels / string
MPPT from 60 V
Defaults come from NLR TMY weather (coldest hour, hottest modeled cell). Code calculations (NEC 690.7) use the ASHRAE extreme annual minimum, which is usually colder — enter it above.

String inverters most named in SoCal permits

InverterMax DC inputMPPTWindow sourcePanels per string
Tesla 1538000-xx-y600 V60–480 Vdatasheet3–13
Solis (Ginlong) S6-EH1P10K-H-US600 V80–520 Vdatasheet3–13
Solis (Ginlong) Solis-1P7.6K-4G-US600 V100–500 Vdatasheet4–13
Qcells Q.VOLT H7.6SX498 V234–498 VCEC test window9–11

Microinverters (one per panel)

MicroinverterRecommended module powerMax DC inputMPPTVoc cold / Vmp hotCheckDC/AC
Enphase IQ8PLUS-72-2-US235–440 W60 V29–45 V43.5 / 27.9 V⚠ Works; below MPPT at peak heat1.45
Enphase IQ8X-80-M-US320–540 W79.5 V43–60 V43.5 / 27.9 V✗ Not a match: module voltage below MPPT range1.11
APsystems (Alt Power System) DS3-L265–570 W60 V28–45 V43.5 / 27.9 V⚠ Works; below MPPT at peak heat0.54
Enphase IQ8M-72-2-US260–460 W60 V30–45 V43.5 / 27.9 V⚠ Works; below MPPT at peak heat1.29
Enphase IQ8A-72-2-US295–500 W60 V32–45 V43.5 / 27.9 V⚠ Works; below MPPT at peak heat1.2
Voltage check against the microinverter datasheets — confirm the pairing on the manufacturer’s module compatibility list. Rows appear only when the panel’s power is inside the microinverter’s recommended module power range.
SolarEdge and other optimizer-based systems size strings by the optimizer rules — use the manufacturer’s designer. Reference inverters: most named in SoCal permits since Oct 2024.

Expected production in Southern California

NLR PVWatts v8 · Cali-Graf calculation
CitykWh / kW / yrkWh / panel / yrkWh / system / yrSun, kWh/m²/day
Los Angeles1,67670411,9676.08
Palmdale1,83577113,1026.69
Chula Vista1,69671212,1096.11
Huntington Beach1,64369011,7315.89
Riverside1,69671212,1096.21
Santa Clarita1,72472412,3096.28
781Jan782Feb1,003Mar1,108Apr1,095May1,163Jun1,225Jul1,240Aug1,084Sep956Oct822Nov711DeckWh per month · Los Angeles
Estimate for comparison, not a quote: shading, roof orientation and local losses change real output. Roof mount, 20° tilt, south, 14% system losses.

Who installs TSP panels in SoCal

building permits · CSLB License Master
24
Permits naming this series
Oct 2025 – Sep 2026
2
Licensed installers
CSLB license on the permit
1
Jurisdictions so far
Palmdale (24)

Permits over time

1Oct ’251Nov0Dec1Jan ’261Feb2Mar2Apr3May3Jun4Jul4Aug2Seppermits per month

Top ZIP codes

  • ZIP 9355117
  • ZIP 935504
  • ZIP 935523

Typical system

median 8.8 kW, 21 panels (n = 23)

Only installer and ZIP level is shown — no homeowner names, street addresses or permit numbers. Counts grow as more permit portals are loaded.

Installed together with

building permits

Batteries

Tesla Powerwall 3
24
Tesla Powerwall 3 Expansion
9
Number of permits naming both this panel series and the product; 24 of 24 permits list other equipment.

Compare with similar 420 W panels

CEC PV Module List (Oct 7, 2026) · datasheets · Kiwa PVEL Scorecard · building permits
PanelPmaxEfficiencyγ Pmax (CEC)Voc, VIsc, AWarrantyPVEL (product / brand)SoCal permits (series)
Tesla TSP 420420 W≥20.5%−0.34540.9513.0325 / 25 yr—24
Qcells Q.PEAK DUO BLK ML-G10+ 415415 W≈21.1%−0.33745.4111.2325 / 25 yrproduct 2022, 2023221
LONGi LR5-54HABB-415M415 W≈21.8%−0.34237.7713.94—brand 9× (2017–2026)64
Canadian Solar CS3N-420MS420 W≥20.7%−0.33245.311.7425 yrproduct 202346
Same fields from the same sources for every row; ≈ efficiency is calculated from the listed area. Comparable series: other brands, same product group, power range covering this class.

Documents

manufacturer documents

Questions & answers

How efficient is the Tesla TSP 420?

The Tesla datasheet guarantees at least 20.5% module efficiency for the 420 W class. 420 W over 2.05 m² equals about 205 W per square meter.

How much energy does one panel produce in Los Angeles or Palmdale?

PVWatts v8 with typical-year weather gives about 704 kWh per year per 420 W panel in Los Angeles and about 771 kWh in Palmdale (20° roof, facing south, 14% system losses).

How much power does it lose on a hot roof?

With γ = −0.34 %/°C, at a 77 °C cell temperature (hottest modeled hour in Palmdale) output is about 17.6% below the STC rating.

How many panels fit on one string?

With the Tesla 1538000-xx-y (max DC 600 V, MPPT from 60 V, datasheet) in Los Angeles the calculator gives 3–13 panels per string (Voc at 2 °C = 43.5 V, Vmp at 74 °C cell = 27.9 V). Final design must follow the inverter manual and NEC 690.7.

What does the warranty cover?

25 years on the product and 25 years on performance: at least 98% of rated power in year 1, then no more than 0.45% per year — at least 87.2% after 25 years (manufacturer datasheet).

How big and heavy is it?

71.1 × 44.7 × 1.57 in (1,805 × 1,135 × 40 mm), 49.2 lb (22.3 kg).

What fire rating does it have?

UL 61730 fire rating Type 2 per datasheet.

Who installs it in Southern California?

Building permits name this series 24 times (Oct 2025 – Sep 2026). The most active licensed installers are Tesla Energy Operations Inc, Solar Shoppers Construction.

Sources

  1. California Energy Commission — Solar Equipment Lists, PV Module List, Inverter List (snapshot Oct 7, 2026).
  2. Tesla — datasheet Tesla Solar Panel Datasheet.
  3. Qcells — manufacturer datasheet “Q.PEAK DUO BLK ML-G10+ ENDURING HIGH PERFORMANCE”.
  4. Canadian Solar — manufacturer datasheet “HiKu Mono PERC CS3N-400|405|410|415|420|425MS MORE POWER”.
  5. Tesla — document library on the manufacturer’s website (links above).
  6. Kiwa PVEL — PV Module Reliability Scorecard, Top Performer lists.
  7. NLR (formerly NREL) — System Advisor Model CEC inverter library (version 2026.7.3).
  8. NLR (formerly NREL) — PVWatts v8, NSRDB PSM v3 typical-year weather for Los Angeles, Palmdale, Chula Vista, Huntington Beach, Riverside, Santa Clarita.
  9. Inverter datasheets — APsystems (Alt Power System), Enphase, Solis (Ginlong), Tesla (manufacturer documents).
  10. Building permits — City of Palmdale (Oct 2025 – Sep 2026). Equipment matched from permit descriptions by model number.
  11. Contractors State License Board — License Master (contractor names and license status), as of Oct 5, 2026.
  12. Cali-Graf calculations — formulas and inputs are shown next to each calculated value (efficiency from area, temperature-corrected voltages, string sizing, energy estimates).