Defaults come from NLR TMY weather (coldest hour, hottest modeled cell). Code calculations (NEC 690.7) use the ASHRAE extreme annual minimum, which is usually colder — enter it above. β is the CEC-measured coefficient; NEC 690.7 calculations use the datasheet value.
Integrated roof products are wired per the manufacturer’s system design.
SolarEdge and other optimizer-based systems size strings by the optimizer rules — use the manufacturer’s designer. Reference inverters: most named in SoCal permits since Oct 2024.
Expected production in Southern California
NLR PVWatts v8 · Cali-Graf calculation
City
kWh / kW / yr
kWh / panel / yr
kWh / system / yr
Sun, kWh/m²/day
Los Angeles
1,676
121
11,705
6.08
Palmdale
1,835
132
12,816
6.69
Chula Vista
1,696
122
11,845
6.11
Huntington Beach
1,643
118
11,475
5.89
Riverside
1,696
122
11,845
6.21
Santa Clarita
1,724
124
12,040
6.28
PVWatts models a standard roof-mounted module; integrated roof products are not modeled separately.
Estimate for comparison, not a quote: shading, roof orientation and local losses change real output. Roof mount, 20° tilt, south, 14% system losses.
Who installs SRxxT3R panels in SoCal
building permits
4
Permits naming this series
Mar 2025 – Jun 2025
1
Jurisdictions so far
LA County (unincorp.) (4)
Permits over time
Only installer and ZIP level is shown — no homeowner names, street addresses or permit numbers. Permits from LA County (unincorp.) come without a contractor license, so they count toward totals but not toward installers. Counts grow as more permit portals are loaded.
Installed together with
building permits
Batteries
Tesla Powerwall 3
3
Tesla Powerwall 3 Expansion
3
Number of permits naming both this panel series and the product; 3 of 4 permits list other equipment.
Questions & answers
How efficient is the Tesla SR72T3R?
Calculated from the panel area (0.46 m²): about 14.7% for the 72 W class. 72 W over 0.46 m² equals about 155 W per square meter.
How much energy does one panel produce in Los Angeles or Palmdale?
PVWatts v8 with typical-year weather gives about 121 kWh per year per 72 W panel in Los Angeles and about 132 kWh in Palmdale (20° roof, facing south, 14% system losses).
How much power does it lose on a hot roof?
With γ = −0.372 %/°C, at a 77 °C cell temperature (hottest modeled hour in Palmdale) output is about 19.3% below the STC rating.
Sources
California Energy Commission — Solar Equipment Lists, PV Module List (snapshot Oct 7, 2026).
NLR (formerly NREL) — PVWatts v8, NSRDB PSM v3 typical-year weather for Los Angeles, Palmdale, Chula Vista, Huntington Beach, Riverside, Santa Clarita.
Building permits — Los Angeles County Public Works (EPIC-LA, unincorporated areas) (Mar 2025 – Jun 2025). Equipment matched from permit descriptions by model number.
Cali-Graf calculations — formulas and inputs are shown next to each calculated value (efficiency from area, temperature-corrected voltages, string sizing, energy estimates).
Get your free estimate
Three fields, and Cali Energy calls back within 30 minutes during business hours.
Thanks!
We got your request and will call back within 30 minutes during business hours.