Vmp coefficient ≈ γ − α (datasheet); used only for the hot-roof voltage estimate.
At normal operating conditions (NMOT, 800 W/m²) — datasheet
Class
Pmax, W
Voc, V
Isc, A
Vmp, V
Imp, A
395 W
294.0
34.60
11.04
28.80
10.23
400 W
298.0
34.80
11.11
29.00
10.30
405 W
302.0
35.10
11.17
29.20
10.36
410 W
306.0
35.30
11.24
29.30
10.42
Away from lab conditions — CEC listing test points
Class
Pmax at NOCT
Vmp × Imp at NOCT
Pmax at 200 W/m²
Low-light efficiency vs STC
395 W
286.6 W
27.77 V × 10.32 A
75.7 W
96%
400 W
290.3 W
27.95 V × 10.39 A
76.6 W
96%
405 W
293.9 W
28.12 V × 10.45 A
77.6 W
96%
410 W
297.5 W
28.29 V × 10.52 A
78.5 W
96%
415 W
301.3 W
28.48 V × 10.58 A
79.5 W
96%
Pmax = Vmp × Imp from the CEC listing; low-light efficiency = Pmax at 200 W/m² ÷ (20% of STC Pmax).
Electrical & strength ratings
Talesun datasheet
Max system voltage1,500 V
Max series fuse25 A
Design load push / pull113 psf5,400 Pa
Module temperature−40 °F to +185 °F−40 °C to +85 °C
Packaging: 36 per pallet · 936 per container
Certifications
CEC PV Module List (Oct 7, 2026) · Talesun datasheet
UL 61730IEC 61215IEC 61730ISO 14001ISO 45001ISO 9001
UL 61730CEC listing
IEC 61215datasheet
IEC 61730datasheet
ISO 14001factory, datasheet
ISO 45001factory, datasheet
ISO 9001factory, datasheet
Independent reliability testing
Kiwa PVEL Scorecard · RETC PV Module Index
5
PVEL Scorecards
Talesun named Top Performer, 2017–2025
1
RETC PV Module Index
Talesun, 2024
This exact series is not listed in published PVEL Top Performer tables. Results below are for the manufacturer.
RETC PV Module Index — Talesun
Year
Recognition
2024
Test Category High Achiever
Inverter compatibility & string sizing
Talesun datasheet · Cali-Graf calculation · NLR PVWatts v8 · CEC PV Module List (Oct 7, 2026) · inverter datasheets · NLR SAM inverter library · CEC Grid Support Inverter List (Oct 7, 2026)
39.5 V
Voc when cold
per panel
25.1 V
Vmp when hot
per panel
15
Max panels / string
max DC 600 V
3
Min panels / string
MPPT from 60 V
Defaults come from NLR TMY weather (coldest hour, hottest modeled cell). Code calculations (NEC 690.7) use the ASHRAE extreme annual minimum, which is usually colder — enter it above.
String inverters most named in SoCal permits
Inverter
Max DC input
MPPT
Window source
Panels per string
Tesla 1538000-xx-y
600 V
60–480 V
datasheet
3–15
Solis (Ginlong) S6-EH1P10K-H-US
600 V
80–520 V
datasheet
4–15
Solis (Ginlong) Solis-1P7.6K-4G-US
600 V
100–500 V
datasheet
4–15
Qcells Q.VOLT H7.6SX
498 V
234–498 V
CEC test window
10–12
Microinverters (one per panel)
Microinverter
Recommended module power
Max DC input
MPPT
Voc cold / Vmp hot
Check
DC/AC
Enphase IQ8PLUS-72-2-US
235–440 W
60 V
29–45 V
39.5 / 25.1 V
⚠ Works; below MPPT at peak heat
1.4
Enphase IQ8X-80-M-US
320–540 W
79.5 V
43–60 V
39.5 / 25.1 V
✗ Not a match: module voltage below MPPT range
1.07
APsystems (Alt Power System) DS3-L
265–570 W
60 V
28–45 V
39.5 / 25.1 V
⚠ Works; below MPPT at peak heat
0.52
Enphase IQ8M-72-2-US
260–460 W
60 V
30–45 V
39.5 / 25.1 V
⚠ Works; below MPPT at peak heat
1.25
Enphase IQ8A-72-2-US
295–500 W
60 V
32–45 V
39.5 / 25.1 V
✗ Not a match: module voltage below MPPT range
1.16
Voltage check against the microinverter datasheets — confirm the pairing on the manufacturer’s module compatibility list. Rows appear only when the panel’s power is inside the microinverter’s recommended module power range.
SolarEdge and other optimizer-based systems size strings by the optimizer rules — use the manufacturer’s designer. Reference inverters: most named in SoCal permits since Oct 2024.
Expected production in Southern California
NLR PVWatts v8 · Cali-Graf calculation
City
kWh / kW / yr
kWh / panel / yr
kWh / system / yr
Sun, kWh/m²/day
Los Angeles
1,676
679
11,539
6.08
Palmdale
1,835
743
12,634
6.69
Chula Vista
1,696
687
11,677
6.11
Huntington Beach
1,643
665
11,312
5.89
Riverside
1,696
687
11,677
6.21
Santa Clarita
1,724
698
11,870
6.28
Estimate for comparison, not a quote: shading, roof orientation and local losses change real output. Roof mount, 20° tilt, south, 14% system losses.
Compare with similar 405 W panels
CEC PV Module List (Oct 7, 2026) · Qcells datasheet · Kiwa PVEL Scorecard · building permits
Panel
Pmax
Efficiency
γ Pmax (CEC)
Voc, V
Isc, A
PVEL (product / brand)
SoCal permits (series)
Talesun TP7F54M(H) 405
405 W
≥20.7%
−0.358
37.25
13.86
brand 5×
—
Qcells Q.PEAK DUO BLK ML-G10+ 405
405 W
≥20.6%
−0.362
45.34
11.17
product 2022, 2023
221
JA Solar JAM54S31-405/MR
405 W
≈21.3%
−0.329
37.23
13.87
product 2023, 2024
152
REC Group REC405AA Pure
405 W
≈22.6%
−0.256
48.9
10.3
brand 9× (2016–2025)
66
Same fields from the same sources for every row; ≈ efficiency is calculated from the listed area. Comparable series: other brands, same product group, power range covering this class.
About Talesun
CEC PV Module List (Oct 7, 2026) · Kiwa PVEL Scorecard · RETC PV Module Index · building permits
ManufacturerTalesun
Listed in CEC asSuzhou Talesun Solar Technologies Co., Ltd.
PVEL Top Performer (manufacturer)5 Scorecards (2017–2025)
RETC PV Module Index2024
Current panel series in CEC list34
Other series by SoCal permits
TM7G54M · 1TM3F48MTM3F66MTM3G48MTM3G66MTM7F54M
Questions & answers
How efficient is the Talesun TP7F54M(H) 405?
The Talesun datasheet guarantees at least 20.7% module efficiency for the 405 W class (up to 21% for 410 W). 405 W over 1.95 m² equals about 207 W per square meter.
How much energy does one panel produce in Los Angeles or Palmdale?
PVWatts v8 with typical-year weather gives about 679 kWh per year per 405 W panel in Los Angeles and about 743 kWh in Palmdale (20° roof, facing south, 14% system losses).
How much power does it lose on a hot roof?
With γ = −0.35 %/°C, at a 77 °C cell temperature (hottest modeled hour in Palmdale) output is about 18.1% below the STC rating.
How many panels fit on one string?
With the Tesla 1538000-xx-y (max DC 600 V, MPPT from 60 V, datasheet) in Los Angeles the calculator gives 3–15 panels per string (Voc at 2 °C = 39.5 V, Vmp at 74 °C cell = 25.1 V). Final design must follow the inverter manual and NEC 690.7.
NLR (formerly NREL) — System Advisor Model CEC inverter library (version 2026.7.3).
NLR (formerly NREL) — PVWatts v8, NSRDB PSM v3 typical-year weather for Los Angeles, Palmdale, Chula Vista, Huntington Beach, Riverside, Santa Clarita.
Inverter datasheets — APsystems (Alt Power System), Enphase, Solis (Ginlong), Tesla (manufacturer documents).
Building permits — Southern California permit portals. Equipment matched from permit descriptions.
Cali-Graf calculations — formulas and inputs are shown next to each calculated value (efficiency from area, temperature-corrected voltages, string sizing, energy estimates).
Get your free estimate
Three fields, and Cali Energy calls back within 30 minutes during business hours.
Thanks!
We got your request and will call back within 30 minutes during business hours.