Cali-GrafCali-Graf
Solar panelTalesun

Talesun TP7F54M(H) 405

108 half-cut cells, PERC. Power classes 395–415 W in the CEC list; datasheet covers 390–410 W.

CEC listed · Mar 1, 2022UL 61730PERC
Power class
  • Power (STC)405 WCEC nameplate
  • Efficiency≥20.7%datasheet minimum
  • %/°C Pmax−0.35CEC test: −0.358
  • PTC / STC93.2%PTC 378 W (CEC)

Power classes

CEC PV Module List (Oct 7, 2026) · Talesun datasheet · Cali-Graf calculation · 5 models
ModelPmaxVoc, VIsc, AVmp, VImp, AEfficiencyPTCCEC listed
TP7F54M(H)-395395 W36.7513.6930.8512.81≥20.2%368 WMar 1, 2022
TP7F54M(H)-400400 W37.0013.7831.0512.89≥20.5%373 WMar 1, 2022
TP7F54M(H)-405405 W37.2513.8631.2412.97≥20.7%378 WMar 1, 2022
TP7F54M(H)-410410 W37.5013.9431.4313.05≥21.0%382 WMar 1, 2022
TP7F54M(H)-415415 W37.7514.0231.6413.13≈21.3%387 WMar 1, 2022
≈ efficiency = Pmax ÷ panel area 1.953 m² (datasheet size) for classes outside the datasheet.

Build & dimensions

Talesun datasheet · Cali-Graf calculation · CEC PV Module List (Oct 7, 2026)

Heat & cold behaviour

Talesun datasheet · CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation
DatasheetCEC listing test
Pmax coefficient γ−0.35 %/°C−0.358 %/°C
Voc coefficient β−0.26 %/°C−0.279 %/°C
Isc coefficient α+0.05 %/°C+0.051 %/°C
Vmp coefficient≈ −0.40 %/°C—
Operating cell temperatureNMOT 43 ± 2 °CNOCT 44.8 °C
Vmp coefficient ≈ γ − α (datasheet); used only for the hot-roof voltage estimate.

At normal operating conditions (NMOT, 800 W/m²) — datasheet

ClassPmax, WVoc, VIsc, AVmp, VImp, A
395 W294.034.6011.0428.8010.23
400 W298.034.8011.1129.0010.30
405 W302.035.1011.1729.2010.36
410 W306.035.3011.2429.3010.42

Away from lab conditions — CEC listing test points

ClassPmax at NOCTVmp × Imp at NOCTPmax at 200 W/m²Low-light efficiency vs STC
395 W286.6 W27.77 V × 10.32 A75.7 W96%
400 W290.3 W27.95 V × 10.39 A76.6 W96%
405 W293.9 W28.12 V × 10.45 A77.6 W96%
410 W297.5 W28.29 V × 10.52 A78.5 W96%
415 W301.3 W28.48 V × 10.58 A79.5 W96%
Pmax = Vmp × Imp from the CEC listing; low-light efficiency = Pmax at 200 W/m² ÷ (20% of STC Pmax).

Electrical & strength ratings

Talesun datasheet
Packaging: 36 per pallet · 936 per container

Certifications

CEC PV Module List (Oct 7, 2026) · Talesun datasheet
UL 61730IEC 61215IEC 61730ISO 14001ISO 45001ISO 9001

Independent reliability testing

Kiwa PVEL Scorecard · RETC PV Module Index
5
PVEL Scorecards
Talesun named Top Performer, 2017–2025
1
RETC PV Module Index
Talesun, 2024
This exact series is not listed in published PVEL Top Performer tables. Results below are for the manufacturer.

RETC PV Module Index — Talesun

YearRecognition
2024Test Category High Achiever

Inverter compatibility & string sizing

Talesun datasheet · Cali-Graf calculation · NLR PVWatts v8 · CEC PV Module List (Oct 7, 2026) · inverter datasheets · NLR SAM inverter library · CEC Grid Support Inverter List (Oct 7, 2026)
39.5 V
Voc when cold
per panel
25.1 V
Vmp when hot
per panel
15
Max panels / string
max DC 600 V
3
Min panels / string
MPPT from 60 V
Defaults come from NLR TMY weather (coldest hour, hottest modeled cell). Code calculations (NEC 690.7) use the ASHRAE extreme annual minimum, which is usually colder — enter it above.

String inverters most named in SoCal permits

InverterMax DC inputMPPTWindow sourcePanels per string
Tesla 1538000-xx-y600 V60–480 Vdatasheet3–15
Solis (Ginlong) S6-EH1P10K-H-US600 V80–520 Vdatasheet4–15
Solis (Ginlong) Solis-1P7.6K-4G-US600 V100–500 Vdatasheet4–15
Qcells Q.VOLT H7.6SX498 V234–498 VCEC test window10–12

Microinverters (one per panel)

MicroinverterRecommended module powerMax DC inputMPPTVoc cold / Vmp hotCheckDC/AC
Enphase IQ8PLUS-72-2-US235–440 W60 V29–45 V39.5 / 25.1 V⚠ Works; below MPPT at peak heat1.4
Enphase IQ8X-80-M-US320–540 W79.5 V43–60 V39.5 / 25.1 V✗ Not a match: module voltage below MPPT range1.07
APsystems (Alt Power System) DS3-L265–570 W60 V28–45 V39.5 / 25.1 V⚠ Works; below MPPT at peak heat0.52
Enphase IQ8M-72-2-US260–460 W60 V30–45 V39.5 / 25.1 V⚠ Works; below MPPT at peak heat1.25
Enphase IQ8A-72-2-US295–500 W60 V32–45 V39.5 / 25.1 V✗ Not a match: module voltage below MPPT range1.16
Voltage check against the microinverter datasheets — confirm the pairing on the manufacturer’s module compatibility list. Rows appear only when the panel’s power is inside the microinverter’s recommended module power range.
SolarEdge and other optimizer-based systems size strings by the optimizer rules — use the manufacturer’s designer. Reference inverters: most named in SoCal permits since Oct 2024.

Expected production in Southern California

NLR PVWatts v8 · Cali-Graf calculation
CitykWh / kW / yrkWh / panel / yrkWh / system / yrSun, kWh/m²/day
Los Angeles1,67667911,5396.08
Palmdale1,83574312,6346.69
Chula Vista1,69668711,6776.11
Huntington Beach1,64366511,3125.89
Riverside1,69668711,6776.21
Santa Clarita1,72469811,8706.28
753Jan754Feb967Mar1,069Apr1,055May1,122Jun1,181Jul1,195Aug1,045Sep922Oct792Nov686DeckWh per month · Los Angeles
Estimate for comparison, not a quote: shading, roof orientation and local losses change real output. Roof mount, 20° tilt, south, 14% system losses.

Compare with similar 405 W panels

CEC PV Module List (Oct 7, 2026) · Qcells datasheet · Kiwa PVEL Scorecard · building permits
PanelPmaxEfficiencyγ Pmax (CEC)Voc, VIsc, APVEL (product / brand)SoCal permits (series)
Talesun TP7F54M(H) 405405 W≥20.7%−0.35837.2513.86brand 5×—
Qcells Q.PEAK DUO BLK ML-G10+ 405405 W≥20.6%−0.36245.3411.17product 2022, 2023221
JA Solar JAM54S31-405/MR405 W≈21.3%−0.32937.2313.87product 2023, 2024152
REC Group REC405AA Pure405 W≈22.6%−0.25648.910.3brand 9× (2016–2025)66
Same fields from the same sources for every row; ≈ efficiency is calculated from the listed area. Comparable series: other brands, same product group, power range covering this class.

About Talesun

CEC PV Module List (Oct 7, 2026) · Kiwa PVEL Scorecard · RETC PV Module Index · building permits

Other series by SoCal permits

TM7G54M · 1TM3F48MTM3F66MTM3G48MTM3G66MTM7F54M

Questions & answers

How efficient is the Talesun TP7F54M(H) 405?

The Talesun datasheet guarantees at least 20.7% module efficiency for the 405 W class (up to 21% for 410 W). 405 W over 1.95 m² equals about 207 W per square meter.

How much energy does one panel produce in Los Angeles or Palmdale?

PVWatts v8 with typical-year weather gives about 679 kWh per year per 405 W panel in Los Angeles and about 743 kWh in Palmdale (20° roof, facing south, 14% system losses).

How much power does it lose on a hot roof?

With γ = −0.35 %/°C, at a 77 °C cell temperature (hottest modeled hour in Palmdale) output is about 18.1% below the STC rating.

How many panels fit on one string?

With the Tesla 1538000-xx-y (max DC 600 V, MPPT from 60 V, datasheet) in Los Angeles the calculator gives 3–15 panels per string (Voc at 2 °C = 39.5 V, Vmp at 74 °C cell = 25.1 V). Final design must follow the inverter manual and NEC 690.7.

How big and heavy is it?

67.8 × 44.6 × 1.18 in (1,722 × 1,134 × 30 mm), 47.4 lb (21.5 kg).

Has this panel been reliability-tested?

This exact series is not in published PVEL Top Performer tables; Talesun was named a Top Performer in 5 Scorecards (2017–2025).

Sources

  1. California Energy Commission — Solar Equipment Lists, PV Module List, Inverter List (snapshot Oct 7, 2026).
  2. Talesun — manufacturer datasheet “TP7F54M TP7F54M(H) 108-cell 10BB Half-cut Mono Perc”.
  3. Qcells — manufacturer datasheet “Q.PEAK DUO BLK ML-G10+ ENDURING HIGH PERFORMANCE”.
  4. Kiwa PVEL — PV Module Reliability Scorecard, Top Performer lists 2017–2025.
  5. RETC — PV Module Index report.
  6. NLR (formerly NREL) — System Advisor Model CEC inverter library (version 2026.7.3).
  7. NLR (formerly NREL) — PVWatts v8, NSRDB PSM v3 typical-year weather for Los Angeles, Palmdale, Chula Vista, Huntington Beach, Riverside, Santa Clarita.
  8. Inverter datasheets — APsystems (Alt Power System), Enphase, Solis (Ginlong), Tesla (manufacturer documents).
  9. Building permits — Southern California permit portals. Equipment matched from permit descriptions.
  10. Cali-Graf calculations — formulas and inputs are shown next to each calculated value (efficiency from area, temperature-corrected voltages, string sizing, energy estimates).