Cali-GrafCali-Graf
Solar panelTalesun

Talesun TP6F60M 335

120 half-cut cells. Power classes 325–350 W in the CEC list.

CEC listed · Sep 1, 2020UL 61730
Power class
  • Power (STC)335 WCEC nameplate
  • Efficiency≈19.8%calculated from area
  • %/°C Pmax−0.392CEC listing test
  • PTC / STC92.2%PTC 309 W (CEC)

Power classes

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation · 6 models
ModelPmaxVoc, VIsc, AVmp, VImp, AEfficiencyPTCCEC listed
TP6F60M-325325 W40.3010.0633.809.61≈19.3%300 WSep 1, 2020
TP6F60M-330330 W40.5010.1234.109.66≈19.6%304 WSep 1, 2020
TP6F60M-335335 W40.7010.1834.409.74≈19.8%309 WSep 1, 2020
TP6F60M-340340 W40.9010.2434.709.80≈20.1%314 WOct 21, 2020
TP6F60M-345345 W41.1010.3434.909.89≈20.4%318 WOct 21, 2020
TP6F60M-350350 W41.6010.3835.309.91≈20.7%323 WOct 21, 2020
≈ efficiency = Pmax ÷ CEC-listed area 1.69 m².

Build & dimensions

CEC PV Module List (Oct 7, 2026)

Heat & cold behaviour

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation
CEC listing test
Pmax coefficient γ−0.392 %/°C
Voc coefficient β−0.286 %/°C
Isc coefficient α+0.028 %/°C
Operating cell temperatureNOCT 45.5 °C
Vmp coefficient ≈ γ − α (CEC); used only for the hot-roof voltage estimate.

Away from lab conditions — CEC listing test points

ClassPmax at NOCTVmp × Imp at NOCTPmax at 200 W/m²Low-light efficiency vs STC
325 W243.3 W30.34 V × 8.02 A62.7 W96%
330 W246.7 W30.61 V × 8.06 A63.6 W96%
335 W246.7 W30.61 V × 8.06 A63.6 W95%
340 W250.4 W30.88 V × 8.11 A64.5 W95%
345 W254.2 W31.06 V × 8.18 A65.5 W95%
350 W257.6 W31.41 V × 8.2 A66.4 W95%
Pmax = Vmp × Imp from the CEC listing; low-light efficiency = Pmax at 200 W/m² ÷ (20% of STC Pmax).

Certifications

CEC PV Module List (Oct 7, 2026)
UL 61730IEC 61215

Independent reliability testing

Kiwa PVEL Scorecard · RETC PV Module Index
5
PVEL Scorecards
Talesun named Top Performer, 2017–2025
1
RETC PV Module Index
Talesun, 2024
This exact series is not listed in published PVEL Top Performer tables. Results below are for the manufacturer.

RETC PV Module Index — Talesun

YearRecognition
2024Test Category High Achiever

Inverter compatibility & string sizing

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation · NLR PVWatts v8 · inverter datasheets · NLR SAM inverter library · CEC Grid Support Inverter List (Oct 7, 2026)
43.4 V
Voc when cold
per panel
27.3 V
Vmp when hot
per panel
13
Max panels / string
max DC 600 V
3
Min panels / string
MPPT from 60 V
Defaults come from NLR TMY weather (coldest hour, hottest modeled cell). Code calculations (NEC 690.7) use the ASHRAE extreme annual minimum, which is usually colder — enter it above. β is the CEC-measured coefficient; NEC 690.7 calculations use the datasheet value.

String inverters most named in SoCal permits

InverterMax DC inputMPPTWindow sourcePanels per string
Tesla 1538000-xx-y600 V60–480 Vdatasheet3–13
Solis (Ginlong) S6-EH1P10K-H-US600 V80–520 Vdatasheet3–13
Solis (Ginlong) Solis-1P7.6K-4G-US600 V100–500 Vdatasheet4–13
Qcells Q.VOLT H7.6SX498 V234–498 VCEC test window9–11

Microinverters (one per panel)

MicroinverterRecommended module powerMax DC inputMPPTVoc cold / Vmp hotCheckDC/AC
Enphase IQ8PLUS-72-2-US235–440 W60 V29–45 V43.4 / 27.3 V⚠ Works; below MPPT at peak heat1.16
Enphase IQ8X-80-M-US320–540 W79.5 V43–60 V43.4 / 27.3 V✗ Not a match: module voltage below MPPT range0.88
APsystems (Alt Power System) DS3-L265–570 W60 V28–45 V43.4 / 27.3 V⚠ Works; below MPPT at peak heat0.43
Enphase IQ8M-72-2-US260–460 W60 V30–45 V43.4 / 27.3 V⚠ Works; below MPPT at peak heat1.03
Enphase IQ8A-72-2-US295–500 W60 V32–45 V43.4 / 27.3 V⚠ Works; below MPPT at peak heat0.96
Voltage check against the microinverter datasheets — confirm the pairing on the manufacturer’s module compatibility list. Rows appear only when the panel’s power is inside the microinverter’s recommended module power range.
SolarEdge and other optimizer-based systems size strings by the optimizer rules — use the manufacturer’s designer. Reference inverters: most named in SoCal permits since Oct 2024.

Expected production in Southern California

NLR PVWatts v8 · Cali-Graf calculation
CitykWh / kW / yrkWh / panel / yrkWh / system / yrSun, kWh/m²/day
Los Angeles1,67656111,7916.08
Palmdale1,83561512,9096.69
Chula Vista1,69656811,9316.11
Huntington Beach1,64355011,5595.89
Riverside1,69656811,9316.21
Santa Clarita1,72457812,1286.28
770Jan770Feb988Mar1,092Apr1,078May1,146Jun1,207Jul1,221Aug1,068Sep942Oct810Nov701DeckWh per month · Los Angeles
Estimate for comparison, not a quote: shading, roof orientation and local losses change real output. Roof mount, 20° tilt, south, 14% system losses.

Compare with similar 335 W panels

CEC PV Module List (Oct 7, 2026) · Kiwa PVEL Scorecard · JinkoSolar datasheets · building permits
PanelPmaxEfficiencyγ Pmax (CEC)Voc, VIsc, APVEL (product / brand)SoCal permits (series)
Talesun TP6F60M 335335 W≈19.8%−0.39240.710.18brand 5×—
LONGi LR4-60HPB-335M335 W≈18.5%−0.33739.910.76product 2021, 2022193
JinkoSolar JKM335M-60HBL335 W≈19.9%−0.40640.810.73brand 12× (2014–2026)45
REC Group REC340AA340 W≈20.2%−0.27943.110.09brand 9× (2016–2025)30
Same fields from the same sources for every row; ≈ efficiency is calculated from the listed area. Comparable series: other brands, same product group, power range covering this class.

About Talesun

CEC PV Module List (Oct 7, 2026) · Kiwa PVEL Scorecard · RETC PV Module Index · building permits

Other series by SoCal permits

TM7G54M · 1TM3F48MTM3F66MTM3G48MTM3G66MTM7F54M

Questions & answers

How efficient is the Talesun TP6F60M 335?

Calculated from the panel area (1.69 m²): about 19.8% for the 335 W class. 335 W over 1.69 m² equals about 198 W per square meter.

How much energy does one panel produce in Los Angeles or Palmdale?

PVWatts v8 with typical-year weather gives about 561 kWh per year per 335 W panel in Los Angeles and about 615 kWh in Palmdale (20° roof, facing south, 14% system losses).

How much power does it lose on a hot roof?

With γ = −0.392 %/°C, at a 77 °C cell temperature (hottest modeled hour in Palmdale) output is about 20.3% below the STC rating.

How many panels fit on one string?

With the Tesla 1538000-xx-y (max DC 600 V, MPPT from 60 V, datasheet) in Los Angeles the calculator gives 3–13 panels per string (Voc at 2 °C = 43.4 V, Vmp at 74 °C cell = 27.3 V). Final design must follow the inverter manual and NEC 690.7.

Has this panel been reliability-tested?

This exact series is not in published PVEL Top Performer tables; Talesun was named a Top Performer in 5 Scorecards (2017–2025).

Sources

  1. California Energy Commission — Solar Equipment Lists, PV Module List, Inverter List (snapshot Oct 7, 2026).
  2. JinkoSolar — datasheet THE MOST DEPENDABLE SOLAR BRAND.
  3. JinkoSolar — manufacturer datasheet “Eagle HC 60M G2 315-335 Watt MONO PERC HALF CELL MODULE”.
  4. Kiwa PVEL — PV Module Reliability Scorecard, Top Performer lists 2017–2025.
  5. RETC — PV Module Index report.
  6. NLR (formerly NREL) — System Advisor Model CEC inverter library (version 2026.7.3).
  7. NLR (formerly NREL) — PVWatts v8, NSRDB PSM v3 typical-year weather for Los Angeles, Palmdale, Chula Vista, Huntington Beach, Riverside, Santa Clarita.
  8. Inverter datasheets — APsystems (Alt Power System), Enphase, Solis (Ginlong), Tesla (manufacturer documents).
  9. Building permits — Southern California permit portals. Equipment matched from permit descriptions.
  10. Cali-Graf calculations — formulas and inputs are shown next to each calculated value (efficiency from area, temperature-corrected voltages, string sizing, energy estimates).