Cali-GrafCali-Graf
Solar panelTalesun

Talesun TM3F66M 610

132 half-cut cells. Power classes 590–635 W in the CEC list.

CEC listed · Jul 13, 2026UL 61730
Power class
  • Power (STC)610 WCEC nameplate
  • Efficiency≈22.8%calculated from area
  • %/°C Pmax−0.291CEC listing test
  • PTC / STC95.1%PTC 580 W (CEC)

Power classes

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation · 10 models
ModelPmaxVoc, VIsc, AVmp, VImp, AEfficiencyPTCCEC listed
TM3F66M-590590 W47.8015.7239.7014.87≈22.0%561 WJul 13, 2026
TM3F66M-595595 W48.1015.7640.0014.89≈22.2%566 WJul 13, 2026
TM3F66M-600600 W48.4015.8040.3014.91≈22.4%570 WJul 13, 2026
TM3F66M-605605 W48.7015.8340.5014.94≈22.6%575 WJul 13, 2026
TM3F66M-610610 W49.0015.8640.8014.96≈22.8%580 WJul 13, 2026
TM3F66M-615615 W49.3015.9041.0015.00≈22.9%585 WJul 13, 2026
TM3F66M-620620 W49.6015.9441.2015.05≈23.1%590 WJul 13, 2026
TM3F66M-625625 W49.9015.9841.4015.10≈23.3%595 WJul 13, 2026
TM3F66M-630630 W50.2016.0241.6015.15≈23.5%600 WJul 13, 2026
TM3F66M-635635 W50.5016.0641.8015.19≈23.7%605 WJul 13, 2026
≈ efficiency = Pmax ÷ CEC-listed area 2.68 m².

Build & dimensions

CEC PV Module List (Oct 7, 2026)

Heat & cold behaviour

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation
CEC listing test
Pmax coefficient γ−0.291 %/°C
Voc coefficient β−0.251 %/°C
Isc coefficient α+0.042 %/°C
Operating cell temperatureNOCT 43.3 °C
Vmp coefficient ≈ γ − α (CEC); used only for the hot-roof voltage estimate.

Away from lab conditions — CEC listing test points

ClassPmax at NOCTVmp × Imp at NOCTPmax at 200 W/m²Low-light efficiency vs STC
590 W445.9 W37.48 V × 11.9 A111.3 W94%
595 W449.8 W37.77 V × 11.91 A112.3 W94%
600 W453.8 W38.05 V × 11.93 A113.3 W94%
605 W457 W38.24 V × 11.95 A114 W94%
610 W461 W38.52 V × 11.97 A115 W94%
615 W464.5 W38.71 V × 12 A115.9 W94%
620 W468.3 W38.9 V × 12.04 A116.9 W94%
625 W472.2 W39.09 V × 12.08 A117.8 W94%
630 W476 W39.28 V × 12.12 A118.8 W94%
635 W479.6 W39.47 V × 12.15 A119.7 W94%
Pmax = Vmp × Imp from the CEC listing; low-light efficiency = Pmax at 200 W/m² ÷ (20% of STC Pmax).

Independent reliability testing

Kiwa PVEL Scorecard · RETC PV Module Index
5
PVEL Scorecards
Talesun named Top Performer, 2017–2025
1
RETC PV Module Index
Talesun, 2024
This exact series is not listed in published PVEL Top Performer tables. Results below are for the manufacturer.

RETC PV Module Index — Talesun

YearRecognition
2024Test Category High Achiever

Inverter compatibility & string sizing

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation · NLR PVWatts v8 · inverter datasheets · NLR SAM inverter library · CEC Grid Support Inverter List (Oct 7, 2026)
51.8 V
Voc when cold
per panel
34.1 V
Vmp when hot
per panel
11
Max panels / string
max DC 600 V
2
Min panels / string
MPPT from 60 V
Defaults come from NLR TMY weather (coldest hour, hottest modeled cell). Code calculations (NEC 690.7) use the ASHRAE extreme annual minimum, which is usually colder — enter it above. β is the CEC-measured coefficient; NEC 690.7 calculations use the datasheet value.

String inverters most named in SoCal permits

InverterMax DC inputMPPTWindow sourcePanels per string
Tesla 1538000-xx-y600 V60–480 Vdatasheet2–11
Solis (Ginlong) S6-EH1P10K-H-US600 V80–520 Vdatasheet3–11
Solis (Ginlong) Solis-1P7.6K-4G-US600 V100–500 Vdatasheet3–11
Qcells Q.VOLT H7.6SX498 V234–498 VCEC test window7–9

Microinverters (one per panel)

No microinverter in the reference set lists this power class in its recommended module power range.
Voltage check against the microinverter datasheets — confirm the pairing on the manufacturer’s module compatibility list. Rows appear only when the panel’s power is inside the microinverter’s recommended module power range.
SolarEdge and other optimizer-based systems size strings by the optimizer rules — use the manufacturer’s designer. Reference inverters: most named in SoCal permits since Oct 2024.

Expected production in Southern California

NLR PVWatts v8 · Cali-Graf calculation
CitykWh / kW / yrkWh / panel / yrkWh / system / yrSun, kWh/m²/day
Los Angeles1,6761,02211,2466.08
Palmdale1,8351,11912,3136.69
Chula Vista1,6961,03511,3806.11
Huntington Beach1,6431,00211,0255.89
Riverside1,6961,03511,3806.21
Santa Clarita1,7241,05211,5686.28
734Jan735Feb943Mar1,041Apr1,029May1,093Jun1,151Jul1,165Aug1,019Sep898Oct772Nov668DeckWh per month · Los Angeles
Estimate for comparison, not a quote: shading, roof orientation and local losses change real output. Roof mount, 20° tilt, south, 14% system losses.

Compare with similar 610 W panels

CEC PV Module List (Oct 7, 2026) · Kiwa PVEL Scorecard · Canadian Solar datasheet
PanelPmaxEfficiencyγ Pmax (CEC)Voc, VIsc, APVEL (product / brand)
Talesun TM3F66M 610610 W≈22.8%−0.2914915.86brand 5×
Phono Solar PS610M8GFH-24/TNH610 W≈23.8%−0.29353.814.02product 2024, 2025
ZNShine Solar ZXM7-UHLDD144-610/N610 W≈23.8%−0.28152.714.66product 2024, 2025, 2026
Canadian Solar CS6.2-66TB-610HP610 W≈22.6%−0.2824815.97brand 5× (2020–2026)
Same fields from the same sources for every row; ≈ efficiency is calculated from the listed area. Comparable series: other brands, same product group, power range covering this class.

About Talesun

CEC PV Module List (Oct 7, 2026) · Kiwa PVEL Scorecard · RETC PV Module Index · building permits

Other series by SoCal permits

TM7G54M · 1TM3F48MTM3G48MTM3G66MTM7F54MTM7F72M

Questions & answers

How efficient is the Talesun TM3F66M 610?

Calculated from the panel area (2.68 m²): about 22.8% for the 610 W class. 610 W over 2.68 m² equals about 228 W per square meter.

How much energy does one panel produce in Los Angeles or Palmdale?

PVWatts v8 with typical-year weather gives about 1,022 kWh per year per 610 W panel in Los Angeles and about 1,119 kWh in Palmdale (20° roof, facing south, 14% system losses).

How much power does it lose on a hot roof?

With γ = −0.291 %/°C, at a 77 °C cell temperature (hottest modeled hour in Palmdale) output is about 15.1% below the STC rating.

How many panels fit on one string?

With the Tesla 1538000-xx-y (max DC 600 V, MPPT from 60 V, datasheet) in Los Angeles the calculator gives 2–11 panels per string (Voc at 2 °C = 51.8 V, Vmp at 74 °C cell = 34.1 V). Final design must follow the inverter manual and NEC 690.7.

Has this panel been reliability-tested?

This exact series is not in published PVEL Top Performer tables; Talesun was named a Top Performer in 5 Scorecards (2017–2025).

Sources

  1. California Energy Commission — Solar Equipment Lists, PV Module List, Inverter List (snapshot Oct 7, 2026).
  2. Canadian Solar — datasheet TOPBiHiKu6 Anti-Hail N-type Bifacial TOPCon Technology.
  3. Kiwa PVEL — PV Module Reliability Scorecard, Top Performer lists 2017–2025.
  4. RETC — PV Module Index report.
  5. NLR (formerly NREL) — System Advisor Model CEC inverter library (version 2026.7.3).
  6. NLR (formerly NREL) — PVWatts v8, NSRDB PSM v3 typical-year weather for Los Angeles, Palmdale, Chula Vista, Huntington Beach, Riverside, Santa Clarita.
  7. Inverter datasheets — Solis (Ginlong), Tesla (manufacturer documents).
  8. Building permits — Southern California permit portals. Equipment matched from permit descriptions.
  9. Cali-Graf calculations — formulas and inputs are shown next to each calculated value (efficiency from area, temperature-corrected voltages, string sizing, energy estimates).