CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation
CEC listing test
Pmax coefficient γ
−0.409 %/°C
Voc coefficient β
−0.337 %/°C
Isc coefficient α
+0.045 %/°C
Operating cell temperature
NOCT 45.3 °C
Vmp coefficient ≈ γ − α (CEC); used only for the hot-roof voltage estimate.
Away from lab conditions — CEC listing test points
Class
Pmax at NOCT
Vmp × Imp at NOCT
Pmax at 200 W/m²
Low-light efficiency vs STC
395 W
287.2 W
37.39 V × 7.68 A
74.3 W
94%
400 W
290.8 W
37.67 V × 7.72 A
75.2 W
94%
405 W
294.4 W
37.94 V × 7.76 A
76.2 W
94%
410 W
298 W
38.22 V × 7.8 A
77.1 W
94%
415 W
301.7 W
38.5 V × 7.84 A
78.1 W
94%
420 W
305.4 W
38.77 V × 7.88 A
79 W
94%
Pmax = Vmp × Imp from the CEC listing; low-light efficiency = Pmax at 200 W/m² ÷ (20% of STC Pmax).
Certifications
CEC PV Module List (Oct 7, 2026)
UL 61730IEC 61215
UL 61730CEC listing
IEC 61215design qualification on file with CEC · May 27, 2020
Independent reliability testing
Kiwa PVEL Scorecard · RETC PV Module Index
2021, 2022
PVEL Top Performer
this series
5
Tests passed as Top Performer
DH, LID+LETID, MSS, PID, TC
5
PVEL Scorecards
Talesun named Top Performer, 2017–2025
1
RETC PV Module Index
Talesun, 2024
PVEL Top Performer tests
Year
Product
Tests
2021
TD6G72M-xxx
DHLID+LETIDPID
2022
TD6G72M-xxx
DHLID+LETIDMSSPIDTC
Tested bill of materials
Cell technology (tested BOM)p-type PERC
Module design (tested BOM)Bifacial - glass//glass
Power class range tested355-400W
Details describe the tested sample, not every module of the series.
RETC PV Module Index — Talesun
Year
Recognition
2024
Test Category High Achiever
Inverter compatibility & string sizing
CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation · NLR PVWatts v8 · inverter datasheets · NLR SAM inverter library · CEC Grid Support Inverter List (Oct 7, 2026)
52.9 V
Voc when cold
per panel
32 V
Vmp when hot
per panel
11
Max panels / string
max DC 600 V
2
Min panels / string
MPPT from 60 V
Defaults come from NLR TMY weather (coldest hour, hottest modeled cell). Code calculations (NEC 690.7) use the ASHRAE extreme annual minimum, which is usually colder — enter it above. β is the CEC-measured coefficient; NEC 690.7 calculations use the datasheet value.
String inverters most named in SoCal permits
Inverter
Max DC input
MPPT
Window source
Panels per string
Tesla 1538000-xx-y
600 V
60–480 V
datasheet
2–11
Solis (Ginlong) S6-EH1P10K-H-US
600 V
80–520 V
datasheet
3–11
Solis (Ginlong) Solis-1P7.6K-4G-US
600 V
100–500 V
datasheet
4–11
Qcells Q.VOLT H7.6SX
498 V
234–498 V
CEC test window
8–9
Microinverters (one per panel)
Microinverter
Recommended module power
Max DC input
MPPT
Voc cold / Vmp hot
Check
DC/AC
Enphase IQ8PLUS-72-2-US
235–440 W
60 V
29–45 V
52.9 / 32 V
✓ Within range
1.4
Enphase IQ8X-80-M-US
320–540 W
79.5 V
43–60 V
52.9 / 32 V
✗ Not a match: module voltage below MPPT range
1.07
APsystems (Alt Power System) DS3-L
265–570 W
60 V
28–45 V
52.9 / 32 V
✓ Within range
0.52
Enphase IQ8M-72-2-US
260–460 W
60 V
30–45 V
52.9 / 32 V
✓ Within range
1.25
Enphase IQ8A-72-2-US
295–500 W
60 V
32–45 V
52.9 / 32 V
⚠ Works; below MPPT at peak heat
1.16
Voltage check against the microinverter datasheets — confirm the pairing on the manufacturer’s module compatibility list. Rows appear only when the panel’s power is inside the microinverter’s recommended module power range.
SolarEdge and other optimizer-based systems size strings by the optimizer rules — use the manufacturer’s designer. Reference inverters: most named in SoCal permits since Oct 2024.
Expected production in Southern California
NLR PVWatts v8 · Cali-Graf calculation
City
kWh / kW / yr
kWh / panel / yr
kWh / system / yr
Sun, kWh/m²/day
Los Angeles
1,676
679
11,539
6.08
Palmdale
1,835
743
12,634
6.69
Chula Vista
1,696
687
11,677
6.11
Huntington Beach
1,643
665
11,312
5.89
Riverside
1,696
687
11,677
6.21
Santa Clarita
1,724
698
11,870
6.28
Estimate for comparison, not a quote: shading, roof orientation and local losses change real output. Roof mount, 20° tilt, south, 14% system losses.
Compare with similar 405 W panels
CEC PV Module List (Oct 7, 2026) · Qcells datasheet · Kiwa PVEL Scorecard · building permits
Panel
Pmax
Efficiency
γ Pmax (CEC)
Voc, V
Isc, A
PVEL (product / brand)
SoCal permits (series)
Talesun TD6G72M 405
405 W
≈19.8%
−0.409
49.1
10.37
product 2021, 2022
—
Qcells Q.PEAK DUO BLK ML-G10+ 405
405 W
≥20.6%
−0.362
45.34
11.17
product 2022, 2023
221
JA Solar JAM54S31-405/MR
405 W
≈21.3%
−0.329
37.23
13.87
product 2023, 2024
152
REC Group REC405AA Pure
405 W
≈22.6%
−0.256
48.9
10.3
brand 9× (2016–2025)
66
Same fields from the same sources for every row; ≈ efficiency is calculated from the listed area. Comparable series: other brands, same product group, power range covering this class.
About Talesun
CEC PV Module List (Oct 7, 2026) · Kiwa PVEL Scorecard · RETC PV Module Index · building permits
ManufacturerTalesun
Listed in CEC asSuzhou Talesun Solar Technologies Co., Ltd.
PVEL Top Performer (manufacturer)5 Scorecards (2017–2025)
RETC PV Module Index2024
Current panel series in CEC list34
Other series by SoCal permits
TM7G54M · 1TM3F48MTM3F66MTM3G48MTM3G66MTM7F54M
Questions & answers
How efficient is the Talesun TD6G72M 405?
Calculated from the panel area (2.05 m²): about 19.8% for the 405 W class. 405 W over 2.05 m² equals about 197 W per square meter.
How much energy does one panel produce in Los Angeles or Palmdale?
PVWatts v8 with typical-year weather gives about 679 kWh per year per 405 W panel in Los Angeles and about 743 kWh in Palmdale (20° roof, facing south, 14% system losses).
How much power does it lose on a hot roof?
With γ = −0.409 %/°C, at a 77 °C cell temperature (hottest modeled hour in Palmdale) output is about 21.2% below the STC rating.
How many panels fit on one string?
With the Tesla 1538000-xx-y (max DC 600 V, MPPT from 60 V, datasheet) in Los Angeles the calculator gives 2–11 panels per string (Voc at 2 °C = 52.9 V, Vmp at 74 °C cell = 32 V). Final design must follow the inverter manual and NEC 690.7.
Does it work with Enphase IQ8PLUS-72-2-US microinverters?
Voltage check against the Enphase datasheet: Voc when cold 52.9 V vs max input 60 V; Vmp when hot 32 V vs MPPT low 29 V; recommended module power 235–440 W. Confirm on the microinverter maker’s compatibility list.
Is it bifacial?
Yes. Rear gain depends on mounting height and ground reflectance.
Has this panel been reliability-tested?
TD6G72M-xxx was a PVEL Top Performer in 2021, 2022 (DH, LID+LETID, MSS, PID, TC).
Sources
California Energy Commission — Solar Equipment Lists, PV Module List, Inverter List (snapshot Oct 7, 2026).
Qcells — manufacturer datasheet “Q.PEAK DUO BLK ML-G10+ ENDURING HIGH PERFORMANCE”.
NLR (formerly NREL) — System Advisor Model CEC module and inverter libraries (version 2026.7.3).
NLR (formerly NREL) — PVWatts v8, NSRDB PSM v3 typical-year weather for Los Angeles, Palmdale, Chula Vista, Huntington Beach, Riverside, Santa Clarita.
Inverter datasheets — APsystems (Alt Power System), Enphase, Solis (Ginlong), Tesla (manufacturer documents).
Building permits — Southern California permit portals. Equipment matched from permit descriptions.
Cali-Graf calculations — formulas and inputs are shown next to each calculated value (efficiency from area, temperature-corrected voltages, string sizing, energy estimates).
Get your free estimate
Three fields, and Cali Energy calls back within 30 minutes during business hours.
Thanks!
We got your request and will call back within 30 minutes during business hours.