Building-integrated solar panelSunTegra

SunTegra STS-110M-B4U

24 cells, shingle. Power classes 110–114 W in the CEC list.

CEC listed · Oct 1, 2018UL 1703Building-integrated (BIPV)
Power class
  • Power (STC)110 WCEC nameplate
  • Efficiency≈16.7%calculated from area
  • %/°C Pmax−0.404CEC listing test
  • PTC / STC86.6%PTC 95 W (CEC)

Power classes

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation · 2 models
ModelPmaxVoc, VIsc, AVmp, VImp, AEfficiencyPTCCEC listed
STS-110M-B4U110 W15.469.4112.728.66≈16.7%95 WOct 1, 2018
STS-114M-B4U114 W15.529.6812.788.92≈17.3%99 WJan 21, 2020
≈ efficiency = Pmax ÷ CEC-listed area 0.66 m².

Build & dimensions

CEC PV Module List (Oct 7, 2026)

Heat & cold behaviour

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation
CEC listing test
Pmax coefficient γ−0.404 %/°C
Voc coefficient β−0.291 %/°C
Isc coefficient α+0.038 %/°C
Vmp coefficient−0.396 %/°C
Operating cell temperatureNOCT 57.3 °C

Away from lab conditions — CEC listing test points

ClassPmax at NOCTVmp × Imp at NOCTPmax at 200 W/m²Low-light efficiency vs STC
110 W76.1 W11.09 V × 6.86 A21.2 W97%
114 W78.8 W11.15 V × 7.07 A22 W96%
Pmax = Vmp × Imp from the CEC listing; low-light efficiency = Pmax at 200 W/m² ÷ (20% of STC Pmax).

Inverter compatibility & string sizing

CEC PV Module List (Oct 7, 2026) · NLR PVWatts v8
16.5 V
Voc when cold
per panel
10.3 V
Vmp when hot
per panel
Defaults come from NLR TMY weather (coldest hour, hottest modeled cell). Code calculations (NEC 690.7) use the ASHRAE extreme annual minimum, which is usually colder — enter it above. β is the CEC-measured coefficient; NEC 690.7 calculations use the datasheet value.
Integrated roof products are wired per the manufacturer’s system design.
SolarEdge and other optimizer-based systems size strings by the optimizer rules — use the manufacturer’s designer. Reference inverters: most named in SoCal permits since Oct 2024.

Expected production in Southern California

NLR PVWatts v8 · Cali-Graf calculation
CitykWh / kW / yrkWh / panel / yrkWh / system / yrSun, kWh/m²/day
Los Angeles1,6761845,5316.08
Palmdale1,8352026,0566.69
Chula Vista1,6961875,5976.11
Huntington Beach1,6431815,4225.89
Riverside1,6961875,5976.21
Santa Clarita1,7241905,6896.28
361Jan361Feb464Mar512Apr506May538Jun566Jul573Aug501Sep442Oct380Nov329DeckWh per month · Los Angeles
PVWatts models a standard roof-mounted module; integrated roof products are not modeled separately.
Estimate for comparison, not a quote: shading, roof orientation and local losses change real output. Roof mount, 20° tilt, south, 14% system losses.

Questions & answers

How efficient is the SunTegra STS-110M-B4U?

Calculated from the panel area (0.66 m²): about 16.7% for the 110 W class. 110 W over 0.66 m² equals about 167 W per square meter.

How much energy does one panel produce in Los Angeles or Palmdale?

PVWatts v8 with typical-year weather gives about 184 kWh per year per 110 W panel in Los Angeles and about 202 kWh in Palmdale (20° roof, facing south, 14% system losses).

How much power does it lose on a hot roof?

With γ = −0.404 %/°C, at a 77 °C cell temperature (hottest modeled hour in Palmdale) output is about 20.9% below the STC rating.