Cali-GrafCali-Graf
Solar panelSuntech

Suntech STP330S-A60/Wfhb

120 half-cut cells. Power classes 295–340 W in the CEC list.

CEC listed · Oct 12, 2020UL 61730Seen in 1 SoCal permit
Power class
  • Power (STC)330 WCEC nameplate
  • Efficiency≈19.5%calculated from area
  • %/°C Pmax−0.379CEC listing test
  • PTC / STC93.3%PTC 308 W (CEC)

Power classes

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation · 10 models
ModelPmaxVoc, VIsc, AVmp, VImp, AEfficiencyPTCCEC listed
STP295S-A60/Wfhb295 W39.309.4533.308.86≈17.9%273 WOct 12, 2020
STP300S-A60/Wfhb300 W39.509.5533.508.96≈18.2%277 WOct 12, 2020
STP305S-A60/Wfhb305 W39.709.6533.709.06≈18.5%282 WOct 12, 2020
STP310S-A60/Wfhb310 W39.809.8733.109.37≈18.3%289 WOct 12, 2020
STP315S-A60/Wfhb315 W40.109.9533.409.44≈18.6%294 WOct 12, 2020
STP320S-A60/Wfhb320 W40.4010.0133.609.52≈18.9%298 WOct 12, 2020
STP325S-A60/Wfhb325 W40.7010.0833.909.59≈19.2%303 WOct 12, 2020
STP330S-A60/Wfhb330 W41.0010.1634.209.66≈19.5%308 WOct 12, 2020
STP335S-A60/Wfhb335 W41.2010.3534.409.75≈19.8%313 WOct 12, 2020
STP340S-A60/Wfhb340 W41.4010.4434.609.82≈20.1%318 WOct 12, 2020
≈ efficiency = Pmax ÷ CEC-listed area 1.65 m².

Build & dimensions

CEC PV Module List (Oct 7, 2026)

Heat & cold behaviour

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation
CEC listing test
Pmax coefficient γ−0.379 %/°C
Voc coefficient β−0.319 %/°C
Isc coefficient α+0.045 %/°C
Operating cell temperatureNOCT 43.1 °C
Vmp coefficient ≈ γ − α (CEC); used only for the hot-roof voltage estimate.

Away from lab conditions — CEC listing test points

ClassPmax at NOCTVmp × Imp at NOCTPmax at 200 W/m²Low-light efficiency vs STC
295 W222.4 W30.52 V × 7.29 A56 W95%
300 W226.3 W30.71 V × 7.37 A57 W95%
305 W230.2 W30.89 V × 7.45 A58 W95%
310 W234.3 W31.23 V × 7.5 A58.6 W94%
315 W238.2 W31.51 V × 7.56 A59.6 W95%
320 W241.6 W31.7 V × 7.62 A60.4 W94%
325 W245.6 W31.98 V × 7.68 A61.4 W94%
330 W249.5 W32.27 V × 7.73 A62.4 W95%
335 W253.3 W32.45 V × 7.81 A63.4 W95%
340 W256.6 W32.64 V × 7.86 A64.2 W94%
Pmax = Vmp × Imp from the CEC listing; low-light efficiency = Pmax at 200 W/m² ÷ (20% of STC Pmax).

Independent reliability testing

Kiwa PVEL Scorecard
6
PVEL Scorecards
Suntech named Top Performer, 2014–2024
This exact series is not listed in published PVEL Top Performer tables. Results below are for the manufacturer.

Inverter compatibility & string sizing

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation · NLR PVWatts v8 · inverter datasheets · NLR SAM inverter library · CEC Grid Support Inverter List (Oct 7, 2026)
44 V
Voc when cold
per panel
27.1 V
Vmp when hot
per panel
13
Max panels / string
max DC 600 V
3
Min panels / string
MPPT from 60 V
Defaults come from NLR TMY weather (coldest hour, hottest modeled cell). Code calculations (NEC 690.7) use the ASHRAE extreme annual minimum, which is usually colder — enter it above. β is the CEC-measured coefficient; NEC 690.7 calculations use the datasheet value.

String inverters most named in SoCal permits

InverterMax DC inputMPPTWindow sourcePanels per string
Tesla 1538000-xx-y600 V60–480 Vdatasheet3–13
Solis (Ginlong) S6-EH1P10K-H-US600 V80–520 Vdatasheet3–13
Solis (Ginlong) Solis-1P7.6K-4G-US600 V100–500 Vdatasheet4–13
Qcells Q.VOLT H7.6SX498 V234–498 VCEC test window9–11

Microinverters (one per panel)

MicroinverterRecommended module powerMax DC inputMPPTVoc cold / Vmp hotCheckDC/AC
Enphase IQ8PLUS-72-2-US235–440 W60 V29–45 V44 / 27.1 V⚠ Works; below MPPT at peak heat1.14
Enphase IQ8X-80-M-US320–540 W79.5 V43–60 V44 / 27.1 V✗ Not a match: module voltage below MPPT range0.87
APsystems (Alt Power System) DS3-L265–570 W60 V28–45 V44 / 27.1 V⚠ Works; below MPPT at peak heat0.42
Enphase IQ8M-72-2-US260–460 W60 V30–45 V44 / 27.1 V⚠ Works; below MPPT at peak heat1.02
Enphase IQ8A-72-2-US295–500 W60 V32–45 V44 / 27.1 V⚠ Works; below MPPT at peak heat0.95
Voltage check against the microinverter datasheets — confirm the pairing on the manufacturer’s module compatibility list. Rows appear only when the panel’s power is inside the microinverter’s recommended module power range.
SolarEdge and other optimizer-based systems size strings by the optimizer rules — use the manufacturer’s designer. Reference inverters: most named in SoCal permits since Oct 2024.

Expected production in Southern California

NLR PVWatts v8 · Cali-Graf calculation
CitykWh / kW / yrkWh / panel / yrkWh / system / yrSun, kWh/m²/day
Los Angeles1,67655311,6156.08
Palmdale1,83560612,7176.69
Chula Vista1,69656011,7536.11
Huntington Beach1,64354211,3865.89
Riverside1,69656011,7536.21
Santa Clarita1,72456911,9476.28
758Jan759Feb974Mar1,076Apr1,062May1,129Jun1,189Jul1,203Aug1,052Sep928Oct798Nov690DeckWh per month · Los Angeles
Estimate for comparison, not a quote: shading, roof orientation and local losses change real output. Roof mount, 20° tilt, south, 14% system losses.

Compare with similar 330 W panels

CEC PV Module List (Oct 7, 2026) · Kiwa PVEL Scorecard · datasheets · building permits
PanelPmaxEfficiencyγ Pmax (CEC)Voc, VIsc, APVEL (product / brand)SoCal permits (series)
Suntech STP330S-A60/Wfhb330 W≈19.5%−0.3794110.16brand 6×1
LONGi LR4-60HPB-335M335 W≈18.5%−0.33739.910.76product 2021, 2022193
JinkoSolar JKM330M-60HBL330 W≈19.6%−0.40640.610.61brand 12× (2014–2026)45
Qcells Q.PEAK DUO-G8+ 330330 W≈18.4%−0.34339.7110.52product 202220
Same fields from the same sources for every row; ≈ efficiency is calculated from the listed area. Comparable series: other brands, same product group, power range covering this class.

Questions & answers

How efficient is the Suntech STP330S-A60/Wfhb?

Calculated from the panel area (1.69 m²): about 19.5% for the 330 W class. 330 W over 1.69 m² equals about 195 W per square meter.

How much energy does one panel produce in Los Angeles or Palmdale?

PVWatts v8 with typical-year weather gives about 553 kWh per year per 330 W panel in Los Angeles and about 606 kWh in Palmdale (20° roof, facing south, 14% system losses).

How much power does it lose on a hot roof?

With γ = −0.379 %/°C, at a 77 °C cell temperature (hottest modeled hour in Palmdale) output is about 19.6% below the STC rating.

How many panels fit on one string?

With the Tesla 1538000-xx-y (max DC 600 V, MPPT from 60 V, datasheet) in Los Angeles the calculator gives 3–13 panels per string (Voc at 2 °C = 44 V, Vmp at 74 °C cell = 27.1 V). Final design must follow the inverter manual and NEC 690.7.

Has this panel been reliability-tested?

This exact series is not in published PVEL Top Performer tables; Suntech was named a Top Performer in 6 Scorecards (2014–2024).

Sources

  1. California Energy Commission — Solar Equipment Lists, PV Module List, Inverter List (snapshot Oct 7, 2026).
  2. JinkoSolar — datasheet THE MOST DEPENDABLE SOLAR BRAND.
  3. JinkoSolar — manufacturer datasheet “Eagle HC 60M G2 315-335 Watt MONO PERC HALF CELL MODULE”.
  4. Qcells — manufacturer datasheet “Q.PEAK DUO-G8+ 345-360 EN ENDURING HIGH”.
  5. Kiwa PVEL — PV Module Reliability Scorecard, Top Performer lists 2014–2024.
  6. NLR (formerly NREL) — System Advisor Model CEC inverter library (version 2026.7.3).
  7. NLR (formerly NREL) — PVWatts v8, NSRDB PSM v3 typical-year weather for Los Angeles, Palmdale, Chula Vista, Huntington Beach, Riverside, Santa Clarita.
  8. Inverter datasheets — APsystems (Alt Power System), Enphase, Solis (Ginlong), Tesla (manufacturer documents).
  9. Building permits — Los Angeles County Public Works (EPIC-LA, unincorporated areas) (Jul 2021). Equipment matched from permit descriptions by model number.
  10. Cali-Graf calculations — formulas and inputs are shown next to each calculated value (efficiency from area, temperature-corrected voltages, string sizing, energy estimates).