72 cells. Power classes 355–400 W in the CEC list.
| Model | Pmax | Voc, V | Isc, A | Vmp, V | Imp, A | Efficiency | PTC | CEC listed |
|---|---|---|---|---|---|---|---|---|
| STP355S-A24U/Vfw | 355 W | 47.40 | 9.65 | 38.30 | 9.27 | ≈18.2% | 328 W | Oct 12, 2020 |
| STP360S-A24U/Vfw | 360 W | 47.60 | 9.74 | 38.50 | 9.36 | ≈18.5% | 333 W | Oct 12, 2020 |
| STP365S-A24U/Vfw | 365 W | 47.80 | 9.82 | 38.70 | 9.44 | ≈18.7% | 338 W | Oct 12, 2020 |
| STP370S-A24U/Vfw | 370 W | 48.00 | 9.90 | 38.90 | 9.52 | ≈19.0% | 343 W | Oct 12, 2020 |
| STP375S-A24U/Vfw | 375 W | 48.20 | 9.97 | 39.10 | 9.60 | ≈19.2% | 348 W | Oct 12, 2020 |
| STP380S-A24U/Vfw | 380 W | 48.40 | 10.04 | 39.30 | 9.67 | ≈19.5% | 352 W | Oct 12, 2020 |
| STP385S-A24U/Vfw | 385 W | 48.60 | 10.11 | 39.50 | 9.75 | ≈19.7% | 357 W | Oct 12, 2020 |
| STP390S-A24U/Vfw | 390 W | 48.80 | 10.18 | 39.70 | 9.83 | ≈20.0% | 362 W | Oct 12, 2020 |
| STP395S-A24U/Vfw | 395 W | 49.00 | 10.25 | 39.90 | 9.90 | ≈20.3% | 366 W | Oct 12, 2020 |
| STP400S-A24U/Vfw | 400 W | 49.20 | 10.33 | 40.10 | 9.98 | ≈20.5% | 371 W | Oct 12, 2020 |
| CEC listing test | |
|---|---|
| Pmax coefficient γ | −0.355 %/°C |
| Voc coefficient β | −0.265 %/°C |
| Isc coefficient α | +0.041 %/°C |
| Operating cell temperature | NOCT 46.1 °C |
| Class | Pmax at NOCT | Vmp × Imp at NOCT | Pmax at 200 W/m² | Low-light efficiency vs STC |
|---|---|---|---|---|
| 355 W | 267.5 W | 36.53 V × 7.32 A | 70.4 W | 99% |
| 360 W | 271.5 W | 36.72 V × 7.39 A | 71.4 W | 99% |
| 365 W | 275.2 W | 36.91 V × 7.46 A | 72.4 W | 99% |
| 370 W | 279 W | 37.1 V × 7.52 A | 73.4 W | 99% |
| 375 W | 282.8 W | 37.29 V × 7.58 A | 74.4 W | 99% |
| 380 W | 286.3 W | 37.48 V × 7.64 A | 75.3 W | 99% |
| 385 W | 290.2 W | 37.67 V × 7.7 A | 76.3 W | 99% |
| 390 W | 294 W | 37.86 V × 7.77 A | 77.3 W | 99% |
| 395 W | 297.6 W | 38.05 V × 7.82 A | 78.3 W | 99% |
| 400 W | 301.5 W | 38.24 V × 7.88 A | 79.3 W | 99% |
| Inverter | Max DC input | MPPT | Window source | Panels per string |
|---|---|---|---|---|
| Tesla 1538000-xx-y | 600 V | 60–480 V | datasheet | 2–11 |
| Solis (Ginlong) S6-EH1P10K-H-US | 600 V | 80–520 V | datasheet | 3–11 |
| Solis (Ginlong) Solis-1P7.6K-4G-US | 600 V | 100–500 V | datasheet | 4–11 |
| Qcells Q.VOLT H7.6SX | 498 V | 234–498 V | CEC test window | 8–9 |
| Microinverter | Recommended module power | Max DC input | MPPT | Voc cold / Vmp hot | Check | DC/AC |
|---|---|---|---|---|---|---|
| Enphase IQ8PLUS-72-2-US | 235–440 W | 60 V | 29–45 V | 51.1 / 31.5 V | ✓ Within range | 1.29 |
| Enphase IQ8X-80-M-US | 320–540 W | 79.5 V | 43–60 V | 51.1 / 31.5 V | ✗ Not a match: module voltage below MPPT range | 0.99 |
| APsystems (Alt Power System) DS3-L | 265–570 W | 60 V | 28–45 V | 51.1 / 31.5 V | ✓ Within range | 0.48 |
| Enphase IQ8M-72-2-US | 260–460 W | 60 V | 30–45 V | 51.1 / 31.5 V | ✓ Within range | 1.15 |
| Enphase IQ8A-72-2-US | 295–500 W | 60 V | 32–45 V | 51.1 / 31.5 V | ⚠ Works; below MPPT at peak heat | 1.07 |
| City | kWh / kW / yr | kWh / panel / yr | kWh / system / yr | Sun, kWh/m²/day |
|---|---|---|---|---|
| Los Angeles | 1,676 | 628 | 11,942 | 6.08 |
| Palmdale | 1,835 | 688 | 13,074 | 6.69 |
| Chula Vista | 1,696 | 636 | 12,084 | 6.11 |
| Huntington Beach | 1,643 | 616 | 11,706 | 5.89 |
| Riverside | 1,696 | 636 | 12,084 | 6.21 |
| Santa Clarita | 1,724 | 646 | 12,284 | 6.28 |
| Panel | Pmax | Efficiency | γ Pmax (CEC) | Voc, V | Isc, A | PVEL (product / brand) | SoCal permits (series) |
|---|---|---|---|---|---|---|---|
| Suntech STP375S-A24U/Vfw | 375 W | ≈19.2% | −0.355 | 48.2 | 9.97 | brand 6× | — |
| Qcells Q.PEAK DUO BLK ML-G10+ 380 | 380 W | ≈19.4% | −0.362 | 45.16 | 11.01 | product 2022, 2023 | 221 |
| LONGi LR4-60HPB-370M | 370 W | ≈20.9% | −0.339 | 41.2 | 11.5 | product 2021, 2022 | 193 |
| REC Group REC380AA Pure | 380 W | ≈21.2% | −0.256 | 48.4 | 10.17 | brand 9× (2016–2025) | 66 |
Calculated from the panel area (1.95 m²): about 19.2% for the 375 W class. 375 W over 1.95 m² equals about 192 W per square meter.
PVWatts v8 with typical-year weather gives about 628 kWh per year per 375 W panel in Los Angeles and about 688 kWh in Palmdale (20° roof, facing south, 14% system losses).
With γ = −0.355 %/°C, at a 77 °C cell temperature (hottest modeled hour in Palmdale) output is about 18.4% below the STC rating.
With the Tesla 1538000-xx-y (max DC 600 V, MPPT from 60 V, datasheet) in Los Angeles the calculator gives 2–11 panels per string (Voc at 2 °C = 51.1 V, Vmp at 74 °C cell = 31.5 V). Final design must follow the inverter manual and NEC 690.7.
Voltage check against the Enphase datasheet: Voc when cold 51.1 V vs max input 60 V; Vmp when hot 31.5 V vs MPPT low 29 V; recommended module power 235–440 W. Confirm on the microinverter maker’s compatibility list.
This exact series is not in published PVEL Top Performer tables; Suntech was named a Top Performer in 6 Scorecards (2014–2024).