Cali-GrafCali-Graf
Building-integrated solar panelSunStyle

SunStyle M110 870

24 cells, PERC. 110 W in the CEC list.

CEC listed · Dec 11, 2023UL 61730Building-integrated (BIPV)
  • Power (STC)110 WCEC nameplate
  • Efficiency≈14.5%calculated from area
  • %/°C Pmax−0.401CEC listing test
  • PTC / STC89.3%PTC 98 W (CEC)

Electrical ratings (STC)

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation
ModelPmaxVoc, VIsc, AVmp, VImp, AEfficiencyPTCCEC listed
M110 870110 W16.109.2013.108.40≈14.5%98 WDec 11, 2023
≈ efficiency = Pmax ÷ CEC-listed area 0.76 m².

Heat & cold behaviour

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation
CEC listing test
Pmax coefficient γ−0.401 %/°C
Voc coefficient β−0.281 %/°C
Isc coefficient α+0.037 %/°C
Operating cell temperatureNOCT 50.2 °C
Vmp coefficient ≈ γ − α (CEC); used only for the hot-roof voltage estimate.

Away from lab conditions — CEC listing test points

ClassPmax at NOCTVmp × Imp at NOCTPmax at 200 W/m²Low-light efficiency vs STC
110 W81.6 W11.68 V × 6.99 A22.2 W101%
Pmax = Vmp × Imp from the CEC listing; low-light efficiency = Pmax at 200 W/m² ÷ (20% of STC Pmax).

Inverter compatibility & string sizing

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation · NLR PVWatts v8
17.1 V
Voc when cold
per panel
10.3 V
Vmp when hot
per panel
Defaults come from NLR TMY weather (coldest hour, hottest modeled cell). Code calculations (NEC 690.7) use the ASHRAE extreme annual minimum, which is usually colder — enter it above. β is the CEC-measured coefficient; NEC 690.7 calculations use the datasheet value.
Integrated roof products are wired per the manufacturer’s system design.
SolarEdge and other optimizer-based systems size strings by the optimizer rules — use the manufacturer’s designer. Reference inverters: most named in SoCal permits since Oct 2024.

Expected production in Southern California

NLR PVWatts v8 · Cali-Graf calculation
CitykWh / kW / yrkWh / panel / yrkWh / system / yrSun, kWh/m²/day
Los Angeles1,6761845,5316.08
Palmdale1,8352026,0566.69
Chula Vista1,6961875,5976.11
Huntington Beach1,6431815,4225.89
Riverside1,6961875,5976.21
Santa Clarita1,7241905,6896.28
361Jan361Feb464Mar512Apr506May538Jun566Jul573Aug501Sep442Oct380Nov329DeckWh per month · Los Angeles
PVWatts models a standard roof-mounted module; integrated roof products are not modeled separately.
Estimate for comparison, not a quote: shading, roof orientation and local losses change real output. Roof mount, 20° tilt, south, 14% system losses.

Questions & answers

How efficient is the SunStyle M110 870?

Calculated from the panel area (0.76 m²): about 14.5% for the 110 W class. 110 W over 0.76 m² equals about 145 W per square meter.

How much energy does one panel produce in Los Angeles or Palmdale?

PVWatts v8 with typical-year weather gives about 184 kWh per year per 110 W panel in Los Angeles and about 202 kWh in Palmdale (20° roof, facing south, 14% system losses).

How much power does it lose on a hot roof?

With γ = −0.401 %/°C, at a 77 °C cell temperature (hottest modeled hour in Palmdale) output is about 20.8% below the STC rating.

Sources

  1. California Energy Commission — Solar Equipment Lists, PV Module List (snapshot Oct 7, 2026).
  2. NLR (formerly NREL) — PVWatts v8, NSRDB PSM v3 typical-year weather for Los Angeles, Palmdale, Chula Vista, Huntington Beach, Riverside, Santa Clarita.
  3. Cali-Graf calculations — formulas and inputs are shown next to each calculated value (efficiency from area, temperature-corrected voltages, string sizing, energy estimates).