144 half-cut cells, bifacial. Power classes 530–560 W in the CEC list.
| Model | Pmax | Voc, V | Isc, A | Vmp, V | Imp, A | Efficiency | PTC | CEC listed |
|---|---|---|---|---|---|---|---|---|
| SST-M144(HCBF)-530W | 530 W | 49.20 | 13.60 | 41.50 | 12.79 | ≈20.7% | 490 W | Sep 1, 2023 |
| SST-M144(HCBF)-535W | 535 W | 49.50 | 13.65 | 41.70 | 12.83 | ≈20.9% | 495 W | Sep 1, 2023 |
| SST-M144(HCBF)-540W | 540 W | 49.80 | 13.70 | 42.00 | 12.86 | ≈21.1% | 500 W | Sep 1, 2023 |
| SST-M144(HCBF)-545W | 545 W | 50.10 | 13.75 | 42.30 | 12.90 | ≈21.3% | 505 W | Sep 1, 2023 |
| SST-M144(HCBF)-550W | 550 W | 50.40 | 13.80 | 42.50 | 12.95 | ≈21.5% | 510 W | Sep 1, 2023 |
| SST-M144(HCBF)-555W | 555 W | 50.70 | 13.85 | 42.80 | 12.99 | ≈21.7% | 514 W | Sep 1, 2023 |
| SST-M144(HCBF)-560W | 560 W | 51.00 | 13.90 | 43.00 | 13.04 | ≈21.9% | 519 W | Sep 1, 2023 |
| CEC listing test | |
|---|---|
| Pmax coefficient γ | −0.385 %/°C |
| Voc coefficient β | −0.262 %/°C |
| Isc coefficient α | +0.020 %/°C |
| Operating cell temperature | NOCT 45.3 °C |
| Class | Pmax at NOCT | Vmp × Imp at NOCT | Pmax at 200 W/m² | Low-light efficiency vs STC |
|---|---|---|---|---|
| 530 W | 386.7 W | 37.8 V × 10.23 A | 98.6 W | 93% |
| 535 W | 390.3 W | 38 V × 10.27 A | 99.2 W | 93% |
| 540 W | 394.1 W | 38.3 V × 10.29 A | 100.2 W | 93% |
| 545 W | 397.3 W | 38.5 V × 10.32 A | 101.2 W | 93% |
| 550 W | 400.9 W | 38.7 V × 10.36 A | 102.2 W | 93% |
| 555 W | 405.2 W | 39 V × 10.39 A | 103.3 W | 93% |
| 560 W | 408.9 W | 39.2 V × 10.43 A | 104.2 W | 93% |
| Inverter | Max DC input | MPPT | Window source | Panels per string |
|---|---|---|---|---|
| Tesla 1538000-xx-y | 600 V | 60–480 V | datasheet | 2–11 |
| Solis (Ginlong) S6-EH1P10K-H-US | 600 V | 80–520 V | datasheet | 3–11 |
| Solis (Ginlong) Solis-1P7.6K-4G-US | 600 V | 100–500 V | datasheet | 3–11 |
| Qcells Q.VOLT H7.6SX | 498 V | 234–498 V | CEC test window | 7–9 |
| Microinverter | Recommended module power | Max DC input | MPPT | Voc cold / Vmp hot | Check | DC/AC |
|---|---|---|---|---|---|---|
| APsystems (Alt Power System) DS3-L | 265–570 W | 60 V | 28–45 V | 53.1 / 33.9 V | ✓ Within range | 0.7 |
| City | kWh / kW / yr | kWh / panel / yr | kWh / system / yr | Sun, kWh/m²/day |
|---|---|---|---|---|
| Los Angeles | 1,676 | 913 | 11,874 | 6.08 |
| Palmdale | 1,835 | 1,000 | 13,001 | 6.69 |
| Chula Vista | 1,696 | 924 | 12,016 | 6.11 |
| Huntington Beach | 1,643 | 895 | 11,641 | 5.89 |
| Riverside | 1,696 | 924 | 12,016 | 6.21 |
| Santa Clarita | 1,724 | 940 | 12,215 | 6.28 |
| Panel | Pmax | Efficiency | γ Pmax (CEC) | Voc, V | Isc, A | PVEL (product / brand) | SoCal permits (series) |
|---|---|---|---|---|---|---|---|
| SunSpark Technology SST-M144(HCBF) 545 | 545 W | ≈21.3% | −0.385 | 50.1 | 13.75 | — | — |
| JA Solar JAM72D30-545/MB | 545 W | ≈21.6% | −0.330 | 49.75 | 13.93 | product 2023, 2024 | 3 |
| LONGi LR5-72HBD-545M | 545 W | ≥21.3% | −0.354 | 49.65 | 13.92 | product 2026 | 1 |
| Canadian Solar CS6W-545MB-AG | 545 W | ≈21.2% | −0.324 | 49.4 | 13.95 | product 2024 | 1 |
Calculated from the panel area (2.56 m²): about 21.3% for the 545 W class. 545 W over 2.56 m² equals about 213 W per square meter.
PVWatts v8 with typical-year weather gives about 913 kWh per year per 545 W panel in Los Angeles and about 1,000 kWh in Palmdale (20° roof, facing south, 14% system losses).
With γ = −0.385 %/°C, at a 77 °C cell temperature (hottest modeled hour in Palmdale) output is about 19.9% below the STC rating.
With the Tesla 1538000-xx-y (max DC 600 V, MPPT from 60 V, datasheet) in Los Angeles the calculator gives 2–11 panels per string (Voc at 2 °C = 53.1 V, Vmp at 74 °C cell = 33.9 V). Final design must follow the inverter manual and NEC 690.7.
Voltage check against the APsystems (Alt Power System) datasheet: Voc when cold 53.1 V vs max input 60 V; Vmp when hot 33.9 V vs MPPT low 28 V; recommended module power 265–570 W. Confirm on the microinverter maker’s compatibility list.
Yes. Rear gain depends on mounting height and ground reflectance.