132 half-cut cells, bifacial, transparent backsheet. Power classes 500–510 W in the CEC list.
| Model | Pmax | Voc, V | Isc, A | Vmp, V | Imp, A | Efficiency | PTC | CEC listed |
|---|---|---|---|---|---|---|---|---|
| SST-M132(HCBF)-500W | 500 W | 45.70 | 13.91 | 37.80 | 13.25 | ≈23.0% | 465 W | Sep 1, 2023 |
| SST-M132(HCBF)-505W | 505 W | 45.90 | 13.96 | 38.00 | 13.30 | ≈23.3% | 470 W | Sep 1, 2023 |
| SST-M132(HCBF)-510W | 510 W | 46.10 | 14.01 | 38.20 | 13.36 | ≈23.5% | 475 W | Sep 1, 2023 |
| CEC listing test | |
|---|---|
| Pmax coefficient γ | −0.370 %/°C |
| Voc coefficient β | −0.286 %/°C |
| Isc coefficient α | +0.045 %/°C |
| Operating cell temperature | NOCT 45.5 °C |
| Class | Pmax at NOCT | Vmp × Imp at NOCT | Pmax at 200 W/m² | Low-light efficiency vs STC |
|---|---|---|---|---|
| 500 W | 355.9 W | 35 V × 10.17 A | 93.4 W | 93% |
| 505 W | 360.4 W | 35.3 V × 10.21 A | 94.3 W | 93% |
| 510 W | 363.2 W | 35.4 V × 10.26 A | 95.2 W | 93% |
| Inverter | Max DC input | MPPT | Window source | Panels per string |
|---|---|---|---|---|
| Tesla 1538000-xx-y | 600 V | 60–480 V | datasheet | 2–12 |
| Solis (Ginlong) S6-EH1P10K-H-US | 600 V | 80–520 V | datasheet | 3–12 |
| Solis (Ginlong) Solis-1P7.6K-4G-US | 600 V | 100–500 V | datasheet | 4–12 |
| Qcells Q.VOLT H7.6SX | 498 V | 234–498 V | CEC test window | 8–10 |
| Microinverter | Recommended module power | Max DC input | MPPT | Voc cold / Vmp hot | Check | DC/AC |
|---|---|---|---|---|---|---|
| Enphase IQ8X-80-M-US | 320–540 W | 79.5 V | 43–60 V | 48.9 / 30.3 V | ✗ Not a match: module voltage below MPPT range | 1.33 |
| APsystems (Alt Power System) DS3-L | 265–570 W | 60 V | 28–45 V | 48.9 / 30.3 V | ✓ Within range | 0.65 |
| City | kWh / kW / yr | kWh / panel / yr | kWh / system / yr | Sun, kWh/m²/day |
|---|---|---|---|---|
| Los Angeles | 1,676 | 846 | 11,849 | 6.08 |
| Palmdale | 1,835 | 927 | 12,973 | 6.69 |
| Chula Vista | 1,696 | 856 | 11,991 | 6.11 |
| Huntington Beach | 1,643 | 830 | 11,616 | 5.89 |
| Riverside | 1,696 | 856 | 11,991 | 6.21 |
| Santa Clarita | 1,724 | 871 | 12,189 | 6.28 |
| Panel | Pmax | Efficiency | γ Pmax (CEC) | Voc, V | Isc, A | SoCal permits (series) |
|---|---|---|---|---|---|---|
| SunSpark Technology SST-M132(HCBF) 505 | 505 W | ≈23.3% | −0.370 | 45.9 | 13.96 | — |
| SEG Solar SEG-505-BTD-BG | 505 W | ≈25.9% | −0.290 | 40.3 | 15.95 | 8 |
| Qcells Q.PEAK DUO XL-G10.d 505 | 505 W | ≈21.8% | −0.340 | 53.78 | 11.39 | 6 |
| AXITEC AC-530MH/144V | 530 W | ≥20.5% | −0.366 | 49.3 | 13.72 | 1 |
Calculated from the panel area (2.17 m²): about 23.3% for the 505 W class. 505 W over 2.17 m² equals about 233 W per square meter.
PVWatts v8 with typical-year weather gives about 846 kWh per year per 505 W panel in Los Angeles and about 927 kWh in Palmdale (20° roof, facing south, 14% system losses).
With γ = −0.370 %/°C, at a 77 °C cell temperature (hottest modeled hour in Palmdale) output is about 19.2% below the STC rating.
With the Tesla 1538000-xx-y (max DC 600 V, MPPT from 60 V, datasheet) in Los Angeles the calculator gives 2–12 panels per string (Voc at 2 °C = 48.9 V, Vmp at 74 °C cell = 30.3 V). Final design must follow the inverter manual and NEC 690.7.
Voltage check against the APsystems (Alt Power System) datasheet: Voc when cold 48.9 V vs max input 60 V; Vmp when hot 30.3 V vs MPPT low 28 V; recommended module power 265–570 W. Confirm on the microinverter maker’s compatibility list.
Yes. Rear gain depends on mounting height and ground reflectance.