Cali-GrafCali-Graf
Solar panelSunPower

SunPower SPR-X22-475-COM

128 cells. Power classes 460–485 W in the CEC list.

CEC listed · May 15, 2018UL 1703
Power class
  • Power (STC)475 WCEC nameplate
  • Efficiency≈22.0%calculated from area
  • %/°C Pmax−0.352CEC listing test
  • PTC / STC93.2%PTC 443 W (CEC)

Power classes

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation · 5 models
ModelPmaxVoc, VIsc, AVmp, VImp, AEfficiencyPTC
SPR-X22-460-COM460 W90.506.4076.706.00≈21.3%428 W
SPR-X22-470-COM470 W91.806.4377.906.03≈21.7%438 W
SPR-X22-475-COM475 W92.506.4578.506.07≈22.0%443 W
SPR-X22-480-COM480 W92.706.4879.006.08≈22.2%453 W
SPR-X22-485-COM485 W92.706.5578.806.16≈22.5%458 W
≈ efficiency = Pmax ÷ CEC-listed area 2.16 m².

Build & dimensions

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation

Heat & cold behaviour

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation
CEC listing test
Pmax coefficient γ−0.352 %/°C
Voc coefficient β−0.293 %/°C
Isc coefficient α+0.031 %/°C
Vmp coefficient−0.372 %/°C
Operating cell temperatureNOCT 45.7 °C

Away from lab conditions — CEC listing test points

ClassPmax at NOCTVmp × Imp at NOCTPmax at 200 W/m²Low-light efficiency vs STC
460 W339.7 W71.07 V × 4.78 A86.2 W94%
470 W346.5 W72.19 V × 4.8 A88.3 W94%
475 W351.3 W72.74 V × 4.83 A89.7 W94%
480 W357.4 W74.31 V × 4.81 A88.6 W92%
485 W361.2 W74.12 V × 4.87 A89.6 W92%
Pmax = Vmp × Imp from the CEC listing; low-light efficiency = Pmax at 200 W/m² ÷ (20% of STC Pmax).

Inverter compatibility & string sizing

CEC PV Module List (Oct 7, 2026) · NLR PVWatts v8 · inverter datasheets · NLR SAM inverter library · CEC Grid Support Inverter List (Oct 7, 2026)
98.7 V
Voc when cold
per panel
64.2 V
Vmp when hot
per panel
6
Max panels / string
max DC 600 V
1
Min panels / string
MPPT from 60 V
Defaults come from NLR TMY weather (coldest hour, hottest modeled cell). Code calculations (NEC 690.7) use the ASHRAE extreme annual minimum, which is usually colder — enter it above. β is the CEC-measured coefficient; NEC 690.7 calculations use the datasheet value.

String inverters most named in SoCal permits

InverterMax DC inputMPPTWindow sourcePanels per string
Tesla 1538000-xx-y600 V60–480 Vdatasheet1–6
Solis (Ginlong) S6-EH1P10K-H-US600 V80–520 Vdatasheet2–6
Solis (Ginlong) Solis-1P7.6K-4G-US600 V100–500 Vdatasheet2–6
Qcells Q.VOLT H7.6SX498 V234–498 VCEC test window4–5

Microinverters (one per panel)

MicroinverterRecommended module powerMax DC inputMPPTVoc cold / Vmp hotCheckDC/AC
Enphase IQ8X-80-M-US320–540 W79.5 V43–60 V98.7 / 64.2 V✗ Not allowed: cold Voc above max input1.25
APsystems (Alt Power System) DS3-L265–570 W60 V28–45 V98.7 / 64.2 V✗ Not allowed: cold Voc above max input0.61
Enphase IQ8A-72-2-US295–500 W60 V32–45 V98.7 / 64.2 V✗ Not allowed: cold Voc above max input1.36
Voltage check against the microinverter datasheets — confirm the pairing on the manufacturer’s module compatibility list. Rows appear only when the panel’s power is inside the microinverter’s recommended module power range.
SolarEdge and other optimizer-based systems size strings by the optimizer rules — use the manufacturer’s designer. Reference inverters: most named in SoCal permits since Oct 2024.

Expected production in Southern California

NLR PVWatts v8 · Cali-Graf calculation
CitykWh / kW / yrkWh / panel / yrkWh / system / yrSun, kWh/m²/day
Los Angeles1,67679611,9426.08
Palmdale1,83587213,0746.69
Chula Vista1,69680612,0846.11
Huntington Beach1,64378011,7065.89
Riverside1,69680612,0846.21
Santa Clarita1,72481912,2846.28
779Jan780Feb1,001Mar1,106Apr1,092May1,161Jun1,223Jul1,237Aug1,082Sep954Oct820Nov710DeckWh per month · Los Angeles
Estimate for comparison, not a quote: shading, roof orientation and local losses change real output. Roof mount, 20° tilt, south, 14% system losses.

Compare with similar 475 W panels

CEC PV Module List (Oct 7, 2026) · Kiwa PVEL Scorecard · datasheets · building permits
PanelPmaxEfficiencyγ Pmax (CEC)Voc, VIsc, ASizePVEL (product / brand)SoCal permits (series)
SunPower SPR-X22-475-COM475 W≈22%−0.35292.56.4581.4 in——
REC Group REC475AA Pure-RX475 W≈23.5%−0.24865.79—brand 9× (2016–2025)33
SEG Solar SEG-455-BTD-BG455 W≈23.3%−0.26239.7614.1167.8 × 44.6 inproduct 2023, 2024, 2025, 20268
Qcells Q.PEAK DUO XL-G10.d 475475 W≥20.5%−0.34053.5811.2487.2 × 41.1 inproduct 20236
Same fields from the same sources for every row; ≈ efficiency is calculated from the listed area. Comparable series: other brands, same product group, power range covering this class.

Questions & answers

How efficient is the SunPower SPR-X22-475-COM?

Calculated from the panel area (2.16 m²): about 22% for the 475 W class. 475 W over 2.16 m² equals about 220 W per square meter.

How much energy does one panel produce in Los Angeles or Palmdale?

PVWatts v8 with typical-year weather gives about 796 kWh per year per 475 W panel in Los Angeles and about 872 kWh in Palmdale (20° roof, facing south, 14% system losses).

How much power does it lose on a hot roof?

With γ = −0.352 %/°C, at a 77 °C cell temperature (hottest modeled hour in Palmdale) output is about 18.2% below the STC rating.

How many panels fit on one string?

With the Tesla 1538000-xx-y (max DC 600 V, MPPT from 60 V, datasheet) in Los Angeles the calculator gives 1–6 panels per string (Voc at 2 °C = 98.7 V, Vmp at 74 °C cell = 64.2 V). Final design must follow the inverter manual and NEC 690.7.

Sources

  1. California Energy Commission — Solar Equipment Lists, PV Module List, Inverter List (snapshot Oct 7, 2026).
  2. SEG Solar — manufacturer datasheet “XXXTFHTPMBSDPN YUKON/Series )BMG$FMM/5ZQF501$PO”.
  3. Qcells — manufacturer datasheet “Q.PEAK DUO XL-G10.d ENDURING HIGH PERFORMANCE”.
  4. Kiwa PVEL — PV Module Reliability Scorecard, Top Performer lists.
  5. NLR (formerly NREL) — System Advisor Model CEC inverter library (version 2026.7.3).
  6. NLR (formerly NREL) — PVWatts v8, NSRDB PSM v3 typical-year weather for Los Angeles, Palmdale, Chula Vista, Huntington Beach, Riverside, Santa Clarita.
  7. Inverter datasheets — APsystems (Alt Power System), Enphase, Solis (Ginlong), Tesla (manufacturer documents).
  8. Building permits — Southern California permit portals. Equipment matched from permit descriptions.
  9. Cali-Graf calculations — formulas and inputs are shown next to each calculated value (efficiency from area, temperature-corrected voltages, string sizing, energy estimates).