Cali-GrafCali-Graf
Solar panelSunPower

SunPower SPR-M465-COM

72 cells. Power classes 450–480 W in the CEC list.

CEC listed · Feb 11, 2022UL 61730
Power class
  • Power (STC)465 WCEC nameplate
  • Efficiency≈21.9%calculated from area
  • %/°C Pmax−0.296CEC listing test
  • PTC / STC94.1%PTC 437 W (CEC)

Power classes

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation · 7 models
ModelPmaxVoc, VIsc, AVmp, VImp, AEfficiencyPTCCEC listed
SPR-M450-COM450 W52.4311.5142.7610.52≈21.2%423 WFeb 11, 2022
SPR-M455-COM455 W52.4511.5242.9910.58≈21.5%428 WFeb 11, 2022
SPR-M460-COM460 W52.4811.5443.2310.64≈21.7%433 WFeb 11, 2022
SPR-M465-COM465 W52.5111.5543.4610.70≈21.9%437 WFeb 11, 2022
SPR-M470-COM470 W52.5311.5643.6910.76≈22.2%442 WFeb 11, 2022
SPR-M475-COM475 W52.5611.5743.9210.82≈22.4%447 WFeb 11, 2022
SPR-M480-COM480 W52.5911.5844.1510.87≈22.6%452 WFeb 11, 2022
≈ efficiency = Pmax ÷ CEC-listed area 2.12 m².

Build & dimensions

CEC PV Module List (Oct 7, 2026)

Heat & cold behaviour

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation
CEC listing test
Pmax coefficient γ−0.296 %/°C
Voc coefficient β−0.236 %/°C
Isc coefficient α+0.037 %/°C
Operating cell temperatureNOCT 46.5 °C
Vmp coefficient ≈ γ − α (CEC); used only for the hot-roof voltage estimate.

Away from lab conditions — CEC listing test points

ClassPmax at NOCTVmp × Imp at NOCTPmax at 200 W/m²Low-light efficiency vs STC
450 W331.4 W40.04 V × 8.28 A84.4 W94%
455 W335.1 W40.25 V × 8.32 A85.3 W94%
460 W338.9 W40.48 V × 8.37 A86.3 W94%
465 W342.6 W40.69 V × 8.42 A87.2 W94%
470 W346.3 W40.91 V × 8.47 A88.2 W94%
475 W350.1 W41.12 V × 8.51 A89.1 W94%
480 W353.6 W41.34 V × 8.55 A90 W94%
Pmax = Vmp × Imp from the CEC listing; low-light efficiency = Pmax at 200 W/m² ÷ (20% of STC Pmax).

Inverter compatibility & string sizing

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation · NLR PVWatts v8 · inverter datasheets · NLR SAM inverter library · CEC Grid Support Inverter List (Oct 7, 2026)
55.4 V
Voc when cold
per panel
36.4 V
Vmp when hot
per panel
10
Max panels / string
max DC 600 V
2
Min panels / string
MPPT from 60 V
Defaults come from NLR TMY weather (coldest hour, hottest modeled cell). Code calculations (NEC 690.7) use the ASHRAE extreme annual minimum, which is usually colder — enter it above. β is the CEC-measured coefficient; NEC 690.7 calculations use the datasheet value.

String inverters most named in SoCal permits

InverterMax DC inputMPPTWindow sourcePanels per string
Tesla 1538000-xx-y600 V60–480 Vdatasheet2–10
Solis (Ginlong) S6-EH1P10K-H-US600 V80–520 Vdatasheet3–10
Solis (Ginlong) Solis-1P7.6K-4G-US600 V100–500 Vdatasheet3–10
Qcells Q.VOLT H7.6SX498 V234–498 VCEC test window7–9

Microinverters (one per panel)

MicroinverterRecommended module powerMax DC inputMPPTVoc cold / Vmp hotCheckDC/AC
Enphase IQ8X-80-M-US320–540 W79.5 V43–60 V55.4 / 36.4 V⚠ Works; below MPPT at peak heat1.22
APsystems (Alt Power System) DS3-L265–570 W60 V28–45 V55.4 / 36.4 V✓ Within range0.6
Enphase IQ8A-72-2-US295–500 W60 V32–45 V55.4 / 36.4 V✓ Within range1.33
Voltage check against the microinverter datasheets — confirm the pairing on the manufacturer’s module compatibility list. Rows appear only when the panel’s power is inside the microinverter’s recommended module power range.
SolarEdge and other optimizer-based systems size strings by the optimizer rules — use the manufacturer’s designer. Reference inverters: most named in SoCal permits since Oct 2024.

Expected production in Southern California

NLR PVWatts v8 · Cali-Graf calculation
CitykWh / kW / yrkWh / panel / yrkWh / system / yrSun, kWh/m²/day
Los Angeles1,67677911,6906.08
Palmdale1,83585312,7996.69
Chula Vista1,69678911,8306.11
Huntington Beach1,64376411,4605.89
Riverside1,69678911,8306.21
Santa Clarita1,72480212,0256.28
763Jan764Feb980Mar1,083Apr1,069May1,136Jun1,197Jul1,211Aug1,059Sep934Oct803Nov695DeckWh per month · Los Angeles
Estimate for comparison, not a quote: shading, roof orientation and local losses change real output. Roof mount, 20° tilt, south, 14% system losses.

Compare with similar 465 W panels

CEC PV Module List (Oct 7, 2026) · Kiwa PVEL Scorecard · datasheets · building permits
PanelPmaxEfficiencyγ Pmax (CEC)Voc, VIsc, ASoCal permits (series)
SunPower SPR-M465-COM465 W≈21.9%−0.29652.5111.55—
REC Group REC465AA Pure-RX465 W≈23%−0.24865.78.9133
Aptos Solar DNA-120-MF10-465W465 W≈21.5%−0.36341.914.0722
Canadian Solar CS6.1-54TM-465H465 W≥22.8%−0.30839.514.779
Same fields from the same sources for every row; ≈ efficiency is calculated from the listed area. Comparable series: other brands, same product group, power range covering this class.

Questions & answers

How efficient is the SunPower SPR-M465-COM?

Calculated from the panel area (2.12 m²): about 21.9% for the 465 W class. 465 W over 2.12 m² equals about 219 W per square meter.

How much energy does one panel produce in Los Angeles or Palmdale?

PVWatts v8 with typical-year weather gives about 779 kWh per year per 465 W panel in Los Angeles and about 853 kWh in Palmdale (20° roof, facing south, 14% system losses).

How much power does it lose on a hot roof?

With γ = −0.296 %/°C, at a 77 °C cell temperature (hottest modeled hour in Palmdale) output is about 15.3% below the STC rating.

How many panels fit on one string?

With the Tesla 1538000-xx-y (max DC 600 V, MPPT from 60 V, datasheet) in Los Angeles the calculator gives 2–10 panels per string (Voc at 2 °C = 55.4 V, Vmp at 74 °C cell = 36.4 V). Final design must follow the inverter manual and NEC 690.7.

Does it work with APsystems (Alt Power System) DS3-L microinverters?

Voltage check against the APsystems (Alt Power System) datasheet: Voc when cold 55.4 V vs max input 60 V; Vmp when hot 36.4 V vs MPPT low 28 V; recommended module power 265–570 W. Confirm on the microinverter maker’s compatibility list.

Sources

  1. California Energy Commission — Solar Equipment Lists, PV Module List, Inverter List (snapshot Oct 7, 2026).
  2. Aptos Solar — datasheet Legacy Products.
  3. Canadian Solar — datasheet TOPHiKu6 (All-Black) N-type TOPCon Technology CS6.1-54TM-435|440|445|450|455|460|465H.
  4. Kiwa PVEL — PV Module Reliability Scorecard, Top Performer lists.
  5. NLR (formerly NREL) — System Advisor Model CEC inverter library (version 2026.7.3).
  6. NLR (formerly NREL) — PVWatts v8, NSRDB PSM v3 typical-year weather for Los Angeles, Palmdale, Chula Vista, Huntington Beach, Riverside, Santa Clarita.
  7. Inverter datasheets — APsystems (Alt Power System), Enphase, Solis (Ginlong), Tesla (manufacturer documents).
  8. Building permits — Southern California permit portals. Equipment matched from permit descriptions.
  9. Cali-Graf calculations — formulas and inputs are shown next to each calculated value (efficiency from area, temperature-corrected voltages, string sizing, energy estimates).