Cali-GrafCali-Graf
Solar panelSunPower

SunPower SPR-MAX3-410-R

112 cells. Power classes 395–435 W in the CEC list.

CEC listed · Mar 1, 2023UL 61730
Power class
  • Power (STC)410 WCEC nameplate
  • Efficiency≈21.6%calculated from area
  • %/°C Pmax−0.280CEC listing test
  • PTC / STC94.5%PTC 387 W (CEC)

Power classes

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation · 8 models
ModelPmaxVoc, VIsc, AVmp, VImp, AEfficiencyPTCCEC listed
SPR-MAX3-395-R395 W40.5213.0433.6711.73≈20.8%373 WMar 1, 2023
SPR-MAX3-400-R400 W40.5513.0633.8811.81≈21.1%378 WMar 1, 2023
SPR-MAX3-405-R405 W40.5713.0734.0811.88≈21.3%382 WMar 1, 2023
SPR-MAX3-410-R410 W40.5913.0934.2911.96≈21.6%387 WMar 1, 2023
SPR-MAX3-415-R415 W40.6113.1034.4912.03≈21.8%392 WMar 1, 2023
SPR-MAX3-425-R425 W40.6613.1334.9012.18≈22.4%402 WMar 1, 2023
SPR-MAX3-430-R430 W40.6813.1535.1112.25≈22.6%407 WMar 1, 2023
SPR-MAX3-435-R435 W40.7013.1635.3112.32≈22.9%412 WMar 1, 2023
≈ efficiency = Pmax ÷ CEC-listed area 1.9 m².

Build & dimensions

CEC PV Module List (Oct 7, 2026)

Heat & cold behaviour

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation
CEC listing test
Pmax coefficient γ−0.280 %/°C
Voc coefficient β−0.234 %/°C
Isc coefficient α+0.045 %/°C
Operating cell temperatureNOCT 46 °C
Vmp coefficient ≈ γ − α (CEC); used only for the hot-roof voltage estimate.

Away from lab conditions — CEC listing test points

ClassPmax at NOCTVmp × Imp at NOCTPmax at 200 W/m²Low-light efficiency vs STC
395 W292.8 W31.01 V × 9.44 A73.8 W93%
400 W296.7 W31.2 V × 9.51 A74.8 W93%
405 W300.2 W31.39 V × 9.56 A75.6 W93%
410 W304.1 W31.58 V × 9.63 A76.6 W93%
415 W307.6 W31.76 V × 9.69 A77.5 W93%
425 W315.2 W32.14 V × 9.81 A79.4 W93%
430 W318.9 W32.33 V × 9.86 A80.4 W93%
435 W322.5 W32.52 V × 9.92 A81.3 W93%
Pmax = Vmp × Imp from the CEC listing; low-light efficiency = Pmax at 200 W/m² ÷ (20% of STC Pmax).

Inverter compatibility & string sizing

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation · NLR PVWatts v8 · inverter datasheets · NLR SAM inverter library · CEC Grid Support Inverter List (Oct 7, 2026)
42.8 V
Voc when cold
per panel
28.8 V
Vmp when hot
per panel
14
Max panels / string
max DC 600 V
3
Min panels / string
MPPT from 60 V
Defaults come from NLR TMY weather (coldest hour, hottest modeled cell). Code calculations (NEC 690.7) use the ASHRAE extreme annual minimum, which is usually colder — enter it above. β is the CEC-measured coefficient; NEC 690.7 calculations use the datasheet value.

String inverters most named in SoCal permits

InverterMax DC inputMPPTWindow sourcePanels per string
Tesla 1538000-xx-y600 V60–480 Vdatasheet3–14
Solis (Ginlong) S6-EH1P10K-H-US600 V80–520 Vdatasheet3–14
Solis (Ginlong) Solis-1P7.6K-4G-US600 V100–500 Vdatasheet4–14
Qcells Q.VOLT H7.6SX498 V234–498 VCEC test window9–11

Microinverters (one per panel)

MicroinverterRecommended module powerMax DC inputMPPTVoc cold / Vmp hotCheckDC/AC
Enphase IQ8PLUS-72-2-US235–440 W60 V29–45 V42.8 / 28.8 V⚠ Works; below MPPT at peak heat1.41
Enphase IQ8X-80-M-US320–540 W79.5 V43–60 V42.8 / 28.8 V✗ Not a match: module voltage below MPPT range1.08
APsystems (Alt Power System) DS3-L265–570 W60 V28–45 V42.8 / 28.8 V✓ Within range0.53
Enphase IQ8M-72-2-US260–460 W60 V30–45 V42.8 / 28.8 V⚠ Works; below MPPT at peak heat1.26
Enphase IQ8A-72-2-US295–500 W60 V32–45 V42.8 / 28.8 V⚠ Works; below MPPT at peak heat1.17
Voltage check against the microinverter datasheets — confirm the pairing on the manufacturer’s module compatibility list. Rows appear only when the panel’s power is inside the microinverter’s recommended module power range.
SolarEdge and other optimizer-based systems size strings by the optimizer rules — use the manufacturer’s designer. Reference inverters: most named in SoCal permits since Oct 2024.

Expected production in Southern California

NLR PVWatts v8 · Cali-Graf calculation
CitykWh / kW / yrkWh / panel / yrkWh / system / yrSun, kWh/m²/day
Los Angeles1,67668711,6826.08
Palmdale1,83575212,7906.69
Chula Vista1,69669511,8216.11
Huntington Beach1,64367411,4525.89
Riverside1,69669511,8216.21
Santa Clarita1,72470712,0166.28
763Jan763Feb979Mar1,082Apr1,069May1,135Jun1,196Jul1,210Aug1,058Sep933Oct802Nov694DeckWh per month · Los Angeles
Estimate for comparison, not a quote: shading, roof orientation and local losses change real output. Roof mount, 20° tilt, south, 14% system losses.

Compare with similar 410 W panels

CEC PV Module List (Oct 7, 2026) · Qcells datasheet · Kiwa PVEL Scorecard · building permits
PanelPmaxEfficiencyγ Pmax (CEC)Voc, VIsc, APVEL (product / brand)SoCal permits (series)
SunPower SPR-MAX3-410-R410 W≈21.6%−0.28040.5913.09——
Qcells Q.PEAK DUO BLK ML-G10+ 410410 W≈20.9%−0.33745.3711.2product 2022, 2023221
JA Solar JAM54S31-405/MR405 W≈21.3%−0.32937.2313.87product 2023, 2024152
REC Group REC410AA Pure410 W≈22.9%−0.2564910.35brand 9× (2016–2025)66
Same fields from the same sources for every row; ≈ efficiency is calculated from the listed area. Comparable series: other brands, same product group, power range covering this class.

Questions & answers

How efficient is the SunPower SPR-MAX3-410-R?

Calculated from the panel area (1.9 m²): about 21.6% for the 410 W class. 410 W over 1.9 m² equals about 216 W per square meter.

How much energy does one panel produce in Los Angeles or Palmdale?

PVWatts v8 with typical-year weather gives about 687 kWh per year per 410 W panel in Los Angeles and about 752 kWh in Palmdale (20° roof, facing south, 14% system losses).

How much power does it lose on a hot roof?

With γ = −0.280 %/°C, at a 77 °C cell temperature (hottest modeled hour in Palmdale) output is about 14.5% below the STC rating.

How many panels fit on one string?

With the Tesla 1538000-xx-y (max DC 600 V, MPPT from 60 V, datasheet) in Los Angeles the calculator gives 3–14 panels per string (Voc at 2 °C = 42.8 V, Vmp at 74 °C cell = 28.8 V). Final design must follow the inverter manual and NEC 690.7.

Does it work with APsystems (Alt Power System) DS3-L microinverters?

Voltage check against the APsystems (Alt Power System) datasheet: Voc when cold 42.8 V vs max input 60 V; Vmp when hot 28.8 V vs MPPT low 28 V; recommended module power 265–570 W. Confirm on the microinverter maker’s compatibility list.

Sources

  1. California Energy Commission — Solar Equipment Lists, PV Module List, Inverter List (snapshot Oct 7, 2026).
  2. Qcells — manufacturer datasheet “Q.PEAK DUO BLK ML-G10+ ENDURING HIGH PERFORMANCE”.
  3. Kiwa PVEL — PV Module Reliability Scorecard, Top Performer lists.
  4. NLR (formerly NREL) — System Advisor Model CEC inverter library (version 2026.7.3).
  5. NLR (formerly NREL) — PVWatts v8, NSRDB PSM v3 typical-year weather for Los Angeles, Palmdale, Chula Vista, Huntington Beach, Riverside, Santa Clarita.
  6. Inverter datasheets — APsystems (Alt Power System), Enphase, Solis (Ginlong), Tesla (manufacturer documents).
  7. Building permits — Southern California permit portals. Equipment matched from permit descriptions.
  8. Cali-Graf calculations — formulas and inputs are shown next to each calculated value (efficiency from area, temperature-corrected voltages, string sizing, energy estimates).