144 half-cut cells, bifacial. Power classes 535–560 W in the CEC list.
| Model | Pmax | Voc, V | Isc, A | Vmp, V | Imp, A | Efficiency | PTC | CEC listed |
|---|---|---|---|---|---|---|---|---|
| SR4-72HBD-535M | 535 W | 49.70 | 13.57 | 41.80 | 12.81 | ≈21.6% | 496 W | Aug 11, 2023 |
| SR4-72HBD-540M | 540 W | 49.90 | 13.66 | 41.90 | 12.88 | ≈21.8% | 501 W | Aug 11, 2023 |
| SR4-72HBD-545M | 545 W | 50.10 | 13.75 | 42.10 | 12.95 | ≈22.0% | 506 W | Aug 11, 2023 |
| SR4-72HBD-550M | 550 W | 50.30 | 13.82 | 42.30 | 13.01 | ≈22.2% | 511 W | Aug 11, 2023 |
| SR4-72HBD-555M | 555 W | 50.50 | 13.89 | 42.40 | 13.08 | ≈22.4% | 515 W | Aug 11, 2023 |
| SR4-72HBD-560M | 560 W | 50.70 | 13.96 | 42.60 | 13.14 | ≈22.6% | 520 W | Aug 11, 2023 |
| CEC listing test | |
|---|---|
| Pmax coefficient γ | −0.375 %/°C |
| Voc coefficient β | −0.284 %/°C |
| Isc coefficient α | +0.048 %/°C |
| Operating cell temperature | NOCT 45.6 °C |
| Class | Pmax at NOCT | Vmp × Imp at NOCT | Pmax at 200 W/m² | Low-light efficiency vs STC |
|---|---|---|---|---|
| 535 W | 400.1 W | 38.4 V × 10.42 A | 108.3 W | 101% |
| 540 W | 404.5 W | 38.6 V × 10.48 A | 109.1 W | 101% |
| 545 W | 407.5 W | 38.7 V × 10.53 A | 109.9 W | 101% |
| 550 W | 412 W | 38.9 V × 10.59 A | 111.2 W | 101% |
| 555 W | 416 W | 39.1 V × 10.64 A | 112.1 W | 101% |
| 560 W | 419.4 W | 39.2 V × 10.7 A | 113.3 W | 101% |
| Inverter | Max DC input | MPPT | Window source | Panels per string |
|---|---|---|---|---|
| Tesla 1538000-xx-y | 600 V | 60–480 V | datasheet | 2–11 |
| Solis (Ginlong) S6-EH1P10K-H-US | 600 V | 80–520 V | datasheet | 3–11 |
| Solis (Ginlong) Solis-1P7.6K-4G-US | 600 V | 100–500 V | datasheet | 3–11 |
| Qcells Q.VOLT H7.6SX | 498 V | 234–498 V | CEC test window | 8–9 |
| Microinverter | Recommended module power | Max DC input | MPPT | Voc cold / Vmp hot | Check | DC/AC |
|---|---|---|---|---|---|---|
| APsystems (Alt Power System) DS3-L | 265–570 W | 60 V | 28–45 V | 53.4 / 33.4 V | ✓ Within range | 0.7 |
| City | kWh / kW / yr | kWh / panel / yr | kWh / system / yr | Sun, kWh/m²/day |
|---|---|---|---|---|
| Los Angeles | 1,676 | 913 | 11,874 | 6.08 |
| Palmdale | 1,835 | 1,000 | 13,001 | 6.69 |
| Chula Vista | 1,696 | 924 | 12,016 | 6.11 |
| Huntington Beach | 1,643 | 895 | 11,641 | 5.89 |
| Riverside | 1,696 | 924 | 12,016 | 6.21 |
| Santa Clarita | 1,724 | 940 | 12,215 | 6.28 |
| Panel | Pmax | Efficiency | γ Pmax (CEC) | Voc, V | Isc, A | PVEL (product / brand) | SoCal permits (series) |
|---|---|---|---|---|---|---|---|
| Sunplus Optimum SR4-72HBD-545M | 545 W | ≈22% | −0.375 | 50.1 | 13.75 | — | — |
| JA Solar JAM72D30-545/MB | 545 W | ≈21.6% | −0.330 | 49.75 | 13.93 | product 2023, 2024 | 3 |
| LONGi LR5-72HBD-545M | 545 W | ≥21.3% | −0.354 | 49.65 | 13.92 | product 2026 | 1 |
| Canadian Solar CS6W-545MB-AG | 545 W | ≈21.2% | −0.324 | 49.4 | 13.95 | product 2024 | 1 |
Calculated from the panel area (2.48 m²): about 22% for the 545 W class. 545 W over 2.48 m² equals about 220 W per square meter.
PVWatts v8 with typical-year weather gives about 913 kWh per year per 545 W panel in Los Angeles and about 1,000 kWh in Palmdale (20° roof, facing south, 14% system losses).
With γ = −0.375 %/°C, at a 77 °C cell temperature (hottest modeled hour in Palmdale) output is about 19.4% below the STC rating.
With the Tesla 1538000-xx-y (max DC 600 V, MPPT from 60 V, datasheet) in Los Angeles the calculator gives 2–11 panels per string (Voc at 2 °C = 53.4 V, Vmp at 74 °C cell = 33.4 V). Final design must follow the inverter manual and NEC 690.7.
Voltage check against the APsystems (Alt Power System) datasheet: Voc when cold 53.4 V vs max input 60 V; Vmp when hot 33.4 V vs MPPT low 28 V; recommended module power 265–570 W. Confirm on the microinverter maker’s compatibility list.
Yes. Rear gain depends on mounting height and ground reflectance.