Solar panelSunpal Power

Sunpal Power SP525M-72HB

144 half-cut cells. Power classes 435–570 W in the CEC list.

CEC listed · Apr 3, 2023UL 61730
Power class
  • Power (STC)525 WCEC nameplate
  • Efficiency≈20.3%calculated from area
  • %/°C Pmax−0.304CEC listing test
  • PTC / STC93.9%PTC 493 W (CEC)

Power classes

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation · 19 models
ModelPmaxVoc, VIsc, AVmp, VImp, AEfficiencyPTCCEC listed
SP435M-72HB435 W49.3611.2340.7210.69≈20.0%404 WApr 3, 2023
SP440M-72HB440 W49.5611.3040.9210.76≈20.3%409 WApr 3, 2023
SP445M-72HB445 W49.7611.3741.1010.83≈20.5%414 WApr 3, 2023
SP450M-72HB450 W50.0011.4441.3210.90≈20.7%419 WApr 3, 2023
SP455M-72HB455 W50.1611.5141.5210.96≈21.0%424 WApr 3, 2023
SP460M-72HB460 W50.3611.5841.7211.03≈21.2%428 WApr 3, 2023
SP465M-72HB465 W50.5611.6541.9211.10≈21.4%433 WApr 3, 2023
SP470M-72HB470 W50.7611.7242.1211.17≈21.7%438 WApr 3, 2023
SP520M-72HB520 W49.1813.5440.5012.84≈20.2%488 WApr 3, 2023
SP525M-72HB525 W49.2813.6140.5912.94≈20.3%493 WApr 3, 2023
SP530M-72HB530 W49.3813.6840.6813.03≈20.5%498 WApr 3, 2023
SP535M-72HB535 W49.4813.7540.7713.13≈20.7%503 WApr 3, 2023
SP540M-72HB540 W49.5813.8240.8613.22≈20.9%508 WApr 3, 2023
SP545M-72HB545 W49.6813.8940.9513.31≈21.1%512 WApr 3, 2023
SP550M-72HB550 W49.7813.9641.0413.41≈21.3%517 WApr 3, 2023
SP555M-72HB555 W49.8814.0341.1313.50≈21.5%522 WApr 3, 2023
SP560M-72HB560 W49.9814.1041.2213.59≈21.7%527 WApr 3, 2023
SP565M-72HB565 W50.0814.1741.3113.68≈21.9%532 WApr 3, 2023
SP570M-72HB570 W50.1814.2441.4013.77≈22.1%536 WApr 3, 2023
≈ efficiency = Pmax ÷ CEC-listed area 2.17 m².

Build & dimensions

CEC PV Module List (Oct 7, 2026)

Heat & cold behaviour

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation
CEC listing test
Pmax coefficient γ−0.304 %/°C
Voc coefficient β−0.260 %/°C
Isc coefficient α+0.054 %/°C
Operating cell temperatureNOCT 45.8 °C
Vmp coefficient ≈ γ − α (CEC); used only for the hot-roof voltage estimate.

Away from lab conditions — CEC listing test points

ClassPmax at NOCTVmp × Imp at NOCTPmax at 200 W/m²Low-light efficiency vs STC
435 W330.1 W38.36 V × 8.6 A85.5 W98%
440 W333.9 W38.55 V × 8.66 A86.4 W98%
445 W337.7 W38.74 V × 8.72 A87.4 W98%
450 W341.5 W38.93 V × 8.77 A88.4 W98%
455 W345 W39.12 V × 8.82 A89.3 W98%
460 W348.9 W39.3 V × 8.88 A90.3 W98%
465 W352.8 W39.49 V × 8.93 A91.3 W98%
470 W356.7 W39.68 V × 8.99 A92.4 W98%
520 W393.9 W38.55 V × 10.22 A102.2 W98%
525 W397.6 W38.64 V × 10.29 A103.1 W98%
530 W401.2 W38.72 V × 10.36 A104.1 W98%
535 W405.2 W38.81 V × 10.44 A105.1 W98%
540 W408.9 W38.9 V × 10.51 A106.1 W98%
545 W412.6 W38.98 V × 10.58 A107 W98%
550 W416.6 W39.07 V × 10.66 A108.1 W98%
555 W420.3 W39.15 V × 10.74 A109 W98%
560 W424 W39.24 V × 10.81 A110 W98%
565 W427.8 W39.32 V × 10.88 A111 W98%
570 W431.5 W39.41 V × 10.95 A111.9 W98%
Pmax = Vmp × Imp from the CEC listing; low-light efficiency = Pmax at 200 W/m² ÷ (20% of STC Pmax).

Inverter compatibility & string sizing

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation · NLR PVWatts v8 · inverter datasheets · NLR SAM inverter library · CEC Grid Support Inverter List (Oct 7, 2026)
52.2 V
Voc when cold
per panel
33.5 V
Vmp when hot
per panel
11
Max panels / string
max DC 600 V
2
Min panels / string
MPPT from 60 V
Defaults come from NLR TMY weather (coldest hour, hottest modeled cell). Code calculations (NEC 690.7) use the ASHRAE extreme annual minimum, which is usually colder — enter it above. β is the CEC-measured coefficient; NEC 690.7 calculations use the datasheet value.

String inverters most named in SoCal permits

InverterMax DC inputMPPTWindow sourcePanels per string
Tesla 1538000-xx-y600 V60–480 Vdatasheet2–11
Solis (Ginlong) S6-EH1P10K-H-US600 V80–520 Vdatasheet3–11
Solis (Ginlong) Solis-1P7.6K-4G-US600 V100–500 Vdatasheet3–11
Qcells Q.VOLT H7.6SX498 V234–498 VCEC test window7–9

Microinverters (one per panel)

MicroinverterRecommended module powerMax DC inputMPPTVoc cold / Vmp hotCheckDC/AC
Enphase IQ8X-80-M-US320–540 W79.5 V43–60 V52.2 / 33.5 V✗ Not a match: module voltage below MPPT range1.38
APsystems (Alt Power System) DS3-L265–570 W60 V28–45 V52.2 / 33.5 V✓ Within range0.67
Voltage check against the microinverter datasheets — confirm the pairing on the manufacturer’s module compatibility list. Rows appear only when the panel’s power is inside the microinverter’s recommended module power range.
SolarEdge and other optimizer-based systems size strings by the optimizer rules — use the manufacturer’s designer. Reference inverters: most named in SoCal permits since Oct 2024.

Expected production in Southern California

NLR PVWatts v8 · Cali-Graf calculation
CitykWh / kW / yrkWh / panel / yrkWh / system / yrSun, kWh/m²/day
Los Angeles1,67688011,4396.08
Palmdale1,83596312,5246.69
Chula Vista1,69689011,5756.11
Huntington Beach1,64386311,2135.89
Riverside1,69689011,5756.21
Santa Clarita1,72490511,7666.28
747Jan747Feb959Mar1,059Apr1,046May1,112Jun1,171Jul1,185Aug1,036Sep914Oct786Nov680DeckWh per month · Los Angeles
Estimate for comparison, not a quote: shading, roof orientation and local losses change real output. Roof mount, 20° tilt, south, 14% system losses.

Compare with similar 525 W panels

CEC PV Module List (Oct 7, 2026) · datasheets · Kiwa PVEL Scorecard · building permits
PanelPmaxEfficiencyγ Pmax (CEC)Voc, VIsc, APVEL (product / brand)SoCal permits (series)
Sunpal Power SP525M-72HB525 W≈20.3%−0.30449.2813.61——
SEG Solar SEG-525-BTD-BG525 W≈26.9%−0.29041.116.2product 2023, 2024, 2025, 20268
JA Solar JAM72D30-530/MB530 W≈21%−0.33049.313.72product 2023, 20243
Canadian Solar CS6W-525MB-AG525 W≈20.4%−0.32448.613.75product 20241
Same fields from the same sources for every row; ≈ efficiency is calculated from the listed area. Comparable series: other brands, same product group, power range covering this class.

Questions & answers

How efficient is the Sunpal Power SP525M-72HB?

Calculated from the panel area (2.58 m²): about 20.3% for the 525 W class. 525 W over 2.58 m² equals about 203 W per square meter.

How much energy does one panel produce in Los Angeles or Palmdale?

PVWatts v8 with typical-year weather gives about 880 kWh per year per 525 W panel in Los Angeles and about 963 kWh in Palmdale (20° roof, facing south, 14% system losses).

How much power does it lose on a hot roof?

With γ = −0.304 %/°C, at a 77 °C cell temperature (hottest modeled hour in Palmdale) output is about 15.8% below the STC rating.

How many panels fit on one string?

With the Tesla 1538000-xx-y (max DC 600 V, MPPT from 60 V, datasheet) in Los Angeles the calculator gives 2–11 panels per string (Voc at 2 °C = 52.2 V, Vmp at 74 °C cell = 33.5 V). Final design must follow the inverter manual and NEC 690.7.

Does it work with APsystems (Alt Power System) DS3-L microinverters?

Voltage check against the APsystems (Alt Power System) datasheet: Voc when cold 52.2 V vs max input 60 V; Vmp when hot 33.5 V vs MPPT low 28 V; recommended module power 265–570 W. Confirm on the microinverter maker’s compatibility list.

Sources

  1. California Energy Commission — Solar Equipment Lists, PV Module List, Inverter List (snapshot Oct 7, 2026).
  2. SEG Solar — manufacturer datasheet “XXXTFHTPMBSDPN YUKON/Series )BMG$FMM/5ZQF501$PO”.
  3. Canadian Solar — datasheet BiHiKu6 BIFACIAL MONO PERC CS6W-520|525|530|535|540|545|550MB-AG.
  4. Kiwa PVEL — PV Module Reliability Scorecard, Top Performer lists.
  5. NLR (formerly NREL) — System Advisor Model CEC inverter library (version 2026.7.3).
  6. NLR (formerly NREL) — PVWatts v8, NSRDB PSM v3 typical-year weather for Los Angeles, Palmdale, Chula Vista, Huntington Beach, Riverside, Santa Clarita.
  7. Inverter datasheets — APsystems (Alt Power System), Enphase, Solis (Ginlong), Tesla (manufacturer documents).
  8. Building permits — Southern California permit portals. Equipment matched from permit descriptions.
  9. Cali-Graf calculations — formulas and inputs are shown next to each calculated value (efficiency from area, temperature-corrected voltages, string sizing, energy estimates).