Cali-GrafCali-Graf
Building-integrated solar panelSunflare

Sunflare FLEX60-170W-M20-A

60 cells. Power classes 160–185 W in the CEC list.

CEC listed · Mar 23, 2020UL 1703Building-integrated (BIPV)
Power class
  • Power (STC)170 WCEC nameplate
  • Efficiency≈10.4%calculated from area
  • %/°C Pmax−0.385CEC listing test
  • PTC / STC86.6%PTC 147 W (CEC)

Power classes

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation · 6 models
ModelPmaxVoc, VIsc, AVmp, VImp, AEfficiencyPTCCEC listed
FLEX60-160W-M20-A160 W35.117.1927.635.80≈9.8%138 WMar 23, 2020
FLEX60-165W-M20-A165 W35.427.2827.506.00≈10.1%143 WMar 23, 2020
FLEX60-170W-M20-A170 W35.747.3827.376.21≈10.4%147 WMar 23, 2020
FLEX60-175W-M20-A175 W35.957.4228.186.22≈10.7%152 WMar 23, 2020
FLEX60-180W-M20-A180 W36.407.4328.686.28≈11.0%156 WMar 23, 2020
FLEX60-185W-M20-A185 W36.637.5328.336.53≈11.3%161 WMar 23, 2020
≈ efficiency = Pmax ÷ CEC-listed area 1.64 m².

Build & dimensions

CEC PV Module List (Oct 7, 2026)

Heat & cold behaviour

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation
CEC listing test
Pmax coefficient γ−0.385 %/°C
Voc coefficient β−0.313 %/°C
Operating cell temperatureNOCT 55.9 °C

Away from lab conditions — CEC listing test points

ClassPmax at NOCTVmp × Imp at NOCTPmax at 200 W/m²Low-light efficiency vs STC
160 W100.9 W23.43 V × 4.31 A23.1 W72%
165 W103.9 W23.31 V × 4.45 A23.8 W72%
170 W107 W23.2 V × 4.61 A24.5 W72%
175 W110.3 W23.89 V × 4.62 A25.3 W72%
180 W113.4 W24.32 V × 4.66 A26 W72%
185 W116.4 W24.02 V × 4.85 A26.7 W72%
Pmax = Vmp × Imp from the CEC listing; low-light efficiency = Pmax at 200 W/m² ÷ (20% of STC Pmax).

Expected production in Southern California

NLR PVWatts v8 · Cali-Graf calculation
CitykWh / kW / yrkWh / panel / yrkWh / system / yrSun, kWh/m²/day
Los Angeles1,6762858,5486.08
Palmdale1,8353129,3586.69
Chula Vista1,6962888,6506.11
Huntington Beach1,6432798,3795.89
Riverside1,6962888,6506.21
Santa Clarita1,7242938,7926.28
558Jan558Feb717Mar792Apr782May831Jun875Jul885Aug774Sep683Oct587Nov508DeckWh per month · Los Angeles
PVWatts models a standard roof-mounted module; integrated roof products are not modeled separately.
Estimate for comparison, not a quote: shading, roof orientation and local losses change real output. Roof mount, 20° tilt, south, 14% system losses.

Questions & answers

How efficient is the Sunflare FLEX60-170W-M20-A?

Calculated from the panel area (1.64 m²): about 10.4% for the 170 W class. 170 W over 1.64 m² equals about 104 W per square meter.

How much energy does one panel produce in Los Angeles or Palmdale?

PVWatts v8 with typical-year weather gives about 285 kWh per year per 170 W panel in Los Angeles and about 312 kWh in Palmdale (20° roof, facing south, 14% system losses).

How much power does it lose on a hot roof?

With γ = −0.385 %/°C, at a 77 °C cell temperature (hottest modeled hour in Palmdale) output is about 19.9% below the STC rating.

Sources

  1. California Energy Commission — Solar Equipment Lists, PV Module List (snapshot Oct 7, 2026).
  2. NLR (formerly NREL) — PVWatts v8, NSRDB PSM v3 typical-year weather for Los Angeles, Palmdale, Chula Vista, Huntington Beach, Riverside, Santa Clarita.
  3. Cali-Graf calculations — formulas and inputs are shown next to each calculated value (efficiency from area, temperature-corrected voltages, string sizing, energy estimates).