60 cells. Power classes 160–185 W in the CEC list.
| Model | Pmax | Voc, V | Isc, A | Vmp, V | Imp, A | Efficiency | PTC | CEC listed |
|---|---|---|---|---|---|---|---|---|
| FLEX60-160W-M20-A | 160 W | 35.11 | 7.19 | 27.63 | 5.80 | ≈9.8% | 138 W | Mar 23, 2020 |
| FLEX60-165W-M20-A | 165 W | 35.42 | 7.28 | 27.50 | 6.00 | ≈10.1% | 143 W | Mar 23, 2020 |
| FLEX60-170W-M20-A | 170 W | 35.74 | 7.38 | 27.37 | 6.21 | ≈10.4% | 147 W | Mar 23, 2020 |
| FLEX60-175W-M20-A | 175 W | 35.95 | 7.42 | 28.18 | 6.22 | ≈10.7% | 152 W | Mar 23, 2020 |
| FLEX60-180W-M20-A | 180 W | 36.40 | 7.43 | 28.68 | 6.28 | ≈11.0% | 156 W | Mar 23, 2020 |
| FLEX60-185W-M20-A | 185 W | 36.63 | 7.53 | 28.33 | 6.53 | ≈11.3% | 161 W | Mar 23, 2020 |
| CEC listing test | |
|---|---|
| Pmax coefficient γ | −0.385 %/°C |
| Voc coefficient β | −0.313 %/°C |
| Operating cell temperature | NOCT 55.9 °C |
| Class | Pmax at NOCT | Vmp × Imp at NOCT | Pmax at 200 W/m² | Low-light efficiency vs STC |
|---|---|---|---|---|
| 160 W | 100.9 W | 23.43 V × 4.31 A | 23.1 W | 72% |
| 165 W | 103.9 W | 23.31 V × 4.45 A | 23.8 W | 72% |
| 170 W | 107 W | 23.2 V × 4.61 A | 24.5 W | 72% |
| 175 W | 110.3 W | 23.89 V × 4.62 A | 25.3 W | 72% |
| 180 W | 113.4 W | 24.32 V × 4.66 A | 26 W | 72% |
| 185 W | 116.4 W | 24.02 V × 4.85 A | 26.7 W | 72% |
| City | kWh / kW / yr | kWh / panel / yr | kWh / system / yr | Sun, kWh/m²/day |
|---|---|---|---|---|
| Los Angeles | 1,676 | 285 | 8,548 | 6.08 |
| Palmdale | 1,835 | 312 | 9,358 | 6.69 |
| Chula Vista | 1,696 | 288 | 8,650 | 6.11 |
| Huntington Beach | 1,643 | 279 | 8,379 | 5.89 |
| Riverside | 1,696 | 288 | 8,650 | 6.21 |
| Santa Clarita | 1,724 | 293 | 8,792 | 6.28 |
Calculated from the panel area (1.64 m²): about 10.4% for the 170 W class. 170 W over 1.64 m² equals about 104 W per square meter.
PVWatts v8 with typical-year weather gives about 285 kWh per year per 170 W panel in Los Angeles and about 312 kWh in Palmdale (20° roof, facing south, 14% system losses).
With γ = −0.385 %/°C, at a 77 °C cell temperature (hottest modeled hour in Palmdale) output is about 19.9% below the STC rating.