Cali-GrafCali-Graf
Solar panelSun Gold Power

Sun Gold Power SG455WM

108 cells. Power classes 380–550 W in the CEC list.

CEC listed · Aug 1, 2025UL 61730
Power class
  • Power (STC)455 WCEC nameplate
  • Efficiency≈23.9%calculated from area
  • %/°C Pmax−0.339CEC listing test
  • PTC / STC94.8%PTC 431 W (CEC)

Power classes

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation · 30 models
ModelPmaxVoc, VIsc, AVmp, VImp, AEfficiencyPTCCEC listed
SG380WM380 W36.3013.2030.5012.45≈20.0%358 WAug 1, 2025
SG385WM385 W36.4013.3530.6012.60≈20.3%363 WAug 1, 2025
SG390WM390 W36.5013.5030.6012.73≈20.5%368 WAug 1, 2025
SG395WM395 W36.6013.5231.0012.75≈20.8%373 WAug 1, 2025
SG400WM400 W37.3013.5331.4012.76≈21.1%378 WAug 1, 2025
SG405WM405 W37.3013.6831.4012.91≈21.3%383 WAug 1, 2025
SG410WM410 W37.5013.7931.5013.01≈21.6%388 WAug 1, 2025
SG415WM415 W37.6013.9231.6013.13≈21.8%392 WAug 1, 2025
SG420WM420 W37.7014.0731.7013.27≈22.1%397 WAug 1, 2025
SG430WM430 W39.7013.5633.6012.79≈22.6%407 WAug 1, 2025
SG435WM435 W39.7013.7033.7012.93≈22.9%412 WAug 1, 2025
SG440WM440 W39.8013.7333.7013.05≈23.2%417 WAug 1, 2025
SG445WM445 W40.3013.8133.8013.15≈23.4%421 WAug 1, 2025
SG450WM450 W41.7013.8234.2013.16≈23.7%426 WAug 1, 2025
SG455WM455 W41.7014.0634.3013.26≈23.9%431 WAug 1, 2025
SG460WM460 W41.8014.1334.5013.33≈24.2%436 WAug 1, 2025
SG480WM480 W44.1013.7237.1012.94≈25.3%456 WAug 1, 2025
SG485WM485 W44.2013.8537.1013.07≈25.5%460 WAug 1, 2025
SG490WM490 W44.2013.9837.2013.19≈25.8%465 WAug 1, 2025
SG495WM495 W44.4014.0837.3013.28≈26.1%470 WAug 1, 2025
SG500WM500 W44.4014.0937.6013.30≈26.3%475 WAug 1, 2025
SG505WM505 W45.2014.1138.0013.31≈26.6%480 WAug 1, 2025
SG510WM510 W45.4014.1838.1013.38≈26.8%485 WAug 1, 2025
SG520WM520 W48.3013.5740.6012.80≈27.4%495 WAug 1, 2025
SG525WM525 W48.4013.6840.7012.91≈27.6%500 WAug 1, 2025
SG530WM530 W48.6013.7540.9012.97≈27.9%504 WAug 1, 2025
SG535WM535 W48.8013.8441.0013.06≈28.2%509 WAug 1, 2025
SG540WM540 W48.9013.9241.1013.09≈28.4%514 WAug 1, 2025
SG545WM545 W49.5014.0041.6013.10≈28.7%519 WAug 1, 2025
SG550WM550 W49.9014.0142.0013.11≈28.9%524 WAug 1, 2025
≈ efficiency = Pmax ÷ CEC-listed area 1.9 m².

Build & dimensions

CEC PV Module List (Oct 7, 2026)

Heat & cold behaviour

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation
CEC listing test
Pmax coefficient γ−0.339 %/°C
Voc coefficient β−0.259 %/°C
Isc coefficient α+0.050 %/°C
Operating cell temperatureNOCT 42.3 °C
Vmp coefficient ≈ γ − α (CEC); used only for the hot-roof voltage estimate.

Away from lab conditions — CEC listing test points

ClassPmax at NOCTVmp × Imp at NOCTPmax at 200 W/m²Low-light efficiency vs STC
380 W273.8 W28.4 V × 9.64 A——
385 W278.2 W28.5 V × 9.76 A——
390 W281 W28.5 V × 9.86 A——
395 W285.5 W28.9 V × 9.88 A——
400 W288.5 W29.2 V × 9.88 A——
405 W292 W29.2 V × 10 A——
410 W296.4 W29.4 V × 10.08 A——
415 W299 W29.4 V × 10.17 A——
420 W303.3 W29.5 V × 10.28 A——
430 W302.4 W31.4 V × 9.63 A——
435 W305.8 W31.4 V × 9.74 A——
440 W309.6 W31.5 V × 9.83 A——
445 W312.8 W31.6 V × 9.9 A——
450 W316.1 W31.9 V × 9.91 A——
455 W319.7 W32 V × 9.99 A——
460 W323.3 W32.2 V × 10.04 A——
480 W352.5 W35.5 V × 9.93 A——
485 W357.1 W35.6 V × 10.03 A——
490 W360.3 W35.6 V × 10.12 A——
495 W363.8 W35.7 V × 10.19 A——
500 W367.6 W36 V × 10.21 A——
505 W371.6 W36.4 V × 10.21 A——
510 W374.9 W36.5 V × 10.27 A——
520 W375.6 W37.9 V × 9.91 A——
525 W379.6 W38 V × 9.99 A——
530 W382.5 W38.1 V × 10.04 A——
535 W386.2 W38.2 V × 10.11 A——
540 W389 W38.4 V × 10.13 A——
545 W393.4 W38.8 V × 10.14 A——
550 W397.9 W39.2 V × 10.15 A——
Pmax = Vmp × Imp from the CEC listing; low-light efficiency = Pmax at 200 W/m² ÷ (20% of STC Pmax).

Inverter compatibility & string sizing

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation · NLR PVWatts v8 · inverter datasheets · NLR SAM inverter library · CEC Grid Support Inverter List (Oct 7, 2026)
44.2 V
Voc when cold
per panel
27.8 V
Vmp when hot
per panel
13
Max panels / string
max DC 600 V
3
Min panels / string
MPPT from 60 V
Defaults come from NLR TMY weather (coldest hour, hottest modeled cell). Code calculations (NEC 690.7) use the ASHRAE extreme annual minimum, which is usually colder — enter it above. β is the CEC-measured coefficient; NEC 690.7 calculations use the datasheet value.

String inverters most named in SoCal permits

InverterMax DC inputMPPTWindow sourcePanels per string
Tesla 1538000-xx-y600 V60–480 Vdatasheet3–13
Solis (Ginlong) S6-EH1P10K-H-US600 V80–520 Vdatasheet3–13
Solis (Ginlong) Solis-1P7.6K-4G-US600 V100–500 Vdatasheet4–13
Qcells Q.VOLT H7.6SX498 V234–498 VCEC test window9–11

Microinverters (one per panel)

MicroinverterRecommended module powerMax DC inputMPPTVoc cold / Vmp hotCheckDC/AC
Enphase IQ8X-80-M-US320–540 W79.5 V43–60 V44.2 / 27.8 V✗ Not a match: module voltage below MPPT range1.2
APsystems (Alt Power System) DS3-L265–570 W60 V28–45 V44.2 / 27.8 V⚠ Works; below MPPT at peak heat0.58
Enphase IQ8M-72-2-US260–460 W60 V30–45 V44.2 / 27.8 V⚠ Works; below MPPT at peak heat1.4
Enphase IQ8A-72-2-US295–500 W60 V32–45 V44.2 / 27.8 V⚠ Works; below MPPT at peak heat1.3
Voltage check against the microinverter datasheets — confirm the pairing on the manufacturer’s module compatibility list. Rows appear only when the panel’s power is inside the microinverter’s recommended module power range.
SolarEdge and other optimizer-based systems size strings by the optimizer rules — use the manufacturer’s designer. Reference inverters: most named in SoCal permits since Oct 2024.

Expected production in Southern California

NLR PVWatts v8 · Cali-Graf calculation
CitykWh / kW / yrkWh / panel / yrkWh / system / yrSun, kWh/m²/day
Los Angeles1,67676311,4396.08
Palmdale1,83583512,5246.69
Chula Vista1,69677211,5756.11
Huntington Beach1,64374811,2135.89
Riverside1,69677211,5756.21
Santa Clarita1,72478411,7666.28
747Jan747Feb959Mar1,059Apr1,046May1,112Jun1,171Jul1,185Aug1,036Sep914Oct786Nov680DeckWh per month · Los Angeles
Estimate for comparison, not a quote: shading, roof orientation and local losses change real output. Roof mount, 20° tilt, south, 14% system losses.

Compare with similar 455 W panels

CEC PV Module List (Oct 7, 2026) · datasheets · Kiwa PVEL Scorecard · building permits
PanelPmaxEfficiencyγ Pmax (CEC)Voc, VIsc, ASoCal permits (series)
Sun Gold Power SG455WM455 W≈23.9%−0.33941.714.06—
Hyundai Energy Solutions HiN-T450NF(BK)450 W≈23.2%−0.29839.214.5337
REC Group REC455AA Pure-RX455 W≈22.5%−0.24865.68.8433
Aptos Solar DNA-120-MF10-455W455 W≈21%−0.36341.513.9322
Same fields from the same sources for every row; ≈ efficiency is calculated from the listed area. Comparable series: other brands, same product group, power range covering this class.

Questions & answers

How efficient is the Sun Gold Power SG455WM?

Calculated from the panel area (1.9 m²): about 23.9% for the 455 W class. 455 W over 1.9 m² equals about 239 W per square meter.

How much energy does one panel produce in Los Angeles or Palmdale?

PVWatts v8 with typical-year weather gives about 763 kWh per year per 455 W panel in Los Angeles and about 835 kWh in Palmdale (20° roof, facing south, 14% system losses).

How much power does it lose on a hot roof?

With γ = −0.339 %/°C, at a 77 °C cell temperature (hottest modeled hour in Palmdale) output is about 17.6% below the STC rating.

How many panels fit on one string?

With the Tesla 1538000-xx-y (max DC 600 V, MPPT from 60 V, datasheet) in Los Angeles the calculator gives 3–13 panels per string (Voc at 2 °C = 44.2 V, Vmp at 74 °C cell = 27.8 V). Final design must follow the inverter manual and NEC 690.7.

Sources

  1. California Energy Commission — Solar Equipment Lists, PV Module List, Inverter List (snapshot Oct 7, 2026).
  2. Hyundai Energy Solutions — datasheet [US] NF(BK)(HiN) Series (N TOPCon Bifacial) 435~445W.
  3. Aptos Solar — datasheet Legacy Products.
  4. Kiwa PVEL — PV Module Reliability Scorecard, Top Performer lists.
  5. NLR (formerly NREL) — System Advisor Model CEC inverter library (version 2026.7.3).
  6. NLR (formerly NREL) — PVWatts v8, NSRDB PSM v3 typical-year weather for Los Angeles, Palmdale, Chula Vista, Huntington Beach, Riverside, Santa Clarita.
  7. Inverter datasheets — APsystems (Alt Power System), Enphase, Solis (Ginlong), Tesla (manufacturer documents).
  8. Building permits — Southern California permit portals. Equipment matched from permit descriptions.
  9. Cali-Graf calculations — formulas and inputs are shown next to each calculated value (efficiency from area, temperature-corrected voltages, string sizing, energy estimates).