144 half-cut cells, bifacial, glass (dual-glass module). Power classes 545–565 W in the CEC list.
| Model | Pmax | Voc, V | Isc, A | Vmp, V | Imp, A | Efficiency | PTC | CEC listed |
|---|---|---|---|---|---|---|---|---|
| SGP-545-SBD | 545 W | 49.50 | 13.94 | 40.80 | 13.38 | ≈21.1% | 515 W | Sep 22, 2025 |
| SGP-550-SBD | 550 W | 49.60 | 14.04 | 40.80 | 13.48 | ≈21.3% | 520 W | Sep 22, 2025 |
| SGP-555-SBD | 555 W | 49.70 | 14.13 | 40.90 | 13.58 | ≈21.5% | 524 W | Sep 22, 2025 |
| SGP-560-SBD | 560 W | 49.80 | 14.25 | 41.00 | 13.68 | ≈21.7% | 529 W | Sep 22, 2025 |
| SGP-565-SBD | 565 W | 49.80 | 14.37 | 41.00 | 13.78 | ≈21.9% | 534 W | Sep 22, 2025 |
| CEC listing test | |
|---|---|
| Pmax coefficient γ | −0.320 %/°C |
| Voc coefficient β | −0.245 %/°C |
| Isc coefficient α | +0.043 %/°C |
| Operating cell temperature | NOCT 43.4 °C |
| Class | Pmax at NOCT | Vmp × Imp at NOCT | Pmax at 200 W/m² | Low-light efficiency vs STC |
|---|---|---|---|---|
| 545 W | 406.6 W | 40.5 V × 10.04 A | 103.9 W | 95% |
| 550 W | 410.5 W | 40.6 V × 10.11 A | 104.9 W | 95% |
| 555 W | 413.7 W | 40.6 V × 10.19 A | 105.9 W | 95% |
| 560 W | 418 W | 40.7 V × 10.27 A | 106.9 W | 95% |
| 565 W | 421.9 W | 40.8 V × 10.34 A | 107.9 W | 95% |
| Inverter | Max DC input | MPPT | Window source | Panels per string |
|---|---|---|---|---|
| Tesla 1538000-xx-y | 600 V | 60–480 V | datasheet | 2–11 |
| Solis (Ginlong) S6-EH1P10K-H-US | 600 V | 80–520 V | datasheet | 3–11 |
| Solis (Ginlong) Solis-1P7.6K-4G-US | 600 V | 100–500 V | datasheet | 3–11 |
| Qcells Q.VOLT H7.6SX | 498 V | 234–498 V | CEC test window | 7–9 |
| Microinverter | Recommended module power | Max DC input | MPPT | Voc cold / Vmp hot | Check | DC/AC |
|---|---|---|---|---|---|---|
| APsystems (Alt Power System) DS3-L | 265–570 W | 60 V | 28–45 V | 52.5 / 33.6 V | ✓ Within range | 0.71 |
| City | kWh / kW / yr | kWh / panel / yr | kWh / system / yr | Sun, kWh/m²/day |
|---|---|---|---|---|
| Los Angeles | 1,676 | 930 | 12,092 | 6.08 |
| Palmdale | 1,835 | 1,018 | 13,240 | 6.69 |
| Chula Vista | 1,696 | 941 | 12,237 | 6.11 |
| Huntington Beach | 1,643 | 912 | 11,854 | 5.89 |
| Riverside | 1,696 | 941 | 12,237 | 6.21 |
| Santa Clarita | 1,724 | 957 | 12,439 | 6.28 |
| Panel | Pmax | Efficiency | γ Pmax (CEC) | Voc, V | Isc, A | PVEL (product / brand) | SoCal permits (series) |
|---|---|---|---|---|---|---|---|
| Sun Gold Power SGP-555-SBD | 555 W | ≈21.5% | −0.320 | 49.7 | 14.13 | — | — |
| JA Solar JAM72D30-550/MB | 550 W | ≈21.8% | −0.330 | 49.9 | 14 | product 2023, 2024 | 3 |
| LONGi LR5-72HBD-555M | 555 W | ≈21.7% | −0.354 | 49.95 | 14.05 | product 2026 | 1 |
| Canadian Solar CS6W-555MB-AG | 555 W | ≈21.6% | −0.324 | 49.8 | 14.05 | product 2024 | 1 |
Calculated from the panel area (2.58 m²): about 21.5% for the 555 W class. 555 W over 2.58 m² equals about 215 W per square meter.
PVWatts v8 with typical-year weather gives about 930 kWh per year per 555 W panel in Los Angeles and about 1,018 kWh in Palmdale (20° roof, facing south, 14% system losses).
With γ = −0.320 %/°C, at a 77 °C cell temperature (hottest modeled hour in Palmdale) output is about 16.6% below the STC rating.
With the Tesla 1538000-xx-y (max DC 600 V, MPPT from 60 V, datasheet) in Los Angeles the calculator gives 2–11 panels per string (Voc at 2 °C = 52.5 V, Vmp at 74 °C cell = 33.6 V). Final design must follow the inverter manual and NEC 690.7.
Voltage check against the APsystems (Alt Power System) datasheet: Voc when cold 52.5 V vs max input 60 V; Vmp when hot 33.6 V vs MPPT low 28 V; recommended module power 265–570 W. Confirm on the microinverter maker’s compatibility list.
Yes. Rear gain depends on mounting height and ground reflectance.